IDEAS home Printed from https://ideas.repec.org/a/eee/appene/v240y2019icp744-753.html
   My bibliography  Save this article

Dynamic modeling of liquid-desiccant regenerator based on a state–space method

Author

Listed:
  • Liu, Wei
  • Gong, Yanfeng
  • Niu, Xiaofeng
  • Shen, Junjie
  • Kosonen, Risto

Abstract

The regenerator is the main energy-consuming component in a liquid-desiccant-based air-conditioning system. Highly efficient control of a regenerator in dynamic operating conditions can improve system performance and reduce system energy consumption. An accurate and reliable dynamic model of a regenerator is fundamental to understand its dynamic operation characteristics and design in a high-performance control system. In this study, a state–space based model of the dynamic operation characteristics of a liquid-desiccant regenerator was developed from the control point of view. In the modeling process, the relationship between the input and output variables was reflected by constructed state–space matrixes. An experimental validation of the proposed dynamic regenerator model showed the dynamic responses of the following three case studies: (1) increase of mass flow rate of inlet desiccant solution, (2) increase in inlet desiccant solution temperature, and (3) increase in inlet air temperature and humidity. The proposed state–space model accurately reflected the dynamic response process of regeneration under different disturbances and initial conditions. Comparison between the modeling and experimental results showed that the relative errors of the outlet air temperature/humidity and outlet desiccant solution temperature were less than 5%, and the mean relative errors of their variations were less than 15%, which validates the accuracy and reliability of the proposed state–space regenerator model. This novel model can be useful for further research on the dynamic operation characteristics of regenerators and the development of high-performance control systems.

Suggested Citation

  • Liu, Wei & Gong, Yanfeng & Niu, Xiaofeng & Shen, Junjie & Kosonen, Risto, 2019. "Dynamic modeling of liquid-desiccant regenerator based on a state–space method," Applied Energy, Elsevier, vol. 240(C), pages 744-753.
  • Handle: RePEc:eee:appene:v:240:y:2019:i:c:p:744-753
    DOI: 10.1016/j.apenergy.2019.02.082
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306261919303824
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.apenergy.2019.02.082?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Wang, Xinli & Cai, Wenjian & Yin, Xiaohong, 2017. "A global optimized operation strategy for energy savings in liquid desiccant air conditioning using self-adaptive differential evolutionary algorithm," Applied Energy, Elsevier, vol. 187(C), pages 410-423.
    2. Wu, Qiong & Cai, WenJian & Shen, Suping & Wang, Xinli & Ren, Haoren, 2017. "A regulation strategy of working concentration in the dehumidifier of liquid desiccant air conditioner," Applied Energy, Elsevier, vol. 202(C), pages 648-661.
    3. Song, Xia & Zhang, Lun & Zhang, Xiaosong, 2018. "NTUm-based optimization of heat or heat pump driven liquid desiccant dehumidification systems regenerated by fresh air or return air," Energy, Elsevier, vol. 158(C), pages 269-280.
    4. Su, Bosheng & Han, Wei & Sui, Jun & Jin, Hongguang, 2017. "A two-stage liquid desiccant dehumidification system by the cascade utilization of low-temperature heat for industrial applications," Applied Energy, Elsevier, vol. 207(C), pages 643-653.
    5. Wu, Wei & Li, Xianting & You, Tian & Wang, Baolong & Shi, Wenxing, 2015. "Combining ground source absorption heat pump with ground source electrical heat pump for thermal balance, higher efficiency and better economy in cold regions," Renewable Energy, Elsevier, vol. 84(C), pages 74-88.
    6. Kabeel, A.E. & Khalil, A. & Elsayed, S.S. & Alatyar, A.M., 2018. "Dynamic behaviour simulation of a liquid desiccant dehumidification system," Energy, Elsevier, vol. 144(C), pages 456-471.
    7. Lu, Hao & Lu, Lin & Luo, Yimo & Qi, Ronghui, 2016. "Investigation on the dynamic characteristics of the counter-current flow for liquid desiccant dehumidification," Energy, Elsevier, vol. 101(C), pages 229-238.
    8. Zhang, Ning & Yin, Shao-You & Zhang, Li-Zhi, 2016. "Performance study of a heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system," Applied Energy, Elsevier, vol. 179(C), pages 727-737.
    9. Mohammad, Abdulrahman Th. & Mat, Sohif Bin & Sopian, K. & Al-abidi, Abduljalil A., 2016. "Review: Survey of the control strategy of liquid desiccant systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 250-258.
    10. Li, Xian & Liu, Shuai & Tan, Kok Kiong & Wang, Qing-Guo & Cai, Wen-Jian & Xie, Lihua, 2016. "Dynamic modeling of a liquid desiccant dehumidifier," Applied Energy, Elsevier, vol. 180(C), pages 435-445.
    11. Zhang, Ning & Yin, Shao-You & Li, Min, 2018. "Model-based optimization for a heat pump driven and hollow fiber membrane hybrid two-stage liquid desiccant air dehumidification system," Applied Energy, Elsevier, vol. 228(C), pages 12-20.
    12. Mei, L. & Dai, Y.J., 2008. "A technical review on use of liquid-desiccant dehumidification for air-conditioning application," Renewable and Sustainable Energy Reviews, Elsevier, vol. 12(3), pages 662-689, April.
    13. Luo, Yimo & Yang, Hongxing & Lu, Lin, 2014. "Dynamic and microscopic simulation of the counter-current flow in a liquid desiccant dehumidifier," Applied Energy, Elsevier, vol. 136(C), pages 1018-1025.
    14. Keniar, Khoudor & Ghali, Kamel & Ghaddar, Nesreen, 2015. "Study of solar regenerated membrane desiccant system to control humidity and decrease energy consumption in office spaces," Applied Energy, Elsevier, vol. 138(C), pages 121-132.
    15. Shih-Cheng Hu & Angus Shiue & Yi-Shiung Chiu & Archy Wang & Jacky Chen, 2016. "Simplified Heat and Mass Transfer Model for Cross-Flow and Countercurrent Flow Packed Bed Tower Dehumidifiers with a Liquid Desiccant System," Sustainability, MDPI, vol. 8(12), pages 1-13, December.
    16. Peng, Donggen & Zhang, Xiaosong, 2016. "Experimental investigation on regeneration performance, heat and mass transfer characteristics in a forced solar collector/regenerator," Energy, Elsevier, vol. 101(C), pages 296-308.
    17. Yon, Hao Ren & Cai, Wenjian & Wang, Youyi & Shen, Suping, 2018. "Performance investigation on a novel liquid desiccant regeneration system operating in vacuum condition," Applied Energy, Elsevier, vol. 211(C), pages 249-258.
    18. Zhang, Tao & Liu, Xiaohua & Jiang, Yi, 2014. "Development of temperature and humidity independent control (THIC) air-conditioning systems in China—A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 29(C), pages 793-803.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Su, Wei & Lu, Zhifei & She, Xiaohui & Zhou, Junming & Wang, Feng & Sun, Bo & Zhang, Xiaosong, 2022. "Liquid desiccant regeneration for advanced air conditioning: A comprehensive review on desiccant materials, regenerators, systems and improvement technologies," Applied Energy, Elsevier, vol. 308(C).
    2. Zhou, Dengji & Jia, Xingyun & Ma, Shixi & Shao, Tiemin & Huang, Dawen & Hao, Jiarui & Li, Taotao, 2022. "Dynamic simulation of natural gas pipeline network based on interpretable machine learning model," Energy, Elsevier, vol. 253(C).

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Zhang, Ning & Yin, Shao-You & Li, Min, 2018. "Model-based optimization for a heat pump driven and hollow fiber membrane hybrid two-stage liquid desiccant air dehumidification system," Applied Energy, Elsevier, vol. 228(C), pages 12-20.
    2. Wu, Qiong & Cai, WenJian & Shen, Suping & Wang, Xinli & Ren, Haoren, 2017. "A regulation strategy of working concentration in the dehumidifier of liquid desiccant air conditioner," Applied Energy, Elsevier, vol. 202(C), pages 648-661.
    3. Su, Wei & Lu, Zhifei & She, Xiaohui & Zhou, Junming & Wang, Feng & Sun, Bo & Zhang, Xiaosong, 2022. "Liquid desiccant regeneration for advanced air conditioning: A comprehensive review on desiccant materials, regenerators, systems and improvement technologies," Applied Energy, Elsevier, vol. 308(C).
    4. Islam, M.R. & Alan, S.W.L. & Chua, K.J., 2018. "Studying the heat and mass transfer process of liquid desiccant for dehumidification and cooling," Applied Energy, Elsevier, vol. 221(C), pages 334-347.
    5. Juan Prieto & Antonio Atienza-Márquez & Alberto Coronas, 2021. "Modeling and Dynamic Simulation of a Hybrid Liquid Desiccant System with Non-Adiabatic Falling-Film Air-Solution Contactors for Air Conditioning Applications in Buildings," Energies, MDPI, vol. 14(2), pages 1-20, January.
    6. Wen, Tao & Lu, Lin, 2019. "A review of correlations and enhancement approaches for heat and mass transfer in liquid desiccant dehumidification system," Applied Energy, Elsevier, vol. 239(C), pages 757-784.
    7. Gao, D.C. & Sun, Y.J. & Ma, Z. & Ren, H., 2021. "A review on integration and design of desiccant air-conditioning systems for overall performance improvements," Renewable and Sustainable Energy Reviews, Elsevier, vol. 141(C).
    8. Liang, Chenjiyu & Li, Xianting & Zheng, Gonghang, 2022. "Optimizing air conditioning systems by considering the grades of sensible and latent heat loads," Applied Energy, Elsevier, vol. 322(C).
    9. Thu, K. & Mitra, S. & Saha, B.B. & Srinivasa Murthy, S., 2018. "Thermodynamic feasibility evaluation of hybrid dehumidification – mechanical vapour compression systems," Applied Energy, Elsevier, vol. 213(C), pages 31-44.
    10. Gurubalan, A. & Maiya, M.P. & Geoghegan, Patrick J., 2019. "A comprehensive review of liquid desiccant air conditioning system," Applied Energy, Elsevier, vol. 254(C).
    11. Giampieri, Alessandro & Ma, Zhiwei & Ling-Chin, Janie & Bao, Huashan & Smallbone, Andrew J. & Roskilly, Anthony Paul, 2022. "Liquid desiccant dehumidification and regeneration process: Advancing correlations for moisture and enthalpy effectiveness," Applied Energy, Elsevier, vol. 314(C).
    12. Jiang, Yuliang & Wang, Xinli & Zhao, Hongxia & Wang, Lei & Yin, Xiaohong & Jia, Lei, 2020. "Dynamic modeling and economic model predictive control of a liquid desiccant air conditioning," Applied Energy, Elsevier, vol. 259(C).
    13. Su, Bosheng & Han, Wei & Sui, Jun & Jin, Hongguang, 2017. "A two-stage liquid desiccant dehumidification system by the cascade utilization of low-temperature heat for industrial applications," Applied Energy, Elsevier, vol. 207(C), pages 643-653.
    14. Guo, Yi & Al-Jubainawi, Ali & Peng, Xueyuan, 2019. "Modelling and the feasibility study of a hybrid electrodialysis and thermal regeneration method for LiCl liquid desiccant dehumidification," Applied Energy, Elsevier, vol. 239(C), pages 1014-1036.
    15. Sebastian Englart & Krzysztof Rajski, 2021. "Performance Investigation of a Hollow Fiber Membrane-Based Desiccant Liquid Air Dehumidification System," Energies, MDPI, vol. 14(11), pages 1-20, June.
    16. Shukla, D.L. & Modi, K.V., 2022. "Influence of distinct input parameters on performance indices of dehumidifier, regenerator and on liquid desiccant-operated evaporative cooling system – A critical review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 168(C).
    17. Cui, Xin & Yan, Weichao & Liu, Yilin & Zhao, Min & Jin, Liwen, 2020. "Performance analysis of a hollow fiber membrane-based heat and mass exchanger for evaporative cooling," Applied Energy, Elsevier, vol. 271(C).
    18. Giampieri, A. & Roy, S. & Shivaprasad, K.V. & Smallbone, A.J. & Roskilly, A.P., 2022. "An integrated smart thermo-chemical energy network," Renewable and Sustainable Energy Reviews, Elsevier, vol. 168(C).
    19. Zhang, Lun & Song, Xia & Zhang, Xiaosong, 2019. "Theoretical analysis of exergy destruction and exergy flow in direct contact process between humid air and water/liquid desiccant solution," Energy, Elsevier, vol. 187(C).
    20. Ou, Xianhua & Cai, Wenjian & He, Xiongxiong & Zhai, Deqing, 2018. "Experimental investigations on heat and mass transfer performances of a liquid desiccant cooling and dehumidification system," Applied Energy, Elsevier, vol. 220(C), pages 164-175.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:240:y:2019:i:c:p:744-753. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.