Abstract
Securing the power grid is of extreme concern to many nations as power infrastructure has become integral to modern life and society. A high-altitude electromagnetic pulse (HEMP) is generated by a nuclear detonation high in the atmosphere, producing a powerful electromagnetic field that can damage or destroy electronic devices over a wide area. Protecting against HEMP attacks (insults) requires knowledge of the problem’s bounds before the problem can be appropriately solved. This paper presents a collection of analyses to determine the basic requirements for controller placements on a power grid. Two primary analyses are conducted. The first is an inverted controllability analysis in which the HEMP event is treated as an unbounded control input to the system. Considering the HEMP insult as a controller, we can break down controllability to reduce its influence on the system. The analysis indicates that either all but one neutral path to ground must be protected or that all transmission lines should be secured. However, further exploration of the controllability definition suggests that fewer blocking devices are sufficient for effective HEMP mitigation. The second analysis involves observability to identify the minimum number of sensors needed for full-state feedback. The results show that only one state sensor is required to achieve full-state feedback for the system. These requirements suggest that there is room to optimize controller design and placement to minimize total controller count on a power grid to ensure HEMP mitigation. As an example, the Horton et al. system model with 15 transformers and 15 transmission lines is used to provide a baseline comparison for future optimization studies by running all permutations of neutral and transmission line blocking cases. The minimum number of neutral controllers is 8, which is approximately half of the bounding solution of 14. The minimum number of transmission line controllers is 3, which is one-fifth of the bounding solution of 15 and less than half of the required neutral controllers.
Suggested Citation
Connor A. Lehman & Rush D. Robinett & Wayne W. Weaver & David G. Wilson, 2025.
"Bounding Case Requirements for Power Grid Protection Against High-Altitude Electromagnetic Pulses,"
Energies, MDPI, vol. 18(10), pages 1-21, May.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:10:p:2614-:d:1658859
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:10:p:2614-:d:1658859. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.