Author
Listed:
- Kangning Xiong
(State Key Laboratory of Green Building, School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China)
- Yang Liu
(State Key Laboratory of Green Building, School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China)
- Zhuoyu Li
(State Key Laboratory of Green Building, School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China)
- Qingsong Pan
(State Key Laboratory of Green Building, School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China)
Abstract
Chip-level cooling has become a thermal bottleneck in next-generation data centers. Although previous studies have optimized evaporator wick structures, they are limited to a single condensation path and ignore the combined effects of the loop heat pipe (LHP) orientation on the capillary wick (CW) replenishment and reflux subcooling. To bridge this gap, this study successfully designed an innovative flat-plate evaporator water-cooled LHP with a parallel condensation pipeline. Experiments were conducted with a 20 °C coolant and at a 4 L/min flow rate across nine orientations. The heat transfer characteristics of LHPs with parallel and series condensation pipelines were compared. The analysis focused on the relationship between the working fluid (WF) replenishment of the CW and the WF reflux temperature in the compensating chamber (CC). The experimental results demonstrated that the parallel condensation LHP could sustainably dissipate 750 W without thermal runaway. At this power, the minimum junction temperature of 82.34 °C was measured at orientation 2 (+60°). For low power and at the nine orientations, the series LHP generally had lower temperatures. However, when the power exceeded 600 W, the parallel LHP showed lower temperatures at orientations 1 (+90°), 2 (+60°), and 3 (+30°). At orientation 9, the parallel LHP had lower temperatures when the power surpassed 200 W. Theoretical analysis indicated that the orientation changes affected the heat transfer via the WF reflux temperature, reflux resistance, and CW replenishment rate. Furthermore, the LHP system we developed in this study is capable of fully satisfying the cooling requirements of data center server chips.
Suggested Citation
Kangning Xiong & Yang Liu & Zhuoyu Li & Qingsong Pan, 2025.
"Comparison Study of Novel Flat Evaporator Loop Heat Pipes with Different Types of Condensation Pipeline,"
Energies, MDPI, vol. 18(16), pages 1-27, August.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:16:p:4247-:d:1721284
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:16:p:4247-:d:1721284. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.