IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v127y2017icp581-593.html
   My bibliography  Save this article

Improving gas/particle flow deflection and asymmetric combustion of a 600 MWe supercritical down-fired boiler by increasing its upper furnace height

Author

Listed:
  • Kuang, Min
  • Zhu, Qunyi
  • Ling, Zhongqian
  • Ti, Shuguang
  • Li, Zhengqi

Abstract

A solution characterized by lengthening its short upper furnace was put forward for improving the gas/particle flow deflection and asymmetric combustion within a 600 MWe supercritical down-fired boiler. Based on the present design dimensionless upper furnace height CH2 = 0.864, upper furnace was lengthened in turn to CH2 = 1.00, 1.125, and 1.263 so as to form four comparable settings. Accordingly, cold-modeling gas/particle flow experiments and numerical simulations on coal combustion were performed at these settings for confirming the solution and meanwhile recommending a reasonable CH2 setup. Moreover, real-furnace measurements, used to confirm the numerical simulation validity, were carried out under normal full load. Results at the design setting (CH2 = 0.864) show shat a severely deflected gas/particle flow field appears, with (i) the downward gas/particle flow penetrating much deeper in the front-half side than in the rear-half side and (ii) the upward flow fully deflecting towards the front-half side. Consequently, a bad asymmetric combustion pattern with gas temperatures being much higher in the rear-half side than in the front-half side (temperature gap reaching about 300–600 °C) develops, generating poor burnout and high NOx emissions. Additionally, the simulated results are consistent well with the acquired real-furnace data. In comparison with cold-modeling gas/particle flow experiments, the simulated downward gas/particle flow penetrates clearly shallower in a hot environment. Lengthening upper furnace apparently weakens both the experimental and simulated flow-field deflection and meanwhile improves the asymmetric gas velocity distribution in the upper furnace. As CH2 increases to 1.125 and 1.263, both the experimental and simulated flow-field symmetries are acceptable, accompanied by symmetrical gas velocity distribution in the upper furnace, improved burnout rate, and lowered NOx emissions. A comprehensive consideration of symmetrical combustion, high burnout rate, relatively low NOx emissions, and controlled cost for lengthening upper furnace suggests that a reasonable CH2 should be set at 1.125.

Suggested Citation

  • Kuang, Min & Zhu, Qunyi & Ling, Zhongqian & Ti, Shuguang & Li, Zhengqi, 2017. "Improving gas/particle flow deflection and asymmetric combustion of a 600 MWe supercritical down-fired boiler by increasing its upper furnace height," Energy, Elsevier, vol. 127(C), pages 581-593.
  • Handle: RePEc:eee:energy:v:127:y:2017:i:c:p:581-593
    DOI: 10.1016/j.energy.2017.04.002
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544217305649
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2017.04.002?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Ren, Feng & Li, Zhengqi & Liu, Guangkui & Chen, Zhichao & Zhu, Qunyi, 2011. "Combustion and NOx emissions characteristics of a down-fired 660-MWe utility boiler retro-fitted with air-surrounding-fuel concept," Energy, Elsevier, vol. 36(1), pages 70-77.
    2. Park, Hojeong & Kwon, Hyucksoo, 2011. "Effects of consumer subsidy on household fuel switching from coal to cleaner fuels: A case study for anthracites in Korea," Energy Policy, Elsevier, vol. 39(3), pages 1687-1693, March.
    3. Ling, Zhongqian & Ling, Bo & Kuang, Min & Li, Zhengqi & Lu, Ye, 2017. "Comparison of airflow, coal combustion, NOx emissions, and slagging characteristics among three large-scale MBEL down-fired boilers manufactured at different times," Applied Energy, Elsevier, vol. 187(C), pages 689-705.
    4. Lee, Jong Min & Kim, Dong Won & Kim, Jae Sung, 2011. "Characteristics of co-combustion of anthracite with bituminous coal in a 200-MWe circulating fluidized bed boiler," Energy, Elsevier, vol. 36(9), pages 5703-5709.
    5. Liu, Guangkui & Li, Zhengqi & Chen, Zhichao & Zhu, Xingying & Zhu, Qunyi, 2012. "Effect of the anthracite ratio of blended coals on the combustion and NOx emission characteristics of a retrofitted down-fired 660-MWe utility boiler," Applied Energy, Elsevier, vol. 95(C), pages 196-201.
    6. Li, Sen & Xu, Tongmo & Hui, Shien & Wei, Xiaolin, 2009. "NOx emission and thermal efficiency of a 300Â MWe utility boiler retrofitted by air staging," Applied Energy, Elsevier, vol. 86(9), pages 1797-1803, September.
    7. Kuang, Min & Li, Zhengqi & Zhu, Qunyi & Wang, Yang & Chen, Lizhe & Zhang, Yan, 2012. "Experimental gas/particle flow characteristics of a down-fired 600 MWe supercritical utility boiler at different staged-air ratios," Energy, Elsevier, vol. 42(1), pages 411-423.
    8. Kuang, Min & Li, Zhengqi, 2014. "Review of gas/particle flow, coal combustion, and NOx emission characteristics within down-fired boilers," Energy, Elsevier, vol. 69(C), pages 144-178.
    9. Zeng, Lingyan & Song, Minhang & Li, Xiaoguang & Liu, Yibo & Li, Zhengqi & Chen, Zhichao, 2017. "Factors affecting the downward flame depth in a 600 MW down-fired boiler incorporating multiple-injection and multiple-staging technology," Energy, Elsevier, vol. 118(C), pages 333-344.
    10. Fan, Weidong & Li, Youyi & Lin, Zhengchun & Zhang, Mingchuan, 2010. "PDA research on a novel pulverized coal combustion technology for a large utility boiler," Energy, Elsevier, vol. 35(5), pages 2141-2148.
    11. Kuang, Min & Li, Zhengqi & Zhu, Qunyi & Zhang, Yan, 2013. "Performance assessment of staged-air declination in improving asymmetric gas/particle flow characteristics within a down-fired 600 MWe supercritical utility boiler," Energy, Elsevier, vol. 49(C), pages 423-433.
    12. Chen, Zhichao & Wang, Qingxiang & Wang, Bingnan & Zeng, Lingyan & Che, Miaomiao & Zhang, Xin & Li, Zhengqi, 2017. "Anthracite combustion characteristics and NOx formation of a 300MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system," Applied Energy, Elsevier, vol. 189(C), pages 133-141.
    13. Lee, Jong-Min & Kim, Down-Won & Kim, Jae-Sung & Na, Jeong-Geol & Lee, See-Hoon, 2010. "Co-combustion of refuse derived fuel with Korean anthracite in a commercial circulating fluidized bed boiler," Energy, Elsevier, vol. 35(7), pages 2814-2818.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Belošević, Srdjan & Tomanović, Ivan & Crnomarković, Nenad & Milićević, Aleksandar, 2019. "Full-scale CFD investigation of gas-particle flow, interactions and combustion in tangentially fired pulverized coal furnace," Energy, Elsevier, vol. 179(C), pages 1036-1053.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Kuang, Min & Wu, Haiqian & Zhu, Qunyi & Ti, Shuguang, 2018. "Establishing an overall symmetrical combustion setup for a 600 MWe supercritical down-fired boiler: A numerical and cold-modeling experimental verification," Energy, Elsevier, vol. 147(C), pages 208-225.
    2. Ling, Zhongqian & Ling, Bo & Kuang, Min & Li, Zhengqi & Lu, Ye, 2017. "Comparison of airflow, coal combustion, NOx emissions, and slagging characteristics among three large-scale MBEL down-fired boilers manufactured at different times," Applied Energy, Elsevier, vol. 187(C), pages 689-705.
    3. Kuang, Min & Yang, Guohua & Zhu, Qunyi & Ti, Shuguang & Wang, Zhenfeng, 2017. "Effect of burner location on flow-field deflection and asymmetric combustion in a 600MWe supercritical down-fired boiler," Applied Energy, Elsevier, vol. 206(C), pages 1393-1405.
    4. Kuang, Min & Li, Zhengqi, 2014. "Review of gas/particle flow, coal combustion, and NOx emission characteristics within down-fired boilers," Energy, Elsevier, vol. 69(C), pages 144-178.
    5. Wu, Haiqian & Kuang, Min & Wang, Jialin & Zhao, Xiaojuan & Yang, Guohua & Ti, Shuguang & Ding, Jieyi, 2020. "Lower-arch location effect on the flow field, coal combustion, and NOx formation characteristics in a cascade-arch, down-fired furnace," Applied Energy, Elsevier, vol. 268(C).
    6. Liu, Chunlong & Li, Zhengqi & Zeng, Lingyan & Zhang, Qinghua & Hu, Richa & Zhang, Xusheng & Guo, Liang & Huang, Yong & Yang, Xianwei & Chen, Liheng, 2016. "Gas/particle two-phase flow characteristics of a down-fired 350 MWe supercritical utility boiler at different tertiary air ratios," Energy, Elsevier, vol. 102(C), pages 54-64.
    7. Liu, Chunlong & Li, Zhengqi & Jing, Xinjing & Xie, Yiquan & Zhang, Qinghua & Zong, Qiudong, 2014. "Experimental investigation into gas/particle flow in a down-fired 350 MWe supercritical utility boiler at different over-fire air ratios," Energy, Elsevier, vol. 64(C), pages 771-778.
    8. Zhang, Xin & Chen, Zhichao & Hou, Jian & Liu, Zheng & Zeng, Lingyan & Li, Zhengqi, 2022. "Evaluation of wide-range coal combustion performance of a novel down-fired combustion technology based on gas–solid two-phase flow characteristics," Energy, Elsevier, vol. 248(C).
    9. Wang, Qingxiang & Chen, Zhichao & Han, Hui & Zeng, Lingyan & Li, Zhengqi, 2019. "Experimental characterization of anthracite combustion and NOx emission for a 300-MWe down-fired boiler with a novel combustion system: Influence of primary and vent air distributions," Applied Energy, Elsevier, vol. 238(C), pages 1551-1562.
    10. Wang, Qingxiang & Chen, Zhichao & Wang, Liang & Zeng, Lingyan & Li, Zhengqi, 2018. "Application of eccentric-swirl-secondary-air combustion technology for high-efficiency and low-NOx performance on a large-scale down-fired boiler with swirl burners," Applied Energy, Elsevier, vol. 223(C), pages 358-368.
    11. Anufriev, I.S., 2021. "Review of water/steam addition in liquid-fuel combustion systems for NOx reduction: Waste-to-energy trends," Renewable and Sustainable Energy Reviews, Elsevier, vol. 138(C).
    12. Wang, Qingxiang & Chen, Zhichao & Li, Liankai & Zeng, Lingyan & Li, Zhengqi, 2020. "Achievement in ultra-low-load combustion stability for an anthracite- and down-fired boiler after applying novel swirl burners: From laboratory experiments to industrial applications," Energy, Elsevier, vol. 192(C).
    13. Kuang, Min & Li, Zhengqi & Zhu, Qunyi & Zhang, Yan, 2013. "Performance assessment of staged-air declination in improving asymmetric gas/particle flow characteristics within a down-fired 600 MWe supercritical utility boiler," Energy, Elsevier, vol. 49(C), pages 423-433.
    14. Chen, Zhichao & Wang, Qingxiang & Zhang, Xiaoyan & Zeng, Lingyan & Zhang, Xin & He, Tao & Liu, Tao & Li, Zhengqi, 2017. "Industrial-scale investigations of anthracite combustion characteristics and NOx emissions in a retrofitted 300 MWe down-fired utility boiler with swirl burners," Applied Energy, Elsevier, vol. 202(C), pages 169-177.
    15. Chen, Zhichao & Wang, Qingxiang & Wang, Bingnan & Zeng, Lingyan & Che, Miaomiao & Zhang, Xin & Li, Zhengqi, 2017. "Anthracite combustion characteristics and NOx formation of a 300MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system," Applied Energy, Elsevier, vol. 189(C), pages 133-141.
    16. Ling, Zhongqian & Zhou, Hao & Ren, Tao, 2015. "Effect of the flue gas recirculation supply location on the heavy oil combustion and NOx emission characteristics within a pilot furnace fired by a swirl burner," Energy, Elsevier, vol. 91(C), pages 110-116.
    17. Wang, Jialin & Kuang, Min & Zhao, Xiaojuan & Wu, Haiqian & Ti, Shuguang & Chen, Chuyang & Jiao, Long, 2020. "Trends of the low-NOx and high-burnout combustion characteristics in a cascade-arch, W-shaped flame furnace regarding with the staged-air angle," Energy, Elsevier, vol. 212(C).
    18. Wang, Qingxiang & Chen, Zhichao & Che, Miaomiao & Zeng, Lingyan & Li, Zhengqi & Song, Minhang, 2016. "Effect of different inner secondary-air vane angles on combustion characteristics of primary combustion zone for a down-fired 300-MWe utility boiler with overfire air," Applied Energy, Elsevier, vol. 182(C), pages 29-38.
    19. Ma, Lun & Fang, Qingyan & Yin, Chungen & Wang, Huajian & Zhang, Cheng & Chen, Gang, 2019. "A novel corner-fired boiler system of improved efficiency and coal flexibility and reduced NOx emissions," Applied Energy, Elsevier, vol. 238(C), pages 453-465.
    20. Zhang, Xiaoyu & Zhu, Shujun & Zhu, Jianguo & Liu, Yuhua & Zhang, Jiahang & Hui, Jicheng & Ding, Hongliang & Cao, Xiaoyang & Lyu, Qinggang, 2023. "Preheating and combustion characteristics of anthracite under O2/N2, O2/CO2 and O2/CO2/H2O atmospheres," Energy, Elsevier, vol. 274(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:127:y:2017:i:c:p:581-593. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.