IDEAS home Printed from https://ideas.repec.org/a/spr/masfgc/v27y2022i8d10.1007_s11027-022-10036-3.html
   My bibliography  Save this article

Comparative investigation of low GWP pure fluids as potential refrigerant options for a cascade system in seafood application

Author

Listed:
  • Santosh Kumar Saini

    (BITS Pilani)

  • Mani Sankar Dasgupta

    (BITS Pilani)

  • Kristina Norne Widell

    (SINTEF Ocean)

  • Souvik Bhattacharyya

    (BITS Pilani)

Abstract

The world is conscious about contribution to global warming from refrigeration and air-conditioning sector. A search is ongoing for energy-efficient refrigeration systems and environment-friendly refrigerants. Cascade refrigeration system (CRS) has been recognized as a prospective technology to improve energy efficiency while meeting multi-target temperatures. This study investigates various environment-friendly refrigerants for seafood processing and storage application having multi-target temperature in a warm climate. Fourteen potential low GWP pure fluids and one popularly used blend are identified as refrigerants based on literature survey. Out of these, six refrigerants (R41, R170, R1270, R404A, CO2, and N2O) were earmarked for the low-temperature circuit and ten (R152a, R161, RE170, R290, R1270, R1225ye(Z), R1234yf, R1234ze(E), R1243zf, and NH3) for the high-temperature circuit of the CRS. Suitable modelling and simulation techniques were employed to investigate the performance parameters namely COP, annual energy consumption, total equivalent warming impact, compressor volumetric displacement, compressor discharge temperature, and compression ratio. The refrigerant pair RE170-R1270 showed the best overall COP and also the lowest total equivalent CO2 emission for the application. NH3-CO2, the most studied refrigerant pair in literature, showed marginally lower COP; however, it has the lowest compressor volumetric displacement leading to a compact system with the minimum refrigerant charge. NH3 exhibited a higher compressor discharge temperature in all CRS, which can provide an opportunity for heat recovery. The study is expected to help the policy makers to frame regulations to encourage the use of sustainable refrigerants in the near future.

Suggested Citation

  • Santosh Kumar Saini & Mani Sankar Dasgupta & Kristina Norne Widell & Souvik Bhattacharyya, 2022. "Comparative investigation of low GWP pure fluids as potential refrigerant options for a cascade system in seafood application," Mitigation and Adaptation Strategies for Global Change, Springer, vol. 27(8), pages 1-27, December.
  • Handle: RePEc:spr:masfgc:v:27:y:2022:i:8:d:10.1007_s11027-022-10036-3
    DOI: 10.1007/s11027-022-10036-3
    as

    Download full text from publisher

    File URL: http://link.springer.com/10.1007/s11027-022-10036-3
    File Function: Abstract
    Download Restriction: Access to the full text of the articles in this series is restricted.

    File URL: https://libkey.io/10.1007/s11027-022-10036-3?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Purohit, Nilesh & Sharma, Vishaldeep & Sawalha, Samer & Fricke, Brian & Llopis, Rodrigo & Dasgupta, Mani Sankar, 2018. "Integrated supermarket refrigeration for very high ambient temperature," Energy, Elsevier, vol. 165(PA), pages 572-590.
    2. Sun, Zhili & Wang, Qifan & Xie, Zhiyuan & Liu, Shengchun & Su, Dandan & Cui, Qi, 2019. "Energy and exergy analysis of low GWP refrigerants in cascade refrigeration system," Energy, Elsevier, vol. 170(C), pages 1170-1180.
    3. Megdouli, K. & Ejemni, N. & Nahdi, E. & Mhimid, A. & Kairouani, L., 2017. "Thermodynamic analysis of a novel ejector expansion transcritical CO2/N2O cascade refrigeration (NEETCR) system for cooling applications at low temperatures," Energy, Elsevier, vol. 128(C), pages 586-600.
    4. Mark O. McLinden & J. Steven Brown & Riccardo Brignoli & Andrei F. Kazakov & Piotr A. Domanski, 2017. "Limited options for low-global-warming-potential refrigerants," Nature Communications, Nature, vol. 8(1), pages 1-9, April.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Qin, Yanbin & Li, Nanxi & Zhang, Hua & Jin, Binhui & Liu, Baolin, 2022. "Experimental characterization of an innovative refrigeration system coupled with Linde-Hampson cycle and auto-cascade cycle for multi-stage refrigeration temperature applications," Energy, Elsevier, vol. 240(C).
    2. Muhsin Kılıç, 2022. "Evaluation of Combined Thermal–Mechanical Compression Systems: A Review for Energy Efficient Sustainable Cooling," Sustainability, MDPI, vol. 14(21), pages 1-38, October.
    3. Liu, Hua & Zhao, Baiyang & Zhang, Zhiping & Li, Hongbo & Hu, Bin & Wang, R.Z., 2020. "Experimental validation of an advanced heat pump system with high-efficiency centrifugal compressor," Energy, Elsevier, vol. 213(C).
    4. Artur Bieniek & Jan Kuchmacz & Karol Sztekler & Lukasz Mika & Ewelina Radomska, 2021. "A New Method of Regulating the Cooling Capacity of a Cooling System with CO 2," Energies, MDPI, vol. 14(7), pages 1-18, March.
    5. He, Yijian & Jiang, Yunyun & Fan, Yuchen & Chen, Guangming & Tang, Liming, 2020. "Utilization of ultra-low temperature heat by a novel cascade refrigeration system with environmentally-friendly refrigerants," Renewable Energy, Elsevier, vol. 157(C), pages 204-213.
    6. Min-Ju Jeon, 2022. "Experimental Analysis of the R744/R404A Cascade Refrigeration System with Internal Heat Exchanger. Part 2: Exergy Characteristics," Energies, MDPI, vol. 15(3), pages 1-20, February.
    7. Huang, Tao & Bacher, Peder & Møller, Jan Kloppenborg & D’Ettorre, Francesco & Markussen, Wiebke Brix, 2023. "A step towards digital operations—A novel grey-box approach for modelling the heat dynamics of ultra-low temperature freezing chambers," Applied Energy, Elsevier, vol. 349(C).
    8. Sovacool, Benjamin K. & Griffiths, Steve & Kim, Jinsoo & Bazilian, Morgan, 2021. "Climate change and industrial F-gases: A critical and systematic review of developments, sociotechnical systems and policy options for reducing synthetic greenhouse gas emissions," Renewable and Sustainable Energy Reviews, Elsevier, vol. 141(C).
    9. Laura Nebot-Andrés & Daniel Calleja-Anta & Daniel Sánchez & Ramón Cabello & Rodrigo Llopis, 2019. "Thermodynamic Analysis of a CO 2 Refrigeration Cycle with Integrated Mechanical Subcooling," Energies, MDPI, vol. 13(1), pages 1-17, December.
    10. Yang, Fufang & Yang, Fubin & Liu, Qiang & Chu, Qingfu & Yang, Zhen & Duan, Yuanyuan, 2022. "Thermodynamic analysis of working fluids: What is the highest performance of the sub- and trans-critical organic Rankine cycles?," Energy, Elsevier, vol. 241(C).
    11. Albà, C.G. & Alkhatib, I.I.I. & Llovell, F. & Vega, L.F., 2023. "Hunting sustainable refrigerants fulfilling technical, environmental, safety and economic requirements," Renewable and Sustainable Energy Reviews, Elsevier, vol. 188(C).
    12. Wang, Bo & Chao, Yijun & Zhao, Qinyu & Wang, Haoren & Wang, Yabin & Gan, Zhihua, 2021. "A high efficiency stirling-type pulse tube refrigerator for cooling above 200 K," Energy, Elsevier, vol. 215(PB).
    13. Wang, Ziyu & Lu, Zhenyu & Yelishala, Sai C. & Metghalchi, Hameed & Levendis, Yiannis A., 2021. "Flame characteristics of propane-air-carbon dioxide blends at elevated temperatures and pressures," Energy, Elsevier, vol. 228(C).
    14. Selim Karkour & Tomohiko Ihara & Tadahiro Kuwayama & Kazuki Yamaguchi & Norihiro Itsubo, 2021. "Life Cycle Assessment of Residential Air Conditioners Considering the Benefits of Their Use: A Case Study in Indonesia," Energies, MDPI, vol. 14(2), pages 1-18, January.
    15. Mingzhang Pan & Huan Zhao & Dongwu Liang & Yan Zhu & Youcai Liang & Guangrui Bao, 2020. "A Review of the Cascade Refrigeration System," Energies, MDPI, vol. 13(9), pages 1-26, May.
    16. Qin, Yanbin & Li, Nanxi & Zhang, Hua & Liu, Baolin, 2021. "Energy and exergy analysis of a Linde-Hampson refrigeration system using R170, R41 and R1132a as low-GWP refrigerant blend components to replace R23," Energy, Elsevier, vol. 229(C).
    17. Besagni, Giorgio, 2019. "Ejectors on the cutting edge: The past, the present and the perspective," Energy, Elsevier, vol. 170(C), pages 998-1003.
    18. Xu, Weicong & Zhao, Ruikai & Deng, Shuai & Zhao, Li & Mao, Samuel S., 2021. "Is zeotropic working fluid a promising option for organic Rankine cycle: A quantitative evaluation based on literature data," Renewable and Sustainable Energy Reviews, Elsevier, vol. 148(C).
    19. Li, Hao & Gong, Xiufeng & Xu, Wenjie & Li, Minxia & Dang, Chaobin, 2020. "Effects of climate on the solar-powered R1234ze/CO2 cascade cycle for space cooling," Renewable Energy, Elsevier, vol. 153(C), pages 870-883.
    20. J. Catalán-Gil & L. Nebot-Andrés & D. Sánchez & R. Llopis & R. Cabello & D. Calleja-Anta, 2020. "Improvements in CO 2 Booster Architectures with Different Economizer Arrangements," Energies, MDPI, vol. 13(5), pages 1-29, March.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:spr:masfgc:v:27:y:2022:i:8:d:10.1007_s11027-022-10036-3. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.springer.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.