This article presents the state of the knowledge on the thermal analysis of double skin facades with integrated photovoltaic (PV) panels called the Building Integrated Photovoltaics (BIPV) in terms of the published studies carried out on these systems. The idea of integration of the PV panels by replacing building elements, increase the prospects of the renewable energy systems. Taking also into account the need to use more renewable energy systems in buildings, the investigation of the BIPV systems to improve their performance is of a great importance. The literature studies are separated into experimental and theoretical for naturally ventilated systems and mechanically ventilated with external means e.g. fan use. It is concluded that most researchers studied the systems with mechanical ventilation rather than the systems with natural ventilation because the latter are more complex in terms of the air flow behaviour in the air duct. Additionally, various researchers proposed Nu number correlations and convective heat transfer correlation under several assumptions and conditions every time, for different range or Ra number which are presented and compared in this paper.

Suggested Citation

  • Agathokleous, Rafaela A. & Kalogirou, Soteris A., 2016. "Double skin facades (DSF) and building integrated photovoltaics (BIPV): A review of configurations and heat transfer characteristics," Renewable Energy, Elsevier, vol. 89(C), pages 743-756.
  • Handle: RePEc:eee:renene:v:89:y:2016:i:c:p:743-756
    DOI: 10.1016/j.renene.2015.12.043
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148115305474
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2015.12.043?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Zogou, Olympia & Stapountzis, Herricos, 2011. "Experimental validation of an improved concept of building integrated photovoltaic panels," Renewable Energy, Elsevier, vol. 36(12), pages 3488-3498.
    2. Bazilian, Morgan D. & Kamalanathan, Harry & Prasad, D.K., 2002. "Thermographic analysis of a building integrated photovoltaic system," Renewable Energy, Elsevier, vol. 26(3), pages 449-461.
    3. Zogou, Olympia & Stapountzis, Herricos, 2011. "Energy analysis of an improved concept of integrated PV panels in an office building in central Greece," Applied Energy, Elsevier, vol. 88(3), pages 853-866, March.
    4. De Gracia, Alvaro & Castell, Albert & Navarro, Lidia & Oró, Eduard & Cabeza, Luisa F., 2013. "Numerical modelling of ventilated facades: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 22(C), pages 539-549.
    5. Gan, Guohui, 2009. "Effect of air gap on the performance of building-integrated photovoltaics," Energy, Elsevier, vol. 34(7), pages 913-921.
    6. Kaiser, A.S. & Zamora, B. & Mazón, R. & García, J.R. & Vera, F., 2014. "Experimental study of cooling BIPV modules by forced convection in the air channel," Applied Energy, Elsevier, vol. 135(C), pages 88-97.
    7. Zogou, Olympia & Stapountzis, Herricos, 2012. "Flow and heat transfer inside a PV/T collector for building application," Applied Energy, Elsevier, vol. 91(1), pages 103-115.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Yang, Tingting & Athienitis, Andreas K., 2016. "A review of research and developments of building-integrated photovoltaic/thermal (BIPV/T) systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 66(C), pages 886-912.
    2. Yang, Tingting & Athienitis, Andreas K., 2015. "Experimental investigation of a two-inlet air-based building integrated photovoltaic/thermal (BIPV/T) system," Applied Energy, Elsevier, vol. 159(C), pages 70-79.
    3. Vassiliades, C. & Agathokleous, R. & Barone, G. & Forzano, C. & Giuzio, G.F. & Palombo, A. & Buonomano, A. & Kalogirou, S., 2022. "Building integration of active solar energy systems: A review of geometrical and architectural characteristics," Renewable and Sustainable Energy Reviews, Elsevier, vol. 164(C).
    4. Eke, Rustu & Senturk, Ali, 2013. "Monitoring the performance of single and triple junction amorphous silicon modules in two building integrated photovoltaic (BIPV) installations," Applied Energy, Elsevier, vol. 109(C), pages 154-162.
    5. Zogou, Olympia & Stapountzis, Herricos, 2012. "Flow and heat transfer inside a PV/T collector for building application," Applied Energy, Elsevier, vol. 91(1), pages 103-115.
    6. Assoa, Ya Brigitte & Sauzedde, François & Boillot, Benjamin, 2018. "Numerical parametric study of the thermal and electrical performance of a BIPV/T hybrid collector for drying applications," Renewable Energy, Elsevier, vol. 129(PA), pages 121-131.
    7. Buonomano, Annamaria & Calise, Francesco & Palombo, Adolfo & Vicidomini, Maria, 2016. "BIPVT systems for residential applications: An energy and economic analysis for European climates," Applied Energy, Elsevier, vol. 184(C), pages 1411-1431.
    8. Abdel Rahman Elbakheit & Sahl Waheeb & Ahmed Mahmoud, 2022. "A Ducted Photovoltaic Façade Unit with Forced Convection Cooling," Sustainability, MDPI, vol. 14(19), pages 1-13, October.
    9. Ibañez-Puy, María & Vidaurre-Arbizu, Marina & Sacristán-Fernández, José Antonio & Martín-Gómez, César, 2017. "Opaque Ventilated Façades: Thermal and energy performance review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 79(C), pages 180-191.
    10. Zogou, Olympia & Stapountzis, Herricos, 2011. "Experimental validation of an improved concept of building integrated photovoltaic panels," Renewable Energy, Elsevier, vol. 36(12), pages 3488-3498.
    11. Rounis, Efstratios Dimitrios & Athienitis, Andreas & Stathopoulos, Theodore, 2021. "Review of air-based PV/T and BIPV/T systems - Performance and modelling," Renewable Energy, Elsevier, vol. 163(C), pages 1729-1753.
    12. Gholampour, Maysam & Ameri, Mehran, 2016. "Energy and exergy analyses of Photovoltaic/Thermal flat transpired collectors: Experimental and theoretical study," Applied Energy, Elsevier, vol. 164(C), pages 837-856.
    13. Yiqing Dai & Yu Bai, 2020. "Performance Improvement for Building Integrated Photovoltaics in Practice: A Review," Energies, MDPI, vol. 14(1), pages 1-22, December.
    14. Pathak, M.J.M. & Sanders, P.G. & Pearce, J.M., 2014. "Optimizing limited solar roof access by exergy analysis of solar thermal, photovoltaic, and hybrid photovoltaic thermal systems," Applied Energy, Elsevier, vol. 120(C), pages 115-124.
    15. Athienitis, Andreas K. & Barone, Giovanni & Buonomano, Annamaria & Palombo, Adolfo, 2018. "Assessing active and passive effects of façade building integrated photovoltaics/thermal systems: Dynamic modelling and simulation," Applied Energy, Elsevier, vol. 209(C), pages 355-382.
    16. Dehra, Himanshu, 2017. "An investigation on energy performance assessment of a photovoltaic solar wall under buoyancy-induced and fan-assisted ventilation system," Applied Energy, Elsevier, vol. 191(C), pages 55-74.
    17. Arkar, C. & Žižak, T. & Domjan, S. & Medved, S., 2020. "Dynamic parametric models for the holistic evaluation of semi-transparent photovoltaic/thermal façade with latent storage inserts," Applied Energy, Elsevier, vol. 280(C).
    18. Abbas, Sajid & Yuan, Yanping & Zhou, Jinzhi & Hassan, Atazaz & Yu, Min & Yasheng, Ji, 2022. "Experimental and analytical analysis of the impact of different base plate materials and design parameters on the performance of the photovoltaic/thermal system," Renewable Energy, Elsevier, vol. 187(C), pages 522-536.
    19. Barbosa, Sabrina & Ip, Kenneth, 2014. "Perspectives of double skin façades for naturally ventilated buildings: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 40(C), pages 1019-1029.
    20. Kaplanis, S. & Kaplani, E. & Kaldellis, J.K., 2022. "PV temperature and performance prediction in free-standing, BIPV and BAPV incorporating the effect of temperature and inclination on the heat transfer coefficients and the impact of wind, efficiency a," Renewable Energy, Elsevier, vol. 181(C), pages 235-249.

    More about this item

    Keywords

    BIPV; BIPV/T; DSSF; DSVF; PV; Solar façades;
    All these keywords.

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:89:y:2016:i:c:p:743-756. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.