IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i10p3529-d813625.html
   My bibliography  Save this article

Research Summary and Literature Review on Modelling and Simulation of Heat Pumps for Simultaneous Heating and Cooling for Buildings

Author

Listed:
  • Paul Byrne

    (Laboratoire Génie Civil Génie Mécanique, University of Rennes, 35000 Rennes, France)

Abstract

A heat pump for simultaneous heating and cooling (HPS) is a refrigeration machine by which the productions of heating and cooling energies are simultaneously valorized. This introductory article presents the uses of heat pump productions under the form of an analysis of thermal demands of different types of buildings and a literature review of real installations and experimental systems, which are the basis of the construction of numerical models. The applications of HPSs are diverse: space heating and cooling, domestic hot water (DHW), hot water for desalination process, etc. Means and methods for improving the performance of refrigeration cycles and the management of heat and cold productions are developed, including modeling and simulation. New refrigeration circuit architectures were designed. A focus is paid on refrigerants. Prototypes combining heating-cooling, heating-cooling-DHW and cooling-desalination have been developed, built and tested to validate the models. Even though a strong simultaneity of thermal demands is essential, the results show that HPSs are generally very efficient systems.

Suggested Citation

  • Paul Byrne, 2022. "Research Summary and Literature Review on Modelling and Simulation of Heat Pumps for Simultaneous Heating and Cooling for Buildings," Energies, MDPI, vol. 15(10), pages 1-43, May.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:10:p:3529-:d:813625
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/10/3529/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/10/3529/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Amin, Zakaria Mohd & Hawlader, M.N.A., 2015. "Analysis of solar desalination system using heat pump," Renewable Energy, Elsevier, vol. 74(C), pages 116-123.
    2. Fatouh, M. & Elgendy, E., 2011. "Experimental investigation of a vapor compression heat pump used for cooling and heating applications," Energy, Elsevier, vol. 36(5), pages 2788-2795.
    3. Byrne, Paul & Miriel, Jacques & Lenat, Yves, 2011. "Experimental study of an air-source heat pump for simultaneous heating and cooling – Part 2: Dynamic behaviour and two-phase thermosiphon defrosting technique," Applied Energy, Elsevier, vol. 88(9), pages 3072-3078.
    4. Dae-Uk Shin & Chang-Ho Jeong, 2021. "Energy Savings of Simultaneous Heating and Cooling System According to Indoor Set Temperature Changes in the Comfort Range," Energies, MDPI, vol. 14(22), pages 1-19, November.
    5. Zilio, Claudio & Brown, J. Steven & Schiochet, Giovanni & Cavallini, Alberto, 2011. "The refrigerant R1234yf in air conditioning systems," Energy, Elsevier, vol. 36(10), pages 6110-6120.
    6. Paolo Artuso & Giacomo Tosato & Antonio Rossetti & Sergio Marinetti & Armin Hafner & Krzysztof Banasiak & Silvia Minetto, 2021. "Dynamic Modelling and Validation of an Air-to-Water Reversible R744 Heat Pump for High Energy Demand Buildings," Energies, MDPI, vol. 14(24), pages 1-25, December.
    7. Morosuk, T. & Tsatsaronis, G., 2009. "Advanced exergetic evaluation of refrigeration machines using different working fluids," Energy, Elsevier, vol. 34(12), pages 2248-2258.
    8. Paul Byrne & Pascal Lalanne, 2021. "Parametric Study of a Long-Duration Energy Storage Using Pumped-Hydro and Carbon Dioxide Transcritical Cycles," Energies, MDPI, vol. 14(15), pages 1-13, July.
    9. Byrne, Paul & Miriel, Jacques & Lenat, Yves, 2011. "Experimental study of an air-source heat pump for simultaneous heating and cooling - Part 1: Basic concepts and performance verification," Applied Energy, Elsevier, vol. 88(5), pages 1841-1847, May.
    10. Gong, Guangcai & Chen, Feihu & Su, Huan & Zhou, Jianyong, 2012. "Thermodynamic simulation of condensation heat recovery characteristics of a single stage centrifugal chiller in a hotel," Applied Energy, Elsevier, vol. 91(1), pages 326-333.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Volodymyr Voloshchuk & Paride Gullo & Eugene Nikiforovich, 2023. "Advanced Exergy Analysis of Ultra-Low GWP Reversible Heat Pumps for Residential Applications," Energies, MDPI, vol. 16(2), pages 1-17, January.
    2. Paul Byrne, 2022. "Modelling and Simulation of Heat Pumps for Simultaneous Heating and Cooling, a Special Issue," Energies, MDPI, vol. 15(16), pages 1-2, August.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Paul Byrne, 2022. "Modelling and Simulation of Heat Pumps for Simultaneous Heating and Cooling, a Special Issue," Energies, MDPI, vol. 15(16), pages 1-2, August.
    2. Zhang, Penglei & Wang, Baolong & Shi, Wenxing & Li, Xianting, 2015. "Experimental investigation on two-phase thermosyphon loop with partially liquid-filled downcomer," Applied Energy, Elsevier, vol. 160(C), pages 10-17.
    3. Siviter, J. & Montecucco, A. & Knox, A.R., 2015. "Rankine cycle efficiency gain using thermoelectric heat pumps," Applied Energy, Elsevier, vol. 140(C), pages 161-170.
    4. Ahn, Jae Hwan & Kang, Hoon & Lee, Ho Seong & Jung, Hae Won & Baek, Changhyun & Kim, Yongchan, 2014. "Heating performance characteristics of a dual source heat pump using air and waste heat in electric vehicles," Applied Energy, Elsevier, vol. 119(C), pages 1-9.
    5. Tong, Zhen & Liu, Xiao-Hua & Jiang, Yi, 2017. "Three typical operating states of an R744 two-phase thermosyphon loop," Applied Energy, Elsevier, vol. 206(C), pages 181-192.
    6. Dae-Uk Shin & Chang-Ho Jeong, 2021. "Energy Savings of Simultaneous Heating and Cooling System According to Indoor Set Temperature Changes in the Comfort Range," Energies, MDPI, vol. 14(22), pages 1-19, November.
    7. Lee, Joo Seong & Song, Kang Sub & Ahn, Jae Hwan & Kim, Yongchan, 2015. "Comparison on the transient cooling performances of hybrid ground-source heat pumps with various flow loop configurations," Energy, Elsevier, vol. 82(C), pages 678-685.
    8. Fei Wang & Rijing Zhao & Wenming Xu & Dong Huang & Zhiguo Qu, 2021. "A Heater-Assisted Air Source Heat Pump Air Conditioner to Improve Thermal Comfort with Frost-Retarded Heating and Heat-Uninterrupted Defrosting," Energies, MDPI, vol. 14(9), pages 1-13, May.
    9. Tong, Zhen & Liu, Xiao-Hua & Jiang, Yi, 2017. "Experimental study of the self-regulating performance of an R744 two-phase thermosyphon loop," Applied Energy, Elsevier, vol. 186(P1), pages 1-12.
    10. Liu, X.G. & He, C. & He, C.C. & Chen, J.J. & Zhang, B.J. & Chen, Q.L., 2017. "A new retrofit approach to the absorption-stabilization process for improving energy efficiency in refineries," Energy, Elsevier, vol. 118(C), pages 1131-1145.
    11. Gullo, Paride & Elmegaard, Brian & Cortella, Giovanni, 2016. "Advanced exergy analysis of a R744 booster refrigeration system with parallel compression," Energy, Elsevier, vol. 107(C), pages 562-571.
    12. Kasaeian, Alibakhsh & Hosseini, Seyed Mohsen & Sheikhpour, Mojgan & Mahian, Omid & Yan, Wei-Mon & Wongwises, Somchai, 2018. "Applications of eco-friendly refrigerants and nanorefrigerants: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 96(C), pages 91-99.
    13. Gebreslassie, Berhane H. & Medrano, Marc & Boer, Dieter, 2010. "Exergy analysis of multi-effect water–LiBr absorption systems: From half to triple effect," Renewable Energy, Elsevier, vol. 35(8), pages 1773-1782.
    14. Janghorban Esfahani, Iman & Kang, Yong Tae & Yoo, ChangKyoo, 2014. "A high efficient combined multi-effect evaporation–absorption heat pump and vapor-compression refrigeration part 1: Energy and economic modeling and analysis," Energy, Elsevier, vol. 75(C), pages 312-326.
    15. Min-Ju Jeon, 2021. "Experimental Analysis of the R744/R404A Cascade Refrigeration System with Internal Heat Exchanger. Part 1: Coefficient of Performance Characteristics," Energies, MDPI, vol. 14(18), pages 1-20, September.
    16. Yang, Zhao & Wu, Xi, 2013. "Retrofits and options for the alternatives to HCFC-22," Energy, Elsevier, vol. 59(C), pages 1-21.
    17. Mosaffa, A.H. & Garousi Farshi, L. & Infante Ferreira, C.A. & Rosen, M.A., 2014. "Advanced exergy analysis of an air conditioning system incorporating thermal energy storage," Energy, Elsevier, vol. 77(C), pages 945-952.
    18. Byrne, Paul & Miriel, Jacques & Lenat, Yves, 2011. "Experimental study of an air-source heat pump for simultaneous heating and cooling – Part 2: Dynamic behaviour and two-phase thermosiphon defrosting technique," Applied Energy, Elsevier, vol. 88(9), pages 3072-3078.
    19. Wang, Zhiwen & Xiong, Wei & Ting, David S.-K. & Carriveau, Rupp & Wang, Zuwen, 2016. "Conventional and advanced exergy analyses of an underwater compressed air energy storage system," Applied Energy, Elsevier, vol. 180(C), pages 810-822.
    20. Chen, Jianyong & Havtun, Hans & Palm, Björn, 2015. "Conventional and advanced exergy analysis of an ejector refrigeration system," Applied Energy, Elsevier, vol. 144(C), pages 139-151.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:10:p:3529-:d:813625. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.