IDEAS home Printed from https://ideas.repec.org/a/eee/appene/v187y2017icp717-731.html
   My bibliography  Save this article

An enthalpy-based energy savings estimation method targeting thermal comfort level in naturally ventilated buildings in hot-humid summer zones

Author

Listed:
  • He, Yueer
  • Liu, Meng
  • Kvan, Thomas
  • Peng, Shini

Abstract

This paper examines naturally ventilated buildings in hot and humid summer zones and proposes an air enthalpy-based energy conservation rating method with an emphasis on the combined thermal comfort-ventilation parameters, particularly the impact of humidity and human adaptations on thermal comfort. The new method starts with energy flow analysis to a naturally ventilated room and assessment of thermal comfort accounting for the humidity of the naturally ventilated room as well as the occupants’ adaptability, differing from the PMV models and widely-used adaptive models adopted in existing rating methods. It contributes to designing a well-performed naturally ventilated building by analysing the interplay of climate elements, design features, indoor thermal comfort, and energy consumption for cooling in hot-humid climates. It also gives the access to rate the influence of an estimated energy saving due to natural ventilation on the energy system at a district or national scale. The proposed method is then applied to a naturally ventilated office located in three cities within this particular climatic region of China. The results indicate that natural ventilation is an effective way to improve thermal comfort while maintaining a low cooling energy consumption in hot-humid summer zones. Using natural ventilation could help reduce cooling energy demand by 10–30% compared to not using natural ventilation. Its energy saving potential is strongly affected by the enthalpy of outdoor air, followed by airflow rate. Then, a contrast comparison between the new method based on energy balance and Chinese indoor thermal comfort standard and the conventional method coupling adaptive ASHRAE standard-55 thermal comfort model with sensible heat balance model is carried out. The contrast results validate the considerable impacts of humidity on energy balance analysis and thermal comfort rating. It points out the new method makes improvement of the maximum energy saving potential of naturally ventilated buildings prediction.

Suggested Citation

  • He, Yueer & Liu, Meng & Kvan, Thomas & Peng, Shini, 2017. "An enthalpy-based energy savings estimation method targeting thermal comfort level in naturally ventilated buildings in hot-humid summer zones," Applied Energy, Elsevier, vol. 187(C), pages 717-731.
  • Handle: RePEc:eee:appene:v:187:y:2017:i:c:p:717-731
    DOI: 10.1016/j.apenergy.2016.11.098
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306261916317299
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.apenergy.2016.11.098?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Imessad, K. & Derradji, L. & Messaoudene, N.Ait & Mokhtari, F. & Chenak, A. & Kharchi, R., 2014. "Impact of passive cooling techniques on energy demand for residential buildings in a Mediterranean climate," Renewable Energy, Elsevier, vol. 71(C), pages 589-597.
    2. Homod, Raad Z. & Sahari, Khairul Salleh Mohamed & Almurib, Haider A.F., 2014. "Energy saving by integrated control of natural ventilation and HVAC systems using model guide for comparison," Renewable Energy, Elsevier, vol. 71(C), pages 639-650.
    3. Campaniço, Hugo & Hollmuller, Pierre & Soares, Pedro M.M., 2014. "Assessing energy savings in cooling demand of buildings using passive cooling systems based on ventilation," Applied Energy, Elsevier, vol. 134(C), pages 426-438.
    4. Tong, Zheming & Chen, Yujiao & Malkawi, Ali & Liu, Zhu & Freeman, Richard B., 2016. "Energy saving potential of natural ventilation in China: The impact of ambient air pollution," Applied Energy, Elsevier, vol. 179(C), pages 660-668.
    5. Yao, Runming & Li, Baizhan & Steemers, Koen & Short, Alan, 2009. "Assessing the natural ventilation cooling potential of office buildings in different climate zones in China," Renewable Energy, Elsevier, vol. 34(12), pages 2697-2705.
    6. Chen, Yujiao & Malkawi, Ali & Liu, Zhu & Freeman, Richard Barry & Tong, Zheming, 2016. "Energy Saving Potential of Natural Ventilation in China: The Impact of Ambient Air Pollution," Scholarly Articles 27733689, Harvard University Department of Economics.
    7. Florides, G. A. & Tassou, S. A. & Kalogirou, S. A. & Wrobel, L. C., 2002. "Measures used to lower building energy consumption and their cost effectiveness," Applied Energy, Elsevier, vol. 73(3-4), pages 299-328, November.
    8. Ramponi, Rubina & Angelotti, Adriana & Blocken, Bert, 2014. "Energy saving potential of night ventilation: Sensitivity to pressure coefficients for different European climates," Applied Energy, Elsevier, vol. 123(C), pages 185-195.
    9. Rupp, Ricardo Forgiarini & Ghisi, Enedir, 2014. "What is the most adequate method to assess thermal comfort in hybrid commercial buildings located in hot-humid summer climate?," Renewable and Sustainable Energy Reviews, Elsevier, vol. 29(C), pages 449-462.
    10. Daghigh, R., 2015. "Assessing the thermal comfort and ventilation in Malaysia and the surrounding regions," Renewable and Sustainable Energy Reviews, Elsevier, vol. 48(C), pages 681-691.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Sakiyama, N.R.M. & Carlo, J.C. & Frick, J. & Garrecht, H., 2020. "Perspectives of naturally ventilated buildings: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 130(C).
    2. Kittisak Lohwanitchai & Daranee Jareemit, 2021. "Modeling Energy Efficiency Performance and Cost-Benefit Analysis Achieving Net-Zero Energy Building Design: Case Studies of Three Representative Offices in Thailand," Sustainability, MDPI, vol. 13(9), pages 1-24, May.
    3. Jeongyoon Oh & Taehoon Hong & Hakpyeong Kim & Jongbaek An & Kwangbok Jeong & Choongwan Koo, 2017. "Advanced Strategies for Net-Zero Energy Building: Focused on the Early Phase and Usage Phase of a Building’s Life Cycle," Sustainability, MDPI, vol. 9(12), pages 1-52, December.
    4. He, Yueer & Liu, Meng & Kvan, Thomas & Yan, Lu, 2019. "A quantity-quality-based optimization method for indoor thermal environment design," Energy, Elsevier, vol. 170(C), pages 1261-1278.
    5. Cui, X. & Mohan, B. & Islam, M.R. & Chou, S.K. & Chua, K.J., 2017. "Energy performance evaluation and application of an air treatment system for conditioning building spaces in tropics," Applied Energy, Elsevier, vol. 204(C), pages 1500-1512.
    6. Wang, Xia & Ding, Chao & Zhou, Mao & Cai, Weiguang & Ma, Xianrui & Yuan, Jiachen, 2023. "Assessment of space heating consumption efficiency based on a household survey in the hot summer and cold winter climate zone in China," Energy, Elsevier, vol. 274(C).

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Sakiyama, N.R.M. & Carlo, J.C. & Frick, J. & Garrecht, H., 2020. "Perspectives of naturally ventilated buildings: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 130(C).
    2. Liwei Wen & Kyosuke Hiyama, 2018. "Target Air Change Rate and Natural Ventilation Potential Maps for Assisting with Natural Ventilation Design During Early Design Stage in China," Sustainability, MDPI, vol. 10(5), pages 1-16, May.
    3. Martins, Nuno R. & Carrilho da Graça, Guilherme, 2017. "Impact of outdoor PM2.5 on natural ventilation usability in California’s nondomestic buildings," Applied Energy, Elsevier, vol. 189(C), pages 711-724.
    4. Payam Nejat & Fatemeh Jomehzadeh & Hasanen Mohammed Hussen & John Kaiser Calautit & Muhd Zaimi Abd Majid, 2018. "Application of Wind as a Renewable Energy Source for Passive Cooling through Windcatchers Integrated with Wing Walls," Energies, MDPI, vol. 11(10), pages 1-23, September.
    5. Tong, Zheming & Chen, Yujiao & Malkawi, Ali, 2016. "Defining the Influence Region in neighborhood-scale CFD simulations for natural ventilation design," Applied Energy, Elsevier, vol. 182(C), pages 625-633.
    6. Chen, Yujiao & Tong, Zheming & Wu, Wentao & Samuelson, Holly & Malkawi, Ali & Norford, Leslie, 2019. "Achieving natural ventilation potential in practice: Control schemes and levels of automation," Applied Energy, Elsevier, vol. 235(C), pages 1141-1152.
    7. Tong, Zheming & Chen, Yujiao & Malkawi, Ali, 2017. "Estimating natural ventilation potential for high-rise buildings considering boundary layer meteorology," Applied Energy, Elsevier, vol. 193(C), pages 276-286.
    8. Cui, X. & Mohan, B. & Islam, M.R. & Chou, S.K. & Chua, K.J., 2017. "Energy performance evaluation and application of an air treatment system for conditioning building spaces in tropics," Applied Energy, Elsevier, vol. 204(C), pages 1500-1512.
    9. Julia Lima Toroxel & Sandra Monteiro Silva, 2024. "A Review of Passive Solar Heating and Cooling Technologies Based on Bioclimatic and Vernacular Architecture," Energies, MDPI, vol. 17(5), pages 1-28, February.
    10. Peter Rafaj & Markus Amann, 2018. "Decomposing Air Pollutant Emissions in Asia: Determinants and Projections," Energies, MDPI, vol. 11(5), pages 1-14, May.
    11. Zhang, Shaohui & Guo, Qinxin & Smyth, Russell & Yao, Yao, 2022. "Extreme temperatures and residential electricity consumption: Evidence from Chinese households," Energy Economics, Elsevier, vol. 107(C).
    12. Costanzo, Vincenzo & Yao, Runming & Xu, Tiantian & Xiong, Jie & Zhang, Qiulei & Li, Baizhan, 2019. "Natural ventilation potential for residential buildings in a densely built-up and highly polluted environment. A case study," Renewable Energy, Elsevier, vol. 138(C), pages 340-353.
    13. Tong, Zheming & Chen, Yujiao & Malkawi, Ali & Liu, Zhu & Freeman, Richard B., 2016. "Energy saving potential of natural ventilation in China: The impact of ambient air pollution," Applied Energy, Elsevier, vol. 179(C), pages 660-668.
    14. Boya Zhou & Shaojun Zhang & Ye Wu & Wenwei Ke & Xiaoyi He & Jiming Hao, 2018. "Energy-saving benefits from plug-in hybrid electric vehicles: perspectives based on real-world measurements," Mitigation and Adaptation Strategies for Global Change, Springer, vol. 23(5), pages 735-756, June.
    15. Wei Xue & Qingming Zhan & Qi Zhang & Zhonghua Wu, 2019. "Spatiotemporal Variations of Particulate and Gaseous Pollutants and Their Relations to Meteorological Parameters: The Case of Xiangyang, China," IJERPH, MDPI, vol. 17(1), pages 1-23, December.
    16. Toparlar, Y. & Blocken, B. & Maiheu, B. & van Heijst, G.J.F., 2018. "Impact of urban microclimate on summertime building cooling demand: A parametric analysis for Antwerp, Belgium," Applied Energy, Elsevier, vol. 228(C), pages 852-872.
    17. Chen, Xi & Yang, Hongxing & Wang, Yuanhao, 2017. "Parametric study of passive design strategies for high-rise residential buildings in hot and humid climates: miscellaneous impact factors," Renewable and Sustainable Energy Reviews, Elsevier, vol. 69(C), pages 442-460.
    18. Qing He & Haiyang Zhao & Lin Shen & Liuqun Dong & Ye Cheng & Ke Xu, 2019. "Factors Influencing Residents’ Intention toward Green Retrofitting of Existing Residential Buildings," Sustainability, MDPI, vol. 11(15), pages 1-23, August.
    19. Haolia Rahman & Hwataik Han, 2019. "Correlation of Ventilative Cooling Potentials and Building Energy Savings in Various Climatic Zones," Energies, MDPI, vol. 12(6), pages 1-10, March.
    20. Ádám László Katona & Huang Xuan & Sara Elhadad & István Kistelegdi & István Háber, 2020. "High-Resolution CFD and In-Situ Monitoring Based Validation of an Industrial Passive Air Conduction System (PACS)," Energies, MDPI, vol. 13(12), pages 1-23, June.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:187:y:2017:i:c:p:717-731. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.