IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v74y2014icp555-566.html
   My bibliography  Save this article

Linear algebra solution to psychometric analysis of air-conditioning systems

Author

Listed:
  • Ghiaus, Christian

Abstract

The typical air conditioning steady-state processes are graphically represented by straight or curve lines on the psychrometric chart. Neglecting the sensible heat of the moisture results in decoupling the sensible and the latent heat, that results in linear variation of the enthalpy on the psychrometric chart. The vapor saturation curve may also be linearized by using Newton's method. If the mass flow rates of the dry air are known and if the computational causality is assigned to correspond to the physical causality (i.e. if a direct modeling problem is treated), then the steady-state models of the psychrometric processes become linear algebraic equations in the vector space defined by the dry bulb temperature and the humidity ratio. Coupling these models to describe a complex HVAC (heating ventilation air-conditioning) system results in a system of linear equations that solves a direct (or psychometric analysis) problem in which the inputs of the model are a subset of the set of independent variables of the psychical process, the outputs of the model are a subset of the set of the dependent variables of the physical process, and the unknowns are the psychometric states of the moist air. The algorithm that implements this method represents a computational alternative to graphical representations and manual solutions to psychometric analysis of air-conditioning systems.

Suggested Citation

  • Ghiaus, Christian, 2014. "Linear algebra solution to psychometric analysis of air-conditioning systems," Energy, Elsevier, vol. 74(C), pages 555-566.
  • Handle: RePEc:eee:energy:v:74:y:2014:i:c:p:555-566
    DOI: 10.1016/j.energy.2014.07.021
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544214008433
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2014.07.021?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Seem, J.E. & House, J.M., 2010. "Development and evaluation of optimization-based air economizer strategies," Applied Energy, Elsevier, vol. 87(3), pages 910-924, March.
    2. Kim, Min-Hwi & Jeong, Jae-Weon, 2013. "Cooling performance of a 100% outdoor air system integrated with indirect and direct evaporative coolers," Energy, Elsevier, vol. 52(C), pages 245-257.
    3. Farmahini-Farahani, Moien & Delfani, Shahram & Esmaeelian, Jafar, 2012. "Exergy analysis of evaporative cooling to select the optimum system in diverse climates," Energy, Elsevier, vol. 40(1), pages 250-257.
    4. Ghiaus, Christian, 2013. "Causality issue in the heat balance method for calculating the design heating and cooling load," Energy, Elsevier, vol. 50(C), pages 292-301.
    5. Lee, S.H. & Lee, W.L., 2013. "Site verification and modeling of desiccant-based system as an alternative to conventional air-conditioning systems for wet markets," Energy, Elsevier, vol. 55(C), pages 1076-1083.
    6. Bergero, Stefano & Chiari, Anna, 2011. "On the performances of a hybrid air-conditioning system in different climatic conditions," Energy, Elsevier, vol. 36(8), pages 5261-5273.
    7. Tu, Rang & Liu, Xiao-Hua & Jiang, Yi, 2014. "Performance analysis of a two-stage desiccant cooling system," Applied Energy, Elsevier, vol. 113(C), pages 1562-1574.
    8. Nóbrega, C.E.L. & Brum, N.C.L., 2011. "A graphical procedure for desiccant cooling cycle design," Energy, Elsevier, vol. 36(3), pages 1564-1570.
    9. Fumo, Nelson, 2014. "A review on the basics of building energy estimation," Renewable and Sustainable Energy Reviews, Elsevier, vol. 31(C), pages 53-60.
    10. Yang, C.M. & Chen, C.C. & Chen, S.L., 2013. "Energy-efficient air conditioning system with combination of radiant cooling and periodic total heat exchanger," Energy, Elsevier, vol. 59(C), pages 467-477.
    11. Panaras, G. & Mathioulakis, E. & Belessiotis, V., 2011. "Solid desiccant air-conditioning systems – Design parameters," Energy, Elsevier, vol. 36(5), pages 2399-2406.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Sorrentino, Marco & Acconcia, Matteo & Panagrosso, Davide & Trifirò, Alena, 2016. "Model-based energy monitoring and diagnosis of telecommunication cooling systems," Energy, Elsevier, vol. 116(P1), pages 761-772.
    2. Buonomano, Annamaria & Montanaro, Umberto & Palombo, Adolfo & Santini, Stefania, 2016. "Dynamic building energy performance analysis: A new adaptive control strategy for stringent thermohygrometric indoor air requirements," Applied Energy, Elsevier, vol. 163(C), pages 361-386.
    3. Naveros, I. & Ghiaus, C., 2015. "Order selection of thermal models by frequency analysis of measurements for building energy efficiency estimation," Applied Energy, Elsevier, vol. 139(C), pages 230-244.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Chen, Chih-Hao & Hsu, Chien-Yeh & Chen, Chih-Chieh & Chiang, Yuan-Ching & Chen, Sih-Li, 2016. "Silica gel/polymer composite desiccant wheel combined with heat pump for air-conditioning systems," Energy, Elsevier, vol. 94(C), pages 87-99.
    2. Angrisani, Giovanni & Roselli, Carlo & Sasso, Maurizio, 2015. "Experimental assessment of the energy performance of a hybrid desiccant cooling system and comparison with other air-conditioning technologies," Applied Energy, Elsevier, vol. 138(C), pages 533-545.
    3. Ruivo, Celestino R. & Goldsworthy, Mark & Intini, Manuel, 2014. "Interpolation methods to predict the influence of inlet airflow states on desiccant wheel performance at low regeneration temperature," Energy, Elsevier, vol. 68(C), pages 765-772.
    4. Wang, H.H. & Ge, T.S. & Zhang, X.L. & Zhao, Y., 2016. "Experimental investigation on solar powered self-cooled cooling system based on solid desiccant coated heat exchanger," Energy, Elsevier, vol. 96(C), pages 176-186.
    5. Zouaoui, Ahlem & Zili-Ghedira, Leila & Ben Nasrallah, Sassi, 2016. "Open solid desiccant cooling air systems: A review and comparative study," Renewable and Sustainable Energy Reviews, Elsevier, vol. 54(C), pages 889-917.
    6. Sphaier, L.A. & Nóbrega, C.E.L., 2012. "Parametric analysis of components effectiveness on desiccant cooling system performance," Energy, Elsevier, vol. 38(1), pages 157-166.
    7. Thu, K. & Mitra, S. & Saha, B.B. & Srinivasa Murthy, S., 2018. "Thermodynamic feasibility evaluation of hybrid dehumidification – mechanical vapour compression systems," Applied Energy, Elsevier, vol. 213(C), pages 31-44.
    8. Gado, Mohamed G. & Ookawara, Shinichi & Nada, Sameh & El-Sharkawy, Ibrahim I., 2021. "Hybrid sorption-vapor compression cooling systems: A comprehensive overview," Renewable and Sustainable Energy Reviews, Elsevier, vol. 143(C).
    9. Campaniço, Hugo & Hollmuller, Pierre & Soares, Pedro M.M., 2014. "Assessing energy savings in cooling demand of buildings using passive cooling systems based on ventilation," Applied Energy, Elsevier, vol. 134(C), pages 426-438.
    10. Chiang, Yuan-Ching & Chen, Chih-Hao & Chiang, Yi-Chin & Chen, Sih-Li, 2016. "Circulating inclined fluidized beds with application for desiccant dehumidification systems," Applied Energy, Elsevier, vol. 175(C), pages 199-211.
    11. Muhammad Aleem & Ghulam Hussain & Muhammad Sultan & Takahiko Miyazaki & Muhammad H. Mahmood & Muhammad I. Sabir & Abdul Nasir & Faizan Shabir & Zahid M. Khan, 2020. "Experimental Investigation of Desiccant Dehumidification Cooling System for Climatic Conditions of Multan (Pakistan)," Energies, MDPI, vol. 13(21), pages 1-23, October.
    12. Kojok, Farah & Fardoun, Farouk & Younes, Rafic & Outbib, Rachid, 2016. "Hybrid cooling systems: A review and an optimized selection scheme," Renewable and Sustainable Energy Reviews, Elsevier, vol. 65(C), pages 57-80.
    13. Ohlsson, K.E. Anders & Olofsson, Thomas, 2021. "Benchmarking the practice of validation and uncertainty analysis of building energy models," Renewable and Sustainable Energy Reviews, Elsevier, vol. 142(C).
    14. Shazia Noor & Hadeed Ashraf & Muhammad Sultan & Zahid Mahmood Khan, 2020. "Evaporative Cooling Options for Building Air-Conditioning: A Comprehensive Study for Climatic Conditions of Multan (Pakistan)," Energies, MDPI, vol. 13(12), pages 1-23, June.
    15. Jani, D.B. & Mishra, Manish & Sahoo, P.K., 2016. "Solid desiccant air conditioning – A state of the art review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 60(C), pages 1451-1469.
    16. Ruivo, Celestino R. & Angrisani, Giovanni & Minichiello, Francesco, 2015. "Influence of the rotation speed on the effectiveness parameters of a desiccant wheel: An assessment using experimental data and manufacturer software," Renewable Energy, Elsevier, vol. 76(C), pages 484-493.
    17. Campaniço, Hugo & Soares, Pedro M.M. & Hollmuller, Pierre & Cardoso, Rita M., 2016. "Climatic cooling potential and building cooling demand savings: High resolution spatiotemporal analysis of direct ventilation and evaporative cooling for the Iberian Peninsula," Renewable Energy, Elsevier, vol. 85(C), pages 766-776.
    18. Sheng, Ying & Zhang, Yufeng & Zhang, Ge, 2015. "Simulation and energy saving analysis of high temperature heat pump coupling to desiccant wheel air conditioning system," Energy, Elsevier, vol. 83(C), pages 583-596.
    19. Zheng, X. & Ge, T.S. & Wang, R.Z., 2014. "Recent progress on desiccant materials for solid desiccant cooling systems," Energy, Elsevier, vol. 74(C), pages 280-294.
    20. La, D. & Li, Y. & Dai, Y.J. & Ge, T.S. & Wang, R.Z., 2012. "Development of a novel rotary desiccant cooling cycle with isothermal dehumidification and regenerative evaporative cooling using thermodynamic analysis method," Energy, Elsevier, vol. 44(1), pages 778-791.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:74:y:2014:i:c:p:555-566. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.