IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v173y2021icp913-925.html
   My bibliography  Save this article

A semi-experimental method for evaluating frosting performance of air source heat pumps

Author

Listed:
  • Pu, Jihong
  • Shen, Chao
  • Zhang, Chunxiao
  • Liu, Xingjiang

Abstract

Frosting has always been a crucial problem for air source heat pumps (ASHPs) operated in heating mode. Quantitative evaluation of frosting is of vital importance to the development of technologies against frosting. Although frosting maps have been developed in many studies, they are specific for unique systems. To evaluate the frosting performance of arbitrary system, a semi-experimental method, to depict frosting evaluation plot, was proposed in the present study. In the frosting evaluation plot, frosting region was clarified, and the frosting driving forces with the effect air temperature and relative humidity (RH) were evaluated, through theoretical calculation of Gibbs free energy change. After that, experiments were conducted to verify the frosting evaluation plot, and the results demonstrated the present method was feasible. In some experimental cases, the inlet segment of the heat exchanger escaped from frosting but the outlet segment frosted. As implementation of the semi-experimental method, the methodology was utilized to clarify the air temperature and RH ranges causing uneven frosting. In addition, the frosting evaluation plot with impact of air velocity was drawn. The results suggested that, increased air velocity restrained frosting, and reduced the chance of uneven frosting.

Suggested Citation

  • Pu, Jihong & Shen, Chao & Zhang, Chunxiao & Liu, Xingjiang, 2021. "A semi-experimental method for evaluating frosting performance of air source heat pumps," Renewable Energy, Elsevier, vol. 173(C), pages 913-925.
  • Handle: RePEc:eee:renene:v:173:y:2021:i:c:p:913-925
    DOI: 10.1016/j.renene.2021.04.029
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148121005413
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2021.04.029?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Lohani, S.P. & Schmidt, D., 2010. "Comparison of energy and exergy analysis of fossil plant, ground and air source heat pump building heating system," Renewable Energy, Elsevier, vol. 35(6), pages 1275-1282.
    2. Li, Gang, 2015. "Comprehensive investigations of life cycle climate performance of packaged air source heat pumps for residential application," Renewable and Sustainable Energy Reviews, Elsevier, vol. 43(C), pages 702-710.
    3. Song, Mengjie & Deng, Shiming & Dang, Chaobin & Mao, Ning & Wang, Zhihua, 2018. "Review on improvement for air source heat pump units during frosting and defrosting," Applied Energy, Elsevier, vol. 211(C), pages 1150-1170.
    4. Tarnawski, V.R. & Leong, W.H. & Momose, T. & Hamada, Y., 2009. "Analysis of ground source heat pumps with horizontal ground heat exchangers for northern Japan," Renewable Energy, Elsevier, vol. 34(1), pages 127-134.
    5. Song, Mengjie & Xia, Liang & Mao, Ning & Deng, Shiming, 2016. "An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil," Applied Energy, Elsevier, vol. 164(C), pages 36-44.
    6. Wang, W. & Feng, Y.C. & Zhu, J.H. & Li, L.T. & Guo, Q.C. & Lu, W.P., 2013. "Performances of air source heat pump system for a kind of mal-defrost phenomenon appearing in moderate climate conditions," Applied Energy, Elsevier, vol. 112(C), pages 1138-1145.
    7. Zhou, Chaohui & Ni, Long & Li, Jun & Lin, Zeri & Wang, Jun & Fu, Xuhui & Yao, Yang, 2019. "Air-source heat pump heating system with a new temperature and hydraulic-balance control strategy: A field experiment in a teaching building," Renewable Energy, Elsevier, vol. 141(C), pages 148-161.
    8. Ni, Long & Dong, Jiankai & Yao, Yang & Shen, Chao & Qv, Dehu & Zhang, Xuedan, 2015. "A review of heat pump systems for heating and cooling of buildings in China in the last decade," Renewable Energy, Elsevier, vol. 84(C), pages 30-45.
    9. Xiao, Biao & He, Lin & Zhang, Shihang & Kong, Tingting & Hu, Bin & Wang, R.Z., 2020. "Comparison and analysis on air-to-air and air-to-water heat pump heating systems," Renewable Energy, Elsevier, vol. 146(C), pages 1888-1896.
    10. Wang, Xinru & Xia, Liang & Bales, Chris & Zhang, Xingxing & Copertaro, Benedetta & Pan, Song & Wu, Jinshun, 2020. "A systematic review of recent air source heat pump (ASHP) systems assisted by solar thermal, photovoltaic and photovoltaic/thermal sources," Renewable Energy, Elsevier, vol. 146(C), pages 2472-2487.
    11. Huang, Dong & Li, Quanxu & Yuan, Xiuling, 2009. "Comparison between hot-gas bypass defrosting and reverse-cycle defrosting methods on an air-to-water heat pump," Applied Energy, Elsevier, vol. 86(9), pages 1697-1703, September.
    12. Song, Mengjie & Deng, Shiming & Mao, Ning & Ye, Xianming, 2016. "An experimental study on defrosting performance for an air source heat pump unit with a horizontally installed multi-circuit outdoor coil," Applied Energy, Elsevier, vol. 165(C), pages 371-382.
    13. Wang, Feng & Liang, Caihua & Zhang, Xiaosong, 2018. "Research of anti-frosting technology in refrigeration and air conditioning fields: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 81(P1), pages 707-722.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Tomas Kropas & Giedrė Streckienė & Juozas Bielskus, 2021. "Experimental Investigation of Frost Formation Influence on an Air Source Heat Pump Evaporator," Energies, MDPI, vol. 14(18), pages 1-15, September.
    2. Wang, Haidan & Song, Yulong & Qiao, Yiyou & Li, Shengbo & Cao, Feng, 2022. "Rational assessment and selection of air source heat pump system operating with CO2 and R407C for electric bus," Renewable Energy, Elsevier, vol. 182(C), pages 86-101.
    3. Li, Yunhai & Li, Zhaomeng & Fan, Yi & Zeng, Cheng & Cui, Yu & Zhao, Xudong & Li, Jing & Chen, Ying & Chen, Jianyong & Shen, Chao, 2023. "Experimental investigation of a novel two-stage heat recovery heat pump system employing the vapor injection compressor at cold ambience and high water temperature conditions," Renewable Energy, Elsevier, vol. 205(C), pages 678-694.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Tomas Kropas & Giedrė Streckienė & Juozas Bielskus, 2021. "Experimental Investigation of Frost Formation Influence on an Air Source Heat Pump Evaporator," Energies, MDPI, vol. 14(18), pages 1-15, September.
    2. Yang, Bowen & Dong, Jiankai & Zhang, Long & Song, Mengjie & Jiang, Yiqiang & Deng, Shiming, 2019. "Heating and energy storage characteristics of multi-split air source heat pump based on energy storage defrosting," Applied Energy, Elsevier, vol. 238(C), pages 303-310.
    3. Wei, Wenzhe & Ni, Long & Li, Shuyi & Wang, Wei & Yao, Yang & Xu, Laifu & Yang, Yahua, 2020. "A new frosting map of variable-frequency air source heat pump in severe cold region considering the variation of heating load," Renewable Energy, Elsevier, vol. 161(C), pages 184-199.
    4. Wang, Wei & Zhang, Shiqiang & Li, Zhaoyang & Sun, Yuying & Deng, Shiming & Wu, Xu, 2020. "Determination of the optimal defrosting initiating time point for an ASHP unit based on the minimum loss coefficient in the nominal output heating energy," Energy, Elsevier, vol. 191(C).
    5. Song, Mengjie & Deng, Shiming & Dang, Chaobin & Mao, Ning & Wang, Zhihua, 2018. "Review on improvement for air source heat pump units during frosting and defrosting," Applied Energy, Elsevier, vol. 211(C), pages 1150-1170.
    6. Adnan Rasheed & Jong Won Lee & Hyeon Tae Kim & Hyun Woo Lee, 2022. "Study on Heating and Cooling Performance of Air-to-Water Heat Pump System for Protected Horticulture," Energies, MDPI, vol. 15(15), pages 1-19, July.
    7. Carroll, P. & Chesser, M. & Lyons, P., 2020. "Air Source Heat Pumps field studies: A systematic literature review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 134(C).
    8. Song, Mengjie & Xia, Liang & Mao, Ning & Deng, Shiming, 2016. "An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil," Applied Energy, Elsevier, vol. 164(C), pages 36-44.
    9. Song, Mengjie & Gong, Guangcai & Mao, Ning & Deng, Shiming & Wang, Zhihua, 2017. "Experimental investigation on an air source heat pump unit with a three-circuit outdoor coil for its reverse cycle defrosting termination temperature," Applied Energy, Elsevier, vol. 204(C), pages 1388-1398.
    10. Zhang, Qunli & Zhang, Lin & Nie, Jinzhe & Li, Yinlong, 2017. "Techno-economic analysis of air source heat pump applied for space heating in northern China," Applied Energy, Elsevier, vol. 207(C), pages 533-542.
    11. Xiong, Yongqing & Yang, Xiaohan, 2016. "Government subsidies for the Chinese photovoltaic industry," Energy Policy, Elsevier, vol. 99(C), pages 111-119.
    12. Li, Sihui & Gong, Guangcai & Peng, Jinqing, 2019. "Dynamic coupling method between air-source heat pumps and buildings in China’s hot-summer/cold-winter zone," Applied Energy, Elsevier, vol. 254(C).
    13. Haolu Liu & Khurram Yousaf & Kunjie Chen & Rui Fan & Jiaxin Liu & Shakeel Ahmed Soomro, 2018. "Design and Thermal Analysis of an Air Source Heat Pump Dryer for Food Drying," Sustainability, MDPI, vol. 10(9), pages 1-17, September.
    14. Mao, Ning & Hao, Jingyu & Cui, Borui & Li, Yuxing & Song, Mengjie & Xu, Yingjie & Deng, Shiming, 2018. "Energy performance of a bedroom task/ambient air conditioning (TAC) system applied in different climate zones of China," Energy, Elsevier, vol. 159(C), pages 724-736.
    15. Haihui Tan & Xiaofeng Zhang & Li Zhang & Tangfei Tao & Guanghua Xu, 2019. "Ultrasonic Guided Wave Phased Array Focusing Technology and Its Application to Defrosting Performance Improvement of Air-Source Heat Pumps," Energies, MDPI, vol. 12(16), pages 1-18, August.
    16. Yi Zhang & Guanmin Zhang & Aiqun Zhang & Yinhan Jin & Ruirui Ru & Maocheng Tian, 2018. "Frosting Phenomenon and Frost-Free Technology of Outdoor Air Heat Exchanger for an Air-Source Heat Pump System in China: An Analysis and Review," Energies, MDPI, vol. 11(10), pages 1-36, October.
    17. Song, Mengjie & Xu, Xiangguo & Mao, Ning & Deng, Shiming & Xu, Yingjie, 2017. "Energy transfer procession in an air source heat pump unit during defrosting," Applied Energy, Elsevier, vol. 204(C), pages 679-689.
    18. Song, Mengjie & Xia, Liang & Deng, Shiming, 2016. "A modeling study on alleviating uneven defrosting for a vertical three-circuit outdoor coil in an air source heat pump unit during reverse cycle defrosting," Applied Energy, Elsevier, vol. 161(C), pages 268-278.
    19. Naili, Nabiha & Hazami, Majdi & Attar, Issam & Farhat, Abdelhamid, 2013. "In-field performance analysis of ground source cooling system with horizontal ground heat exchanger in Tunisia," Energy, Elsevier, vol. 61(C), pages 319-331.
    20. Hu, Wenju & Song, Mengjie & Jiang, Yiqiang & Yao, Yang & Gao, Yan, 2019. "A modeling study on the heat storage and release characteristics of a phase change material based double-spiral coiled heat exchanger in an air source heat pump for defrosting," Applied Energy, Elsevier, vol. 236(C), pages 877-892.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:173:y:2021:i:c:p:913-925. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.