Evaluation of the impacts of high stage refrigerant charge on cascade heat pump performance

Author

Listed:
  • Chae, Jung-Hoon
  • Choi, Jong Min

Abstract

Heat pump systems offer economical alternatives for recovering heat from different sources for use in domestic and industrial refrigeration, space heating, and air conditioning. Some of these domestic and industrial applications require very low evaporating temperatures and very high condensing temperatures which induce high compressor pressure ratios beyond the practical range for single-stage heat pump cycles. This challenge can be overcome by adopting cascade heat pump cycles. In this study, a water-to-water cascade heat pump is tested to investigate the effects of high stage refrigerant charge amount on the performance in a steady state and heating mode operation. The temperature difference between the condensing temperature of the LS cycle and the evaporating temperature of the HS cycle at cascade heat exchanger was increased by reducing the HS refrigerant charge amount, while the heat transfer rate between HS and LS cycles decreased due to a decreasing of refrigerant flow rate. Finally, COP showed lower value at the undercharged condition than that at the fully charged condition. The slope of the capacity with a HS charge amount was much steeper at undercharged conditions than that at overcharged conditions. For HS undercharged conditions, the heating capacity decreased greatly, because heat transfer rate from LS cycle to HS cycle reduced.

Suggested Citation

  • Chae, Jung-Hoon & Choi, Jong Min, 2015. "Evaluation of the impacts of high stage refrigerant charge on cascade heat pump performance," Renewable Energy, Elsevier, vol. 79(C), pages 66-71.
  • Handle: RePEc:eee:renene:v:79:y:2015:i:c:p:66-71
    DOI: 10.1016/j.renene.2014.07.042
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148114004406
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2014.07.042?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Choi, J.M & Kim, Y.C, 2002. "The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube," Energy, Elsevier, vol. 27(4), pages 391-404.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Samuel Boahen & Kwang Ho Lee & Jong Min Choi, 2019. "Refrigerant Charge Fault Detection and Diagnosis Algorithm for Water-to-Water Heat Pump Unit," Energies, MDPI, vol. 12(3), pages 1-25, February.
    2. Minglu, Qu & Rao, Zhang & Jianbo, Chen & Yuanda, Cheng & Xudong, Zhao & Tongyao, Zhang & Zhao, Li, 2020. "Experimental analysis of heat coupling during TES based reverse cycle defrosting method for cascade air source heat pumps," Renewable Energy, Elsevier, vol. 147(P1), pages 35-42.
    3. Gao, Peng & Shao, Liang-Liang & Zhang, Chun-Lu, 2019. "Pressure boost thermochemical sorption heat pump cycle," Energy, Elsevier, vol. 169(C), pages 1090-1100.
    4. Kang Li & Jun Yu & Mingkang Liu & Dan Xu & Lin Su & Yidong Fang, 2020. "A Study of Optimal Refrigerant Charge Amount Determination for Air-Conditioning Heat Pump System in Electric Vehicles," Energies, MDPI, vol. 13(3), pages 1-18, February.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Bolaji, B.O., 2010. "Experimental study of R152a and R32 to replace R134a in a domestic refrigerator," Energy, Elsevier, vol. 35(9), pages 3793-3798.
    2. Park, Young Sung & Jeong, Ji Hwan & Ahn, Byoung Ha, 2014. "Heat pump control method based on direct measurement of evaporation pressure to improve energy efficiency and indoor air temperature stability at a low cooling load condition," Applied Energy, Elsevier, vol. 132(C), pages 99-107.
    3. Jun Kwon Hwang & Patrick Nzivugira Duhirwe & Geun Young Yun & Sukho Lee & Hyeongjoon Seo & Inhan Kim & Mat Santamouris, 2020. "A Novel Hybrid Deep Neural Network Model to Predict the Refrigerant Charge Amount of Heat Pumps," Sustainability, MDPI, vol. 12(7), pages 1-23, April.
    4. Qu, Minglu & Xia, Liang & Deng, Shiming & Jiang, Yiqiang, 2012. "An experimental investigation on reverse-cycle defrosting performance for an air source heat pump using an electronic expansion valve," Applied Energy, Elsevier, vol. 97(C), pages 327-333.
    5. Belman-Flores, J.M. & Barroso-Maldonado, J.M. & Rodríguez-Muñoz, A.P. & Camacho-Vázquez, G., 2015. "Enhancements in domestic refrigeration, approaching a sustainable refrigerator – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 51(C), pages 955-968.
    6. Ze Zhang & Xiaojun Dong & Zheng Ren & Tianwei Lai & Yu Hou, 2017. "Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO 2 Heat Pump Water Heater," Energies, MDPI, vol. 10(10), pages 1-14, October.
    7. Kang Li & Jun Yu & Mingkang Liu & Dan Xu & Lin Su & Yidong Fang, 2020. "A Study of Optimal Refrigerant Charge Amount Determination for Air-Conditioning Heat Pump System in Electric Vehicles," Energies, MDPI, vol. 13(3), pages 1-18, February.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:79:y:2015:i:c:p:66-71. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.