IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v143y2018icp114-127.html
   My bibliography  Save this article

Investigation on solar assisted liquid desiccant dehumidifier and evaporative cooling system for fresh air treatment

Author

Listed:
  • Chen, Yi
  • Yang, Hongxing
  • Luo, Yimo

Abstract

The widely used semi-centralized air conditioning (A/C) system consisting of independent fresh air system and fan coil system suffers from huge energy consumption, especially for fresh air treatment. Therefore, a liquid desiccant dehumidifier and regenerative indirect evaporative cooling (LDD-RIEC) system is proposed for fresh air treatment. The fresh air is handled by the LDD-RIEC system in which no electricity-intensive compressor involves. The hot and humid fresh air is firstly dehumidified by LDD and then sensibly cooled by RIEC. The thermal energy captured by solar collectors is used for desiccant solution regeneration. Indoor return air is cooled by fan coils of a mechanical cooling system. The system performance is analyzed by solving the heat and mass transfer equations of each component integrally in a closed loop. Focus is placed on discussing the influences of solar collector area and inlet air conditions, and optimizing the extraction air ratio of RIEC. The energy saving ratio is quantitatively evaluated with respect to a conventional A/C system. Results reveal that the optimal extraction ratio is 0.3 considering the interacted influence of dehumidifier, regenerator, RIEC and solar collector. The energy saving ratio ranges from 22.4% to 53.2% under various inlet air conditions.

Suggested Citation

  • Chen, Yi & Yang, Hongxing & Luo, Yimo, 2018. "Investigation on solar assisted liquid desiccant dehumidifier and evaporative cooling system for fresh air treatment," Energy, Elsevier, vol. 143(C), pages 114-127.
  • Handle: RePEc:eee:energy:v:143:y:2018:i:c:p:114-127
    DOI: 10.1016/j.energy.2017.10.124
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544217318297
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2017.10.124?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Duan, Zhiyin & Zhan, Changhong & Zhang, Xingxing & Mustafa, Mahmud & Zhao, Xudong & Alimohammadisagvand, Behrang & Hasan, Ala, 2012. "Indirect evaporative cooling: Past, present and future potentials," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(9), pages 6823-6850.
    2. Qi, Ronghui & Lu, Lin, 2014. "Energy consumption and optimization of internally cooled/heated liquid desiccant air-conditioning system: A case study in Hong Kong," Energy, Elsevier, vol. 73(C), pages 801-808.
    3. Kim, Min-Hwi & Park, Jun-Seok & Jeong, Jae-Weon, 2013. "Energy saving potential of liquid desiccant in evaporative-cooling-assisted 100% outdoor air system," Energy, Elsevier, vol. 59(C), pages 726-736.
    4. Mohammad, Abdulrahman Th. & Bin Mat, Sohif & Sulaiman, M.Y. & Sopian, K. & Al-abidi, Abduljalil A., 2013. "Survey of hybrid liquid desiccant air conditioning systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 20(C), pages 186-200.
    5. La, D. & Dai, Y.J. & Li, Y. & Tang, Z.Y. & Ge, T.S. & Wang, R.Z., 2013. "An experimental investigation on the integration of two-stage dehumidification and regenerative evaporative cooling," Applied Energy, Elsevier, vol. 102(C), pages 1218-1228.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Chai, Shaowei & Sun, Xiangyu & Zhao, Yao & Dai, Yanjun, 2019. "Experimental investigation on a fresh air dehumidification system using heat pump with desiccant coated heat exchanger," Energy, Elsevier, vol. 171(C), pages 306-314.
    2. Gao, D.C. & Sun, Y.J. & Ma, Z. & Ren, H., 2021. "A review on integration and design of desiccant air-conditioning systems for overall performance improvements," Renewable and Sustainable Energy Reviews, Elsevier, vol. 141(C).
    3. Beccali, M. & Finocchiaro, P. & Ippolito, M.G. & Leone, G. & Panno, D. & Zizzo, G., 2018. "Analysis of some renewable energy uses and demand side measures for hotels on small Mediterranean islands: A case study," Energy, Elsevier, vol. 157(C), pages 106-114.
    4. Dong, Chuanshuai & Lu, Lin & Wen, Tao, 2018. "Investigating dehumidification performance of solar-assisted liquid desiccant dehumidifiers considering different surface properties," Energy, Elsevier, vol. 164(C), pages 978-994.
    5. Liang, Jyun-De & Huang, Bo-Hao & Chiang, Yuan-Ching & Chen, Sih-Li, 2020. "Experimental investigation of a liquid desiccant dehumidification system integrated with shallow geothermal energy," Energy, Elsevier, vol. 191(C).
    6. Jiangjiang Wang & Rujing Yan & Zhuang Wang & Xutao Zhang & Guohua Shi, 2018. "Thermal Performance Analysis of an Absorption Cooling System Based on Parabolic Trough Solar Collectors," Energies, MDPI, vol. 11(10), pages 1-17, October.
    7. Yang, Zili & Tao, Ruiyang & Ni, Hui & Zhong, Ke & Lian, Zhiwei, 2019. "Performance study of the internally-cooled ultrasonic atomization liquid desiccant dehumidification system," Energy, Elsevier, vol. 175(C), pages 745-757.
    8. Ji Li & Yuanwei Liu & Ruixue Zhang & Zhijian Liu & Wei Xu & Biao Qiao & Xiaomei Feng, 2018. "Load Distribution of Semi-Central Evaporative Cooling Air-Conditioning System Based on the TRNSYS Platform," Energies, MDPI, vol. 11(5), pages 1-15, May.
    9. Li, Hongxuan & Zou, Tonghua & Han, Xiaowan & Dai, Baomin & Liu, Jia, 2023. "Numerical and experimental study on the regeneration performance of a liquid desiccant system coupled with rotating packed bed and vacuum," Applied Energy, Elsevier, vol. 336(C).
    10. Qing Cheng & Han Wang & Lin Zhu & Yao Chen, 2023. "A current efficiency model coupled with desiccant molecular weight for electrodialysis regeneration in liquid desiccant air-conditioning systems," Energy & Environment, , vol. 34(4), pages 909-926, June.
    11. Yang, Hongxing & Shi, Wenchao & Chen, Yi & Min, Yunran, 2021. "Research development of indirect evaporative cooling technology: An updated review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 145(C).
    12. Chen, Yi & Yan, Huaxia & Luo, Yimo & Yang, Hongxing, 2019. "A proportional–integral (PI) law based variable speed technology for temperature control in indirect evaporative cooling system," Applied Energy, Elsevier, vol. 251(C), pages 1-1.
    13. Açıkkalp, Emin & Caliskan, Hakan & Hong, Hiki & Piao, Hongjie & Seung, Dohyun, 2022. "Extended exergy analysis of a photovoltaic-thermal (PVT) module based desiccant air cooling system for buildings," Applied Energy, Elsevier, vol. 323(C).
    14. Chen, Yi & Yan, Huaxia & Yang, Hongxing, 2018. "Comparative study of on-off control and novel high-low control of regenerative indirect evaporative cooler (RIEC)," Applied Energy, Elsevier, vol. 225(C), pages 233-243.
    15. Oh, Seung Jin & Shahzad, Muhammad Wakil & Burhan, Muhammad & Chun, Wongee & Kian Jon, Chua & KumJa, M. & Ng, Kim Choon, 2019. "Approaches to energy efficiency in air conditioning: A comparative study on purge configurations for indirect evaporative cooling," Energy, Elsevier, vol. 168(C), pages 505-515.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Mahmood, Muhammad H. & Sultan, Muhammad & Miyazaki, Takahiko & Koyama, Shigeru & Maisotsenko, Valeriy S., 2016. "Overview of the Maisotsenko cycle – A way towards dew point evaporative cooling," Renewable and Sustainable Energy Reviews, Elsevier, vol. 66(C), pages 537-555.
    2. Cui, X. & Islam, M.R. & Mohan, B. & Chua, K.J., 2016. "Theoretical analysis of a liquid desiccant based indirect evaporative cooling system," Energy, Elsevier, vol. 95(C), pages 303-312.
    3. Hwang, Won-Baek & Choi, Sun & Lee, Dae-Young, 2017. "In-depth analysis of the performance of hybrid desiccant cooling system incorporated with an electric heat pump," Energy, Elsevier, vol. 118(C), pages 324-332.
    4. Park, Joon-Young & Kim, Beom-Jun & Yoon, Soo-Yeol & Byon, Yoo-Suk & Jeong, Jae-Weon, 2019. "Experimental analysis of dehumidification performance of an evaporative cooling-assisted internally cooled liquid desiccant dehumidifier," Applied Energy, Elsevier, vol. 235(C), pages 177-185.
    5. Wang, Xinli & Cai, Wenjian & Lu, Jiangang & Sun, Youxian & Zhao, Lei, 2015. "Model-based optimization strategy of chiller driven liquid desiccant dehumidifier with genetic algorithm," Energy, Elsevier, vol. 82(C), pages 939-948.
    6. Abdel-Salam, Ahmed H. & Simonson, Carey J., 2016. "State-of-the-art in liquid desiccant air conditioning equipment and systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 1152-1183.
    7. Kojok, Farah & Fardoun, Farouk & Younes, Rafic & Outbib, Rachid, 2016. "Hybrid cooling systems: A review and an optimized selection scheme," Renewable and Sustainable Energy Reviews, Elsevier, vol. 65(C), pages 57-80.
    8. Cui, X. & Chua, K.J. & Yang, W.M., 2014. "Numerical simulation of a novel energy-efficient dew-point evaporative air cooler," Applied Energy, Elsevier, vol. 136(C), pages 979-988.
    9. Kim, Min-Hwi & Ham, Sang-Woo & Park, Jun-Seok & Jeong, Jae-Weon, 2014. "Impact of integrated hot water cooling and desiccant-assisted evaporative cooling systems on energy savings in a data center," Energy, Elsevier, vol. 78(C), pages 384-396.
    10. Chen, Yi & Yan, Huaxia & Yang, Hongxing, 2018. "Comparative study of on-off control and novel high-low control of regenerative indirect evaporative cooler (RIEC)," Applied Energy, Elsevier, vol. 225(C), pages 233-243.
    11. Shukla, D.L. & Modi, K.V., 2022. "Influence of distinct input parameters on performance indices of dehumidifier, regenerator and on liquid desiccant-operated evaporative cooling system – A critical review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 168(C).
    12. Lin, Jie & Bui, Duc Thuan & Wang, Ruzhu & Chua, Kian Jon, 2018. "On the fundamental heat and mass transfer analysis of the counter-flow dew point evaporative cooler," Applied Energy, Elsevier, vol. 217(C), pages 126-142.
    13. Yang, Zili & Zhang, Kaisheng & Lian, Zhiwei & Zhang, Huibo, 2016. "Sensitivity and stability analysis on the performance of ultrasonic atomization liquid desiccant dehumidification system," Energy, Elsevier, vol. 112(C), pages 1169-1183.
    14. Jradi, M. & Riffat, S., 2014. "Experimental and numerical investigation of a dew-point cooling system for thermal comfort in buildings," Applied Energy, Elsevier, vol. 132(C), pages 524-535.
    15. Joon-Young Park & Jae-Weon Jeong, 2017. "Operating Energy Savings of a Liquid Desiccant and Evaporative Cooling-Assisted Air-Handling System in Marine Applications," Energies, MDPI, vol. 10(4), pages 1-19, April.
    16. Chen, Chih-Hao & Hsu, Chien-Yeh & Chen, Chih-Chieh & Chiang, Yuan-Ching & Chen, Sih-Li, 2016. "Silica gel/polymer composite desiccant wheel combined with heat pump for air-conditioning systems," Energy, Elsevier, vol. 94(C), pages 87-99.
    17. Oliveira, Cíntia Carla Melgaço de & Brittes, José Luiz Pereira & Silveira Junior, Vivaldo, 2019. "Dynamic operating conditions strategy for water hybrid cooling under variable heating demand," Applied Energy, Elsevier, vol. 237(C), pages 635-645.
    18. Ji Li & Yuanwei Liu & Ruixue Zhang & Zhijian Liu & Wei Xu & Biao Qiao & Xiaomei Feng, 2018. "Load Distribution of Semi-Central Evaporative Cooling Air-Conditioning System Based on the TRNSYS Platform," Energies, MDPI, vol. 11(5), pages 1-15, May.
    19. Ham, Sang-Woo & Jeong, Jae-Weon, 2016. "DPHX (dew point evaporative heat exchanger): System design and performance analysis," Energy, Elsevier, vol. 101(C), pages 132-145.
    20. Xie, Ying & Zhang, Tao & Liu, Xiaohua, 2016. "Performance investigation of a counter-flow heat pump driven liquid desiccant dehumidification system," Energy, Elsevier, vol. 115(P1), pages 446-457.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:143:y:2018:i:c:p:114-127. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.