IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i3p982-d737123.html
   My bibliography  Save this article

Fixed Fiber Light Guide System with Concave Outlet Concentrators

Author

Listed:
  • Bangdi Zhou

    (School of Physical Science and Technology, Guangxi University, Nanning 530004, China)

  • Kaiyan He

    (School of Physical Science and Technology, Guangxi University, Nanning 530004, China)

  • Ziqian Chen

    (School of Physical Science and Technology, Guangxi University, Nanning 530004, China)

  • Shuiku Zhong

    (School of Physical Science and Technology, Guangxi University, Nanning 530004, China)

Abstract

Because a traditional optical fiber light guiding system includes a tracking device, it also inevitably has a complex structure, high construction and maintenance costs, short life span and low reliability. Although several types have been developed for decades, there are no successful products on the market. The biggest cause of the problem is that all traditional optical fiber light guiding systems must have a tracking device. This paper studies a solar fiber optic guide system without a tracking device, hoping to solve this problem. A fixed fiber light guide system using concave outlet concentrators as its receiving unit is proposed. The structure and working principle of the concave outlet concentrator, the receiving unit and the light guide system are introduced. With optical simulation software and the actual sunlight experimental method, this paper first discusses the conceptual design of the concentrator, then studies the transmission efficiency curve of the receiving unit with different angles of incident light, and finally tests the output illuminance of the whole system in actual sunlight. Field test results show that when the average sunshine intensity is about 800 W/m 2 , the system has an output of nearly 300 lux at 0.4 m in front of the outlet end of the fiber bundle with only 3.11 × 10 − 2 m 2 receiving area. This illumination has been able to meet people’s daily lighting requirements. The results of computer simulation and actual sunlight experiments show that this fixed optical fiber light guide system with non-tracing structure is feasible. The absence of a tracking structure means that all moving parts of the system are completely discarded. This greatly improves the working reliability and operation life of the light guide system, and greatly reduces the maintenance and operating costs.

Suggested Citation

  • Bangdi Zhou & Kaiyan He & Ziqian Chen & Shuiku Zhong, 2022. "Fixed Fiber Light Guide System with Concave Outlet Concentrators," Energies, MDPI, vol. 15(3), pages 1-16, January.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:3:p:982-:d:737123
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/3/982/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/3/982/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Wong, Irene & Yang, H.X., 2012. "Introducing natural lighting into the enclosed lift lobbies of highrise buildings by remote source lighting system," Applied Energy, Elsevier, vol. 90(1), pages 225-232.
    2. Darula, Stanislav & Kittler, Richard & Kocifaj, Miroslav, 2010. "Luminous effectiveness of tubular light-guides in tropics," Applied Energy, Elsevier, vol. 87(11), pages 3460-3466, November.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Sreelakshmi, Kavuthimadathil & Ramamurthy, K., 2022. "Review on fibre-optic-based daylight enhancement systems in buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 163(C).

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Wang, Xiaoxiao & Liu, Xiangfeng, 2015. "Blue Star: The proposed energy efficient tall building in Chicago and vertical city strategies," Renewable and Sustainable Energy Reviews, Elsevier, vol. 47(C), pages 241-259.
    2. Pattarapanitchai, S. & Janjai, S. & Tohsing, K. & Prathumsit, J., 2015. "A technique to map monthly average global illuminance from satellite data in the tropics using a simple semi-empirical model," Renewable Energy, Elsevier, vol. 74(C), pages 170-175.
    3. Salata, Ferdinando & Golasi, Iacopo & di Salvatore, Maicol & de Lieto Vollaro, Andrea, 2016. "Energy and reliability optimization of a system that combines daylighting and artificial sources. A case study carried out in academic buildings," Applied Energy, Elsevier, vol. 169(C), pages 250-266.
    4. Atthakorn Thongtha & Peeranat Laphom & Jiraphorn Mahawan, 2023. "Investigation of the Efficacy of Horizontal Hollow Light Tubes for Energy Conservation in Illuminating Buildings," Energies, MDPI, vol. 16(22), pages 1-19, November.
    5. Azis, Shazmin Shareena Ab., 2021. "Improving present-day energy savings among green building sector in Malaysia using benefit transfer approach: Cooling and lighting loads," Renewable and Sustainable Energy Reviews, Elsevier, vol. 137(C).
    6. Mangkuto, R.A. & Wang, S. & Meerbeek, B.W. & Aries, M.B.C. & van Loenen, E.J., 2014. "Lighting performance and electrical energy consumption of a virtual window prototype," Applied Energy, Elsevier, vol. 135(C), pages 261-273.
    7. Cristina Baglivo & Marina Bonomolo & Paolo Maria Congedo, 2019. "Modeling of Light Pipes for the Optimal Disposition in Buildings," Energies, MDPI, vol. 12(22), pages 1-28, November.
    8. Janjai, Serm & Plaon, Piyanuch, 2011. "Estimation of sky luminance in the tropics using artificial neural networks: Modeling and performance comparison with the CIE model," Applied Energy, Elsevier, vol. 88(3), pages 840-847, March.
    9. Freire, Roberto Zanetti & Mazuroski, Walter & Abadie, Marc Olivier & Mendes, Nathan, 2011. "Capacitive effect on the heat transfer through building glazing systems," Applied Energy, Elsevier, vol. 88(12), pages 4310-4319.
    10. Gago, E.J. & Muneer, T. & Knez, M. & Köster, H., 2015. "Natural light controls and guides in buildings. Energy saving for electrical lighting, reduction of cooling load," Renewable and Sustainable Energy Reviews, Elsevier, vol. 41(C), pages 1-13.
    11. Mangkuto, Rizki A. & Rohmah, Mardliyahtur & Asri, Anindya Dian, 2016. "Design optimisation for window size, orientation, and wall reflectance with regard to various daylight metrics and lighting energy demand: A case study of buildings in the tropics," Applied Energy, Elsevier, vol. 164(C), pages 211-219.
    12. Xia, Longyu & Wei, Gaosheng & Wang, Gang & Cui, Liu & Du, Xiaoze, 2023. "Research on combined solar fiber lighting and photovoltaic power generation system based on the spectral splitting technology," Applied Energy, Elsevier, vol. 333(C).
    13. Barbón, A. & Sánchez-Rodríguez, J.A. & Bayón, L. & Barbón, N., 2018. "Development of a fiber daylighting system based on a small scale linear Fresnel reflector: Theoretical elements," Applied Energy, Elsevier, vol. 212(C), pages 733-745.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:3:p:982-:d:737123. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.