IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2023i7p2990-d1106877.html
   My bibliography  Save this article

A New Method for Determining Outdoor Humidity Ratio of Natatorium in Transition Season

Author

Listed:
  • Jiaxiang Lei

    (School of Information and Control Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China)

  • Honglian Li

    (School of Information and Control Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
    State Key Laboratory of Green Building in Western China, Xi’an University of Architecture and Technology, Xi’an 710055, China)

  • Chengwang Li

    (School of Information and Control Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China)

  • Minrui Xu

    (School of Environment, Education and Development, The University of Manchester, Manchester M1 5GD, UK)

Abstract

The natatorium’s ventilation problem receives much concern because of its large wet load. The outdoor humidity ratio in transition season is the basic design parameter of the ventilation calculation, directly affecting the rationality of architectural design. At present, the ventilation-curve (V-C) method is the most widely used method to determine the outdoor humidity ratio in the transition season in China. However, due to failing to reflect non-guaranteed hours, the rationality of this value is difficult to assess by employing this approach. This paper presents a new method, the typical transition season method (TTS), for determining the outdoor humidity ratio in the transition season of a natatorium. The TTS method selects the transition season based on the typical meteorological year (TMY) data and calculates the outdoor humidity ratio with multiple non-guaranteed hours. This can well-represent the local perennial climate characteristics and clearly reflect the non-guaranteed hours. In this study, through selecting six typical representative cities in China, the evaluation of the outdoor humidity ratio is achieved through calculating ventilation volume and air change rate, verifying the rationality of this method. The results show that the humidity ratio obtained by the V-C method is lower than that obtained by the TTS method at about 2 g/kg without guarantee of 200 h humidity ratio, and even that the maximum difference is 6.64 g/kg. Meanwhile, the validation results of the ventilation calculation show that the humidity ratio determined by the V-C method cannot meet the minimum design requirements in five cities, while the humidity ratio obtained by the TTS method cannot meet the requirements in only one city.

Suggested Citation

  • Jiaxiang Lei & Honglian Li & Chengwang Li & Minrui Xu, 2023. "A New Method for Determining Outdoor Humidity Ratio of Natatorium in Transition Season," Energies, MDPI, vol. 16(7), pages 1-17, March.
  • Handle: RePEc:gam:jeners:v:16:y:2023:i:7:p:2990-:d:1106877
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/7/2990/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/7/2990/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Li, Honglian & Huang, Jin & Hu, Yao & Wang, Shangyu & Liu, Jing & Yang, Liu, 2021. "A new TMY generation method based on the entropy-based TOPSIS theory for different climatic zones in China," Energy, Elsevier, vol. 231(C).
    2. Li, Honglian & Yang, Yi & Lv, Kailin & Liu, Jing & Yang, Liu, 2020. "Compare several methods of select typical meteorological year for building energy simulation in China," Energy, Elsevier, vol. 209(C).
    3. Piotr Ciuman & Jan Kaczmarczyk, 2021. "Numerical Analysis of the Energy Consumption of Ventilation Processes in the School Swimming Pool," Energies, MDPI, vol. 14(4), pages 1-18, February.
    4. Sun, Jingting & Li, Zhengrong & Xiao, Fu & Xiao, Jianzhuang, 2020. "Generation of typical meteorological year for integrated climate based daylight modeling and building energy simulation," Renewable Energy, Elsevier, vol. 160(C), pages 721-729.
    5. Jani, D.B. & Mishra, Manish & Sahoo, P.K., 2016. "Solid desiccant air conditioning – A state of the art review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 60(C), pages 1451-1469.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Jahns, Christopher & Osinski, Paul & Weber, Christoph, 2023. "A statistical approach to modeling the variability between years in renewable infeed on energy system level," Energy, Elsevier, vol. 263(PA).
    2. Jani, D.B. & Mishra, Manish & Sahoo, P.K., 2017. "Application of artificial neural network for predicting performance of solid desiccant cooling systems – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 80(C), pages 352-366.
    3. Speerforck, Arne & Schmitz, Gerhard, 2016. "Experimental investigation of a ground-coupled desiccant assisted air conditioning system," Applied Energy, Elsevier, vol. 181(C), pages 575-585.
    4. Hwang, Won-Baek & Choi, Sun & Lee, Dae-Young, 2017. "In-depth analysis of the performance of hybrid desiccant cooling system incorporated with an electric heat pump," Energy, Elsevier, vol. 118(C), pages 324-332.
    5. Fekadu, Geleta & Subudhi, Sudhakar, 2018. "Renewable energy for liquid desiccants air conditioning system: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 93(C), pages 364-379.
    6. Li, Honglian & Huang, Jin & Hu, Yao & Wang, Shangyu & Liu, Jing & Yang, Liu, 2021. "A new TMY generation method based on the entropy-based TOPSIS theory for different climatic zones in China," Energy, Elsevier, vol. 231(C).
    7. Shamim, Jubair A. & Hsu, Wei-Lun & Paul, Soumyadeep & Yu, Lili & Daiguji, Hirofumi, 2021. "A review of solid desiccant dehumidifiers: Current status and near-term development goals in the context of net zero energy buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 137(C).
    8. Gado, Mohamed G. & Ookawara, Shinichi & Nada, Sameh & El-Sharkawy, Ibrahim I., 2021. "Hybrid sorption-vapor compression cooling systems: A comprehensive overview," Renewable and Sustainable Energy Reviews, Elsevier, vol. 143(C).
    9. Yuan, Jihui & Huang, Pei & Chai, Jiale, 2022. "Development of a calibrated typical meteorological year weather file in system design of zero-energy building for performance improvements," Energy, Elsevier, vol. 259(C).
    10. Venegas, Tomas & Qu, Ming & Nawaz, Kashif & Wang, Lingshi, 2021. "Critical review and future prospects for desiccant coated heat exchangers: Materials, design, and manufacturing," Renewable and Sustainable Energy Reviews, Elsevier, vol. 151(C).
    11. Katarzyna Ratajczak & Edward Szczechowiak & Aneta Pobudkowska, 2023. "Energy-Saving Scenarios of an Existing Swimming Pool with the Use of Simple In Situ Measurement," Energies, MDPI, vol. 16(16), pages 1-25, August.
    12. Feng, Meiqing & Chen, Yaning & Duan, Weili & Fang, Gonghuan & li, Zhi & Jiao, Li & Sun, Fan & Li, Yupeng & Hou, Yifeng, 2022. "Comprehensive evaluation of the water-energy-food nexus in the agricultural management of the Tarim River Basin, Northwest China," Agricultural Water Management, Elsevier, vol. 271(C).
    13. Wu, X.N. & Ge, T.S. & Dai, Y.J. & Wang, R.Z., 2019. "Investigation on novel desiccant wheel using wood pulp fiber paper with high coating ratio as matrix," Energy, Elsevier, vol. 176(C), pages 493-504.
    14. Niemann, Peter & Schmitz, Gerhard, 2020. "Air conditioning system with enthalpy recovery for space heating and air humidification: An experimental and numerical investigation," Energy, Elsevier, vol. 213(C).
    15. Wu, X.N. & Ge, T.S. & Dai, Y.J. & Wang, R.Z., 2018. "Review on substrate of solid desiccant dehumidification system," Renewable and Sustainable Energy Reviews, Elsevier, vol. 82(P3), pages 3236-3249.
    16. Li, Honglian & Zhang, Tiantian & Wang, An & Wang, Mengli & Huang, Jin & Hu, Yao, 2023. "A new method of generating extreme building energy year and its application," Energy, Elsevier, vol. 278(PB).
    17. Serena Summa & Giada Remia & Ambra Sebastianelli & Gianluca Coccia & Costanzo Di Perna, 2022. "Impact on Thermal Energy Needs Caused by the Use of Different Solar Irradiance Decomposition and Transposition Models: Application of EN ISO 52016-1 and EN ISO 52010-1 Standards for Five European Citi," Energies, MDPI, vol. 15(23), pages 1-18, November.
    18. Geraldi, Matheus Soares & Ghisi, Enedir, 2022. "Data-driven framework towards realistic bottom-up energy benchmarking using an Artificial Neural Network," Applied Energy, Elsevier, vol. 306(PA).
    19. Elnour, Mariam & Fadli, Fodil & Himeur, Yassine & Petri, Ioan & Rezgui, Yacine & Meskin, Nader & Ahmad, Ahmad M., 2022. "Performance and energy optimization of building automation and management systems: Towards smart sustainable carbon-neutral sports facilities," Renewable and Sustainable Energy Reviews, Elsevier, vol. 162(C).
    20. Shuai, Jing & Zhao, Yujia & Wang, Yilan & Cheng, Jinhua, 2022. "Renewable energy product competitiveness: Evidence from the United States, China and India," Energy, Elsevier, vol. 249(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:7:p:2990-:d:1106877. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.