IDEAS home Printed from https://ideas.repec.org/a/eee/appene/v189y2017icp133-141.html
   My bibliography  Save this article

Anthracite combustion characteristics and NOx formation of a 300MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system

Author

Listed:
  • Chen, Zhichao
  • Wang, Qingxiang
  • Wang, Bingnan
  • Zeng, Lingyan
  • Che, Miaomiao
  • Zhang, Xin
  • Li, Zhengqi

Abstract

A new combustion system has been applied to a 300MWe down-fired boiler with swirl burners to reduce NOx emissions. The unit provided the introduction of overfire air (OFA) and a decrease in the flow area of the inner and outer secondary air ducts of the swirl burners. Industrial experiments on the retrofitted boiler were performed at different loads. Full-scale measurements of the flue gas temperature distribution in the burner outlet region, the furnace temperature distributions measured by a pyrometer and the local mean gas species concentrations in the region near the sidewall were made at loads of 180, 250, and 300MWe. The results show that the ignition distance increased with decreasing load, especially as the load decreased from 250MWe to 180MWe. At three different loads, the retrofitted coal/air flow could be all ignited in time at a distance in the range of 0.6–1.4m from the burner outlet. Compared with the original combustion system, the ignition distance of the coal/air flow was significantly reduced at a load of 300MWe. In addition, at a load of 300MWe, the temperature of the boiler hopper was much higher than that at loads of 180MWe and 250MWe. Compared with the original combustion system, the upper furnace temperature decreased slowly with increasing measurement height at a load of 300MWe after the retrofit. Measurements of the O2 and CO concentrations in the region near the sidewall indicate that the fullness degree of the coal flame in the furnace at different loads was different. After the retrofit, the reheat steam temperatures reached the design temperature of 541°C at loads of 180MWe and 250MWe, and the average reheat steam temperatures increased by approximately 13°C. Compared with the original combustion system, a significant NOx reduction (more than 40%) at different loads was achieved without increasing the levels of unburnt carbon in the fly ash.

Suggested Citation

  • Chen, Zhichao & Wang, Qingxiang & Wang, Bingnan & Zeng, Lingyan & Che, Miaomiao & Zhang, Xin & Li, Zhengqi, 2017. "Anthracite combustion characteristics and NOx formation of a 300MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system," Applied Energy, Elsevier, vol. 189(C), pages 133-141.
  • Handle: RePEc:eee:appene:v:189:y:2017:i:c:p:133-141
    DOI: 10.1016/j.apenergy.2016.12.063
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306261916318268
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.apenergy.2016.12.063?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Li, Zhengqi & Liu, Guangkui & Zhu, Qunyi & Chen, Zhichao & Ren, Feng, 2011. "Combustion and NOx emission characteristics of a retrofitted down-fired 660Â MWe utility boiler at different loads," Applied Energy, Elsevier, vol. 88(7), pages 2400-2406, July.
    2. Fan, J.R. & Liang, X.H. & Chen, L.H. & Cen, K.F., 1998. "Modeling of NOx emissions from a W-shaped boiler furnace under different operating conditions," Energy, Elsevier, vol. 23(12), pages 1051-1055.
    3. Wang, Qingxiang & Chen, Zhichao & Che, Miaomiao & Zeng, Lingyan & Li, Zhengqi & Song, Minhang, 2016. "Effect of different inner secondary-air vane angles on combustion characteristics of primary combustion zone for a down-fired 300-MWe utility boiler with overfire air," Applied Energy, Elsevier, vol. 182(C), pages 29-38.
    4. Hodžić, Nihad & Kazagić, Anes & Smajević, Izet, 2016. "Influence of multiple air staging and reburning on NOx emissions during co-firing of low rank brown coal with woody biomass and natural gas," Applied Energy, Elsevier, vol. 168(C), pages 38-47.
    5. Franco, Alessandro & Diaz, Ana R., 2009. "The future challenges for “clean coal technologies”: Joining efficiency increase and pollutant emission control," Energy, Elsevier, vol. 34(3), pages 348-354.
    6. Zeinivand, Hamed & Bazdidi-Tehrani, Farzad, 2012. "Influence of stabilizer jets on combustion characteristics and NOx emission in a jet-stabilized combustor," Applied Energy, Elsevier, vol. 92(C), pages 348-360.
    7. Ma, Lun & Fang, Qingyan & Tan, Peng & Zhang, Cheng & Chen, Gang & Lv, Dangzhen & Duan, Xuenong & Chen, Yiping, 2016. "Effect of the separated overfire air location on the combustion optimization and NOx reduction of a 600MWe FW down-fired utility boiler with a novel combustion system," Applied Energy, Elsevier, vol. 180(C), pages 104-115.
    8. Kuang, Min & Li, Zhengqi & Liu, Chunlong & Zhu, Qunyi, 2013. "Experimental study on combustion and NOx emissions for a down-fired supercritical boiler with multiple-injection multiple-staging technology without overfire air," Applied Energy, Elsevier, vol. 106(C), pages 254-261.
    9. Lee, Jong Min & Kim, Dong Won & Kim, Jae Sung, 2011. "Characteristics of co-combustion of anthracite with bituminous coal in a 200-MWe circulating fluidized bed boiler," Energy, Elsevier, vol. 36(9), pages 5703-5709.
    10. Blakemore, F. B. & Davies, C. & Isaac, J. G., 2001. "Effects of changes in the UK energy-demand and environmental legislation on atmospheric pollution by oxides of nitrogen and black smoke," Applied Energy, Elsevier, vol. 68(1), pages 83-117, January.
    11. Kuang, Min & Li, Zhengqi & Zhang, Yan & Chen, Xiachao & Jia, Jinzhao & Zhu, Qunyi, 2012. "Asymmetric combustion characteristics and NOx emissions of a down-fired 300 MWe utility boiler at different boiler loads," Energy, Elsevier, vol. 37(1), pages 580-590.
    12. Liu, Guangkui & Li, Zhengqi & Chen, Zhichao & Zhu, Xingying & Zhu, Qunyi, 2012. "Effect of the anthracite ratio of blended coals on the combustion and NOx emission characteristics of a retrofitted down-fired 660-MWe utility boiler," Applied Energy, Elsevier, vol. 95(C), pages 196-201.
    13. Tan, Houzhang & Niu, Yanqing & Wang, Xuebin & Xu, Tongmo & Hui, Shien, 2011. "Study of optimal pulverized coal concentration in a four-wall tangentially fired furnace," Applied Energy, Elsevier, vol. 88(4), pages 1164-1168, April.
    14. Liu, Yacheng & Fan, Weidong & Li, Yu, 2016. "Numerical investigation of air-staged combustion emphasizing char gasification and gas temperature deviation in a large-scale, tangentially fired pulverized-coal boiler," Applied Energy, Elsevier, vol. 177(C), pages 323-334.
    15. Staiger, B. & Unterberger, S. & Berger, R. & Hein, Klaus R.G., 2005. "Development of an air staging technology to reduce NOx emissions in grate fired boilers," Energy, Elsevier, vol. 30(8), pages 1429-1438.
    16. Li, Sen & Xu, Tongmo & Hui, Shien & Wei, Xiaolin, 2009. "NOx emission and thermal efficiency of a 300Â MWe utility boiler retrofitted by air staging," Applied Energy, Elsevier, vol. 86(9), pages 1797-1803, September.
    17. Li, Zhengqi & Jing, Jianping & Liu, Guangkui & Chen, Zhichao & Liu, Chunlong, 2010. "Measurement of gas species, temperatures, char burnout, and wall heat fluxes in a 200-MWe lignite-fired boiler at different loads," Applied Energy, Elsevier, vol. 87(4), pages 1217-1230, April.
    18. Fan, Weidong & Lin, Zhengchun & Li, Youyi & Zhang, Mingchuan, 2010. "Experimental flow field characteristics of OFA for large-angle counter flow of fuel-rich jet combustion technology," Applied Energy, Elsevier, vol. 87(8), pages 2737-2745, August.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Chen, Zhichao & Wang, Qingxiang & Zhang, Xiaoyan & Zeng, Lingyan & Zhang, Xin & He, Tao & Liu, Tao & Li, Zhengqi, 2017. "Industrial-scale investigations of anthracite combustion characteristics and NOx emissions in a retrofitted 300 MWe down-fired utility boiler with swirl burners," Applied Energy, Elsevier, vol. 202(C), pages 169-177.
    2. Zeng, Guang & Xu, Mingchen & Tu, Yaojie & Li, Zhenwei & Cai, Yongtie & Zheng, Zhimin & Tay, Kunlin & Yang, Wenming, 2020. "Influences of initial coal concentration on ignition behaviors of low-NOx bias combustion technology," Applied Energy, Elsevier, vol. 278(C).
    3. Kuang, Min & Yang, Guohua & Zhu, Qunyi & Ti, Shuguang & Wang, Zhenfeng, 2017. "Effect of burner location on flow-field deflection and asymmetric combustion in a 600MWe supercritical down-fired boiler," Applied Energy, Elsevier, vol. 206(C), pages 1393-1405.
    4. Yafei Zhang & Rui Luo & Yihua Dou & Qulan Zhou, 2018. "Combustion Characteristics and NO x Emission through a Swirling Burner with Adjustable Flaring Angle," Energies, MDPI, vol. 11(8), pages 1-14, August.
    5. Zhang, Qunli & Niu, Yu & Yang, Xiaohu & Sun, Donghan & Xiao, Xin & Shen, Qi & Wang, Gang, 2020. "Experimental study of flue gas condensing heat recovery synergized with low NOx emission system," Applied Energy, Elsevier, vol. 269(C).
    6. Ouyang, Ziqu & Song, Wenhao & Li, Shiyuan & Liu, Jingzhang & Ding, Hongliang, 2020. "Experiment study on NOx emission characteristics of the ultra-low volatile fuel in a 2 MW novel pulverized fuel self-sustained preheating combustor," Energy, Elsevier, vol. 209(C).
    7. Kuang, Min & Wu, Haiqian & Zhu, Qunyi & Ti, Shuguang, 2018. "Establishing an overall symmetrical combustion setup for a 600 MWe supercritical down-fired boiler: A numerical and cold-modeling experimental verification," Energy, Elsevier, vol. 147(C), pages 208-225.
    8. Wu, Haiqian & Kuang, Min & Wang, Jialin & Zhao, Xiaojuan & Yang, Guohua & Ti, Shuguang & Ding, Jieyi, 2020. "Lower-arch location effect on the flow field, coal combustion, and NOx formation characteristics in a cascade-arch, down-fired furnace," Applied Energy, Elsevier, vol. 268(C).
    9. Kuang, Min & Zhu, Qunyi & Ling, Zhongqian & Ti, Shuguang & Li, Zhengqi, 2017. "Improving gas/particle flow deflection and asymmetric combustion of a 600 MWe supercritical down-fired boiler by increasing its upper furnace height," Energy, Elsevier, vol. 127(C), pages 581-593.
    10. Ma, Lun & Fang, Qingyan & Yin, Chungen & Wang, Huajian & Zhang, Cheng & Chen, Gang, 2019. "A novel corner-fired boiler system of improved efficiency and coal flexibility and reduced NOx emissions," Applied Energy, Elsevier, vol. 238(C), pages 453-465.
    11. Ti, Shuguang & Chen, Zhichao & Li, Zhengqi & Kuang, Min & Xu, Guangyin & Lai, Jinping & Wang, Zhenfeng, 2018. "Influence of primary air cone length on combustion characteristics and NOx emissions of a swirl burner from a 0.5 MW pulverized coal-fired furnace with air staging," Applied Energy, Elsevier, vol. 211(C), pages 1179-1189.
    12. Choi, Minsung & Park, Yeseul & Li, Xinzhuo & Kim, Kibeom & Sung, Yonmo & Hwang, Taegam & Choi, Gyungmin, 2021. "Numerical evaluation of pulverized coal swirling flames and NOx emissions in a coal-fired boiler: Effects of co- and counter-swirling flames and coal injection modes," Energy, Elsevier, vol. 217(C).
    13. Jiang, Yu & Lee, Byoung-Hwa & Oh, Dong-Hun & Jeon, Chung-Hwan, 2022. "Influence of various air-staging on combustion and NOX emission characteristics in a tangentially fired boiler under the 50% load condition," Energy, Elsevier, vol. 244(PB).
    14. Wang, Qingxiang & Chen, Zhichao & Wang, Liang & Zeng, Lingyan & Li, Zhengqi, 2018. "Application of eccentric-swirl-secondary-air combustion technology for high-efficiency and low-NOx performance on a large-scale down-fired boiler with swirl burners," Applied Energy, Elsevier, vol. 223(C), pages 358-368.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Wang, Qingxiang & Chen, Zhichao & Che, Miaomiao & Zeng, Lingyan & Li, Zhengqi & Song, Minhang, 2016. "Effect of different inner secondary-air vane angles on combustion characteristics of primary combustion zone for a down-fired 300-MWe utility boiler with overfire air," Applied Energy, Elsevier, vol. 182(C), pages 29-38.
    2. Chen, Zhichao & Wang, Qingxiang & Zhang, Xiaoyan & Zeng, Lingyan & Zhang, Xin & He, Tao & Liu, Tao & Li, Zhengqi, 2017. "Industrial-scale investigations of anthracite combustion characteristics and NOx emissions in a retrofitted 300 MWe down-fired utility boiler with swirl burners," Applied Energy, Elsevier, vol. 202(C), pages 169-177.
    3. Wang, Qingxiang & Chen, Zhichao & Wang, Jiaquan & Zeng, Lingyan & Zhang, Xin & Li, Xiaoguang & Li, Zhengqi, 2018. "Effects of secondary air distribution in primary combustion zone on combustion and NOx emissions of a large-scale down-fired boiler with air staging," Energy, Elsevier, vol. 165(PB), pages 399-410.
    4. Ling, Zhongqian & Ling, Bo & Kuang, Min & Li, Zhengqi & Lu, Ye, 2017. "Comparison of airflow, coal combustion, NOx emissions, and slagging characteristics among three large-scale MBEL down-fired boilers manufactured at different times," Applied Energy, Elsevier, vol. 187(C), pages 689-705.
    5. Wang, Qingxiang & Chen, Zhichao & Han, Hui & Zeng, Lingyan & Li, Zhengqi, 2019. "Experimental characterization of anthracite combustion and NOx emission for a 300-MWe down-fired boiler with a novel combustion system: Influence of primary and vent air distributions," Applied Energy, Elsevier, vol. 238(C), pages 1551-1562.
    6. Wang, Qingxiang & Chen, Zhichao & Wang, Liang & Zeng, Lingyan & Li, Zhengqi, 2018. "Application of eccentric-swirl-secondary-air combustion technology for high-efficiency and low-NOx performance on a large-scale down-fired boiler with swirl burners," Applied Energy, Elsevier, vol. 223(C), pages 358-368.
    7. Kuang, Min & Yang, Guohua & Zhu, Qunyi & Ti, Shuguang & Wang, Zhenfeng, 2017. "Effect of burner location on flow-field deflection and asymmetric combustion in a 600MWe supercritical down-fired boiler," Applied Energy, Elsevier, vol. 206(C), pages 1393-1405.
    8. Kuang, Min & Li, Zhengqi, 2014. "Review of gas/particle flow, coal combustion, and NOx emission characteristics within down-fired boilers," Energy, Elsevier, vol. 69(C), pages 144-178.
    9. Ti, Shuguang & Chen, Zhichao & Li, Zhengqi & Kuang, Min & Xu, Guangyin & Lai, Jinping & Wang, Zhenfeng, 2018. "Influence of primary air cone length on combustion characteristics and NOx emissions of a swirl burner from a 0.5 MW pulverized coal-fired furnace with air staging," Applied Energy, Elsevier, vol. 211(C), pages 1179-1189.
    10. Zhang, Xin & Chen, Zhichao & Hou, Jian & Liu, Zheng & Zeng, Lingyan & Li, Zhengqi, 2022. "Evaluation of wide-range coal combustion performance of a novel down-fired combustion technology based on gas–solid two-phase flow characteristics," Energy, Elsevier, vol. 248(C).
    11. Liu, Guangkui & Chen, Zhichao & Li, Zhengqi & Zong, Qiudong & Zhang, Hao, 2014. "Effect of the arch-supplied over-fire air ratio on gas/solid flow characteristics of a down-fired boiler," Energy, Elsevier, vol. 70(C), pages 95-109.
    12. Zeng, Guang & Xu, Mingchen & Tu, Yaojie & Li, Zhenwei & Cai, Yongtie & Zheng, Zhimin & Tay, Kunlin & Yang, Wenming, 2020. "Influences of initial coal concentration on ignition behaviors of low-NOx bias combustion technology," Applied Energy, Elsevier, vol. 278(C).
    13. Kuang, Min & Li, Zhengqi & Liu, Chunlong & Zhu, Qunyi, 2013. "Experimental study on combustion and NOx emissions for a down-fired supercritical boiler with multiple-injection multiple-staging technology without overfire air," Applied Energy, Elsevier, vol. 106(C), pages 254-261.
    14. Ma, Lun & Fang, Qingyan & Yin, Chungen & Wang, Huajian & Zhang, Cheng & Chen, Gang, 2019. "A novel corner-fired boiler system of improved efficiency and coal flexibility and reduced NOx emissions," Applied Energy, Elsevier, vol. 238(C), pages 453-465.
    15. Wu, Haiqian & Kuang, Min & Wang, Jialin & Zhao, Xiaojuan & Yang, Guohua & Ti, Shuguang & Ding, Jieyi, 2020. "Lower-arch location effect on the flow field, coal combustion, and NOx formation characteristics in a cascade-arch, down-fired furnace," Applied Energy, Elsevier, vol. 268(C).
    16. Wang, Qingxiang & Chen, Zhichao & Li, Liankai & Zeng, Lingyan & Li, Zhengqi, 2020. "Achievement in ultra-low-load combustion stability for an anthracite- and down-fired boiler after applying novel swirl burners: From laboratory experiments to industrial applications," Energy, Elsevier, vol. 192(C).
    17. Jing Wang & Jingchi Yang & Fengling Yang & Fangqin Cheng, 2023. "Numerical and Experimental Investigation of the Decoupling Combustion Characteristics of a Burner with Flame Stabilizer," Energies, MDPI, vol. 16(11), pages 1-20, June.
    18. Ti, Shuguang & Kuang, Min & Wang, Haopeng & Xu, Guangyin & Niu, Cong & Liu, Yannan & Wang, Zhenfeng, 2020. "Experimental combustion characteristics and NOx emissions at 50% of the full load for a 600-MWe utility boiler: Effects of the coal feed rate for various mills," Energy, Elsevier, vol. 196(C).
    19. Kuang, Min & Wu, Haiqian & Zhu, Qunyi & Ti, Shuguang, 2018. "Establishing an overall symmetrical combustion setup for a 600 MWe supercritical down-fired boiler: A numerical and cold-modeling experimental verification," Energy, Elsevier, vol. 147(C), pages 208-225.
    20. Qiao, Yanyu & Li, Song & Jing, Xinjing & Chen, Zhichao & Fan, Subo & Li, Zhengqi, 2022. "Combustion and NOx formation characteristics from a 330 MWe retrofitted anthracite-fired utility boiler with swirl burner under deeply-staged-combustion," Energy, Elsevier, vol. 258(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:189:y:2017:i:c:p:133-141. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.