IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v11y2017i1p72-d124810.html
   My bibliography  Save this article

A Liquid Desiccant Enhanced Two Stage Evaporative Cooling System—Development and Performance Evaluation of a Test Rig

Author

Listed:
  • M. Mujahid Rafique

    (Department of Mechanical Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia
    Independent Scholar, Toba Tek Singh 36050, Pakistan)

  • Shafiqur Rehman

    (Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia)

  • Luai M. Alhems

    (Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia)

  • Muhammad Ali Shakir

    (Department of Mechanical Engineering, University College of Engineering and Technology, University of Sargodha, Sargodha 40100, Pakistan)

Abstract

Desiccant technology is found to be a good alternative to conventional cooling systems. It can provide better thermal comfort under hot and humid climatic conditions. The major component of a liquid desiccant cooling system is the desiccant dehumidifier which controls the latent cooling load. In this paper, a newly developed liquid desiccant enhanced evaporative cooling system has been tested experimentally. The effects of ambient conditions and other parameters on the performance of the system are investigated. The system performance curves which help to determine the air outlet conditions and coefficient of performance (COP) of the system are drawn for a wide range of ambient air humidity ratios (0.010–0.026 kg/kg), ambient air temperature (25–40 °C), process air flow rate (1.5–8.0 kg/m 2 ·s), regeneration air flow rate (1.5–4.5 kg/m 2 ·s), and regeneration temperature (55–85 °C). The results showed that better supply air conditions are achieved for hot and humid climatic conditions with effectiveness of the system largely dependent on process and regeneration air flow rates, regeneration temperature, and humidity ratio of process air. The dehumidification performance is increased by 62% for a change of ambient air humidity ratio from 0.01 to 0.025 kg/kg. The thermal coefficient of performance improved by 50% for the above variation in humidity ratio. This shows that such thermally activated systems are feasible options for hot and humid climatic conditions as indicated by better performance under these conditions.

Suggested Citation

  • M. Mujahid Rafique & Shafiqur Rehman & Luai M. Alhems & Muhammad Ali Shakir, 2017. "A Liquid Desiccant Enhanced Two Stage Evaporative Cooling System—Development and Performance Evaluation of a Test Rig," Energies, MDPI, vol. 11(1), pages 1-17, December.
  • Handle: RePEc:gam:jeners:v:11:y:2017:i:1:p:72-:d:124810
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/11/1/72/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/11/1/72/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Angrisani, Giovanni & Roselli, Carlo & Sasso, Maurizio, 2013. "Effect of rotational speed on the performances of a desiccant wheel," Applied Energy, Elsevier, vol. 104(C), pages 268-275.
    2. Tashtoush, Bourhan & Tahat, Mahmood & Al-Hayajneh, Ahmed & Mazur, Victor A. & Probert, Doug, 2001. "Thermodynamic behaviour of an air-conditioning system employing combined evaporative-water and air coolers," Applied Energy, Elsevier, vol. 70(4), pages 305-319, December.
    3. Mujahid Rafique, M. & Gandhidasan, P. & Rehman, Shafiqur & Al-Hadhrami, Luai M., 2015. "A review on desiccant based evaporative cooling systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 45(C), pages 145-159.
    4. Rafique, M. Mujahid & Gandhidasan, P. & Bahaidarah, Haitham M.S., 2016. "Liquid desiccant materials and dehumidifiers – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 56(C), pages 179-195.
    5. Yunlong Ma & Suvash C. Saha & Wendy Miller & Lisa Guan, 2017. "Parametric Analysis of Design Parameter Effects on the Performance of a Solar Desiccant Evaporative Cooling System in Brisbane, Australia," Energies, MDPI, vol. 10(7), pages 1-22, June.
    6. M. Mujahid Rafique & Shafiqur Rehman & Luai M. Alhems & Aref Lashin, 2016. "Parametric Analysis of a Rotary Type Liquid Desiccant Air Conditioning System," Energies, MDPI, vol. 9(4), pages 1-15, April.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Fekadu, Geleta & Subudhi, Sudhakar, 2018. "Renewable energy for liquid desiccants air conditioning system: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 93(C), pages 364-379.
    2. Cui, Yuanlong & Zhu, Jie & Zoras, Stamatis & Liu, Lin, 2021. "Review of the recent advances in dew point evaporative cooling technology: 3E (energy, economic and environmental) assessments," Renewable and Sustainable Energy Reviews, Elsevier, vol. 148(C).
    3. Giampieri, Alessandro & Ma, Zhiwei & Smallbone, Andrew & Roskilly, Anthony Paul, 2018. "Thermodynamics and economics of liquid desiccants for heating, ventilation and air-conditioning – An overview," Applied Energy, Elsevier, vol. 220(C), pages 455-479.
    4. Lanbo Lai & Xiaolin Wang & Gholamreza Kefayati & Eric Hu, 2021. "Evaporative Cooling Integrated with Solid Desiccant Systems: A Review," Energies, MDPI, vol. 14(18), pages 1-23, September.
    5. Yang, Yifan & Cui, Gary & Lan, Christopher Q., 2019. "Developments in evaporative cooling and enhanced evaporative cooling - A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 113(C), pages 1-1.
    6. Yunlong Ma & Suvash C. Saha & Wendy Miller & Lisa Guan, 2017. "Comparison of Different Solar-Assisted Air Conditioning Systems for Australian Office Buildings," Energies, MDPI, vol. 10(10), pages 1-27, September.
    7. Shafiqur Rehman & Muhammad M. Rafique & Luai M. Alhems & Md. Mahbub Alam, 2020. "Development and Implementation of Solar Assisted Desiccant Cooling Technology in Developing Countries: A Case of Saudi Arabia," Energies, MDPI, vol. 13(3), pages 1-22, January.
    8. Luo, Jielin & Yang, Hongxing, 2022. "A state-of-the-art review on the liquid properties regarding energy and environmental performance in liquid desiccant air-conditioning systems," Applied Energy, Elsevier, vol. 325(C).
    9. Chen, Chih-Hao & Hsu, Chien-Yeh & Chen, Chih-Chieh & Chiang, Yuan-Ching & Chen, Sih-Li, 2016. "Silica gel/polymer composite desiccant wheel combined with heat pump for air-conditioning systems," Energy, Elsevier, vol. 94(C), pages 87-99.
    10. Angrisani, Giovanni & Roselli, Carlo & Sasso, Maurizio, 2015. "Experimental assessment of the energy performance of a hybrid desiccant cooling system and comparison with other air-conditioning technologies," Applied Energy, Elsevier, vol. 138(C), pages 533-545.
    11. Gao, D.C. & Sun, Y.J. & Ma, Z. & Ren, H., 2021. "A review on integration and design of desiccant air-conditioning systems for overall performance improvements," Renewable and Sustainable Energy Reviews, Elsevier, vol. 141(C).
    12. Speerforck, Arne & Schmitz, Gerhard, 2016. "Experimental investigation of a ground-coupled desiccant assisted air conditioning system," Applied Energy, Elsevier, vol. 181(C), pages 575-585.
    13. Kashish Kumar & Alok Singh, 2022. "Economic and Experimental Assessment of KCOOH Hybrid Liquid Desiccant-Vapor Compression System," Sustainability, MDPI, vol. 14(23), pages 1-25, November.
    14. Anatolijs Borodinecs & Kristina Lebedeva & Natalja Sidenko & Aleksejs Prozuments, 2022. "Enhancement of Chiller Performance by Water Distribution on the Adiabatic Cooling Pad’s Mesh Surface," Clean Technol., MDPI, vol. 4(3), pages 1-19, July.
    15. Zhuang, Chaoqun & Wang, Shengwei & Shan, Kui, 2019. "Adaptive full-range decoupled ventilation strategy and air-conditioning systems for cleanrooms and buildings requiring strict humidity control and their performance evaluation," Energy, Elsevier, vol. 168(C), pages 883-896.
    16. Mohammad, Abdulrahman Th. & Bin Mat, Sohif & Sulaiman, M.Y. & Sopian, K. & Al-abidi, Abduljalil A., 2013. "Survey of hybrid liquid desiccant air conditioning systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 20(C), pages 186-200.
    17. Liu, Hongdou & Yang, Hongquan & Qi, Ronghui, 2020. "A review of electrically driven dehumidification technology for air-conditioning systems," Applied Energy, Elsevier, vol. 279(C).
    18. Bui, Duc Thuan & Kum Ja, M. & Gordon, Jeffrey M. & Ng, Kim Choon & Chua, Kian Jon, 2017. "A thermodynamic perspective to study energy performance of vacuum-based membrane dehumidification," Energy, Elsevier, vol. 132(C), pages 106-115.
    19. Gurubalan, A. & Maiya, M.P. & Geoghegan, Patrick J., 2019. "A comprehensive review of liquid desiccant air conditioning system," Applied Energy, Elsevier, vol. 254(C).
    20. Tu, Min & Huang, Hui & Liu, Ze-Hua & Chen, Huan-Xin & Ren, Cheng-Qin & Chen, Guo-Jie & Hu, Yan, 2017. "Factor analysis and optimization of operational parameters in a liquid desiccant air-conditioning system," Energy, Elsevier, vol. 139(C), pages 767-781.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:11:y:2017:i:1:p:72-:d:124810. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.