IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v28y2003i1p111-127.html
   My bibliography  Save this article

Simplified architectural method for the solar control optimization of awnings and external walls in houses in hot and dry climates

Author

Listed:
  • Gómez-Muñoz, Victor M.
  • Porta-Gándara, Miguel Angel

Abstract

In extremely hot and dry climates, like northwestern Mexico, solar gain reduction in houses using solar passive techniques is important for improving comfort inside the construction and to save costs in electrical cooling during the whole year, because the winter season is also hot in those regions. A new one-dimension method is proposed to analyze the interaction between two common shading devices: awnings and external walls to reduce insulation on the facade and inside the house due to fenestration. The method is demonstrated by optimizing a typical dwelling with an azimuth of 90° (east), which, achieves 45% reduction in direct solar insulation during the summer solstice on the profile of the facade. Results showed that this method is simple and reliable in increasing the shadow on the facade and to block completely the solar beam radiation on the windowpane with optimal relations between these shading devices.

Suggested Citation

  • Gómez-Muñoz, Victor M. & Porta-Gándara, Miguel Angel, 2003. "Simplified architectural method for the solar control optimization of awnings and external walls in houses in hot and dry climates," Renewable Energy, Elsevier, vol. 28(1), pages 111-127.
  • Handle: RePEc:eee:renene:v:28:y:2003:i:1:p:111-127
    DOI: 10.1016/S0960-1481(02)00014-9
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148102000149
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/S0960-1481(02)00014-9?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Bojić, M. & Lukić, N., 2000. "Numerical evaluation of solar-energy use through passive heating of weekend houses in Yugoslavia," Renewable Energy, Elsevier, vol. 20(2), pages 207-222.
    2. Blasco Lucas, I & Hoesé, L & Pontoriero, D, 2000. "Experimental study of passive systems thermal performance," Renewable Energy, Elsevier, vol. 19(1), pages 39-45.
    3. Yang, Hongxing & Zhu, Zuojin & Burnett, John, 2000. "Simulation of the behaviour of transparent insulation materials in buildings in northern China," Applied Energy, Elsevier, vol. 67(3), pages 293-306, November.
    4. Raeissi, S. & Taheri, M., 2000. "Skytherm: an approach to year-round thermal energy sufficient houses," Renewable Energy, Elsevier, vol. 19(4), pages 527-543.
    5. Datta, Gouri, 2001. "Effect of fixed horizontal louver shading devices on thermal perfomance of building by TRNSYS simulation," Renewable Energy, Elsevier, vol. 23(3), pages 497-507.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Quesada, Guillermo & Rousse, Daniel & Dutil, Yvan & Badache, Messaoud & Hallé, Stéphane, 2012. "A comprehensive review of solar facades. Opaque solar facades," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(5), pages 2820-2832.
    2. Wang, Weimin & Fernandez, Nick & Katipamula, Srinivas & Alvine, Kyle, 2018. "Performance assessment of a photonic radiative cooling system for office buildings," Renewable Energy, Elsevier, vol. 118(C), pages 265-277.
    3. Taveres-Cachat, Ellika & Lobaccaro, Gabriele & Goia, Francesco & Chaudhary, Gaurav, 2019. "A methodology to improve the performance of PV integrated shading devices using multi-objective optimization," Applied Energy, Elsevier, vol. 247(C), pages 731-744.
    4. Spanaki, Artemisia & Tsoutsos, Theocharis & Kolokotsa, Dionysia, 2011. "On the selection and design of the proper roof pond variant for passive cooling purposes," Renewable and Sustainable Energy Reviews, Elsevier, vol. 15(8), pages 3523-3533.
    5. Binju P Raj & Chandan Swaroop Meena & Nehul Agarwal & Lohit Saini & Shabir Hussain Khahro & Umashankar Subramaniam & Aritra Ghosh, 2021. "A Review on Numerical Approach to Achieve Building Energy Efficiency for Energy, Economy and Environment (3E) Benefit," Energies, MDPI, vol. 14(15), pages 1-26, July.
    6. Ángel Gómez-Moreno & Pedro José Casanova-Peláez & José Manuel Palomar-Carnicero & Fernando Cruz-Peragón, 2016. "Modeling and Experimental Validation of a Low-Cost Radiation Sensor Based on the Photovoltaic Effect for Building Applications," Energies, MDPI, vol. 9(11), pages 1-16, November.
    7. Oliveti, Giuseppe & Arcuri, Natale & De Simone, Marilena & Bruno, Roberto, 2012. "Solar heat gains and operative temperature in attached sunspaces," Renewable Energy, Elsevier, vol. 39(1), pages 241-249.
    8. Stevanović, Sanja, 2013. "Optimization of passive solar design strategies: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 25(C), pages 177-196.
    9. Kuo-Tsang Huang & Kevin Fong-Rey Liu & Han-Hsi Liang, 2015. "Design and Energy Performance of a Buoyancy Driven Exterior Shading Device for Building Application in Taiwan," Energies, MDPI, vol. 8(4), pages 1-23, March.
    10. Lukić, N., 2005. "The transient house heating condition—the daily changes of the building envelope response factor (BER)," Renewable Energy, Elsevier, vol. 30(4), pages 537-549.
    11. Rouhollahi, Mina & Whaley, David & Behrend, Monica & Byrne, Josh & Boland, John, 2022. "The role of residential tree arrangement: A scoping review of energy efficiency in temperate to subtropical climate zones," Renewable and Sustainable Energy Reviews, Elsevier, vol. 158(C).
    12. Danijela Nikolic & Slobodan Djordjevic & Jasmina Skerlic & Jasna Radulovic, 2020. "Energy Analyses of Serbian Buildings with Horizontal Overhangs: A Case Study," Energies, MDPI, vol. 13(17), pages 1-20, September.
    13. Saari, Arto & Kalamees, Targo & Jokisalo, Juha & Michelsson, Rasmus & Alanne, Kari & Kurnitski, Jarek, 2012. "Financial viability of energy-efficiency measures in a new detached house design in Finland," Applied Energy, Elsevier, vol. 92(C), pages 76-83.
    14. Li, He & Jia, Hongwei & Zhong, Ke & Zhai, Zhiqiang (John), 2021. "Analysis of factors influencing actual absorption of solar energy by building walls," Energy, Elsevier, vol. 215(PB).
    15. Jadwiga Świrska-Perkowska & Andrzej Kucharczyk & Jerzy Wyrwał, 2020. "Energy Efficiency of a Solar Wall with Transparent Insulation in Polish Climatic Conditions," Energies, MDPI, vol. 13(4), pages 1-21, February.
    16. Kalogirou, Soteris A. & Bojic, Milorad, 2000. "Artificial neural networks for the prediction of the energy consumption of a passive solar building," Energy, Elsevier, vol. 25(5), pages 479-491.
    17. Kyung Sun Lee & Ki Jun Han & Jae Wook Lee, 2017. "The Impact of Shading Type and Azimuth Orientation on the Daylighting in a Classroom–Focusing on Effectiveness of Façade Shading, Comparing the Results of DA and UDI," Energies, MDPI, vol. 10(5), pages 1-20, May.
    18. Bojić, M., 2000. "Optimization of heating and cooling of a building by employing refuse and renewable energy," Renewable Energy, Elsevier, vol. 20(4), pages 453-465.
    19. Kirimtat, Ayca & Koyunbaba, Basak Kundakci & Chatzikonstantinou, Ioannis & Sariyildiz, Sevil, 2016. "Review of simulation modeling for shading devices in buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 53(C), pages 23-49.
    20. Sehyun Tak & Soomin Woo & Jiyoung Park & Sungjin Park, 2017. "Effect of the Changeable Organic Semi-Transparent Solar Cell Window on Building Energy Efficiency and User Comfort," Sustainability, MDPI, vol. 9(6), pages 1-14, June.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:28:y:2003:i:1:p:111-127. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.