Experimental investigations on ejector refrigeration system with ammonia

Author

Listed:
  • Sankarlal, T.
  • Mani, A.

Abstract

A vapor ejector refrigeration system has been designed and developed to operate with ammonia. In this paper, performance of ejector refrigeration system has been experimentally studied with three different area ratio ejectors by varying operational parameters namely generator, condenser and evaporator temperatures. Effect of non-dimensional parameters like compression ratio, expansion ratio and area ratio on the system performance is studied. Entrainment ratio and coefficient of performance of the system increase with increase in ejector area ratio and expansion ratio and they increase with decrease in compression ratio.

Suggested Citation

  • Sankarlal, T. & Mani, A., 2007. "Experimental investigations on ejector refrigeration system with ammonia," Renewable Energy, Elsevier, vol. 32(8), pages 1403-1413.
  • Handle: RePEc:eee:renene:v:32:y:2007:i:8:p:1403-1413
    DOI: 10.1016/j.renene.2006.05.008
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148106001194
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2006.05.008?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Yan, Jia & Cai, Wenjian & Zhao, Lei & Li, Yanzhong & Lin, Chen, 2013. "Performance evaluation of a combined ejector-vapor compression cycle," Renewable Energy, Elsevier, vol. 55(C), pages 331-337.
    2. Chen, Xiangjie & Omer, Siddig & Worall, Mark & Riffat, Saffa, 2013. "Recent developments in ejector refrigeration technologies," Renewable and Sustainable Energy Reviews, Elsevier, vol. 19(C), pages 629-651.
    3. Zeyghami, Mehdi & Goswami, D. Yogi & Stefanakos, Elias, 2015. "A review of solar thermo-mechanical refrigeration and cooling methods," Renewable and Sustainable Energy Reviews, Elsevier, vol. 51(C), pages 1428-1445.
    4. Hamza K. Mukhtar & Saud Ghani, 2021. "Hybrid Ejector-Absorption Refrigeration Systems: A Review," Energies, MDPI, vol. 14(20), pages 1-31, October.
    5. Mouhammad El Hassan, 2022. "System COP of Ejector-Based Ground-Source Heat Pumps," Energies, MDPI, vol. 15(22), pages 1-14, November.
    6. Ramesh, A.S. & Sekhar, S. Joseph, 2018. "Experimental and numerical investigations on the effect of suction chamber angle and nozzle exit position of a steam-jet ejector," Energy, Elsevier, vol. 164(C), pages 1097-1113.
    7. Wang, Jiangfeng & Dai, Yiping & Gao, Lin & Ma, Shaolin, 2009. "A new combined cooling, heating and power system driven by solar energy," Renewable Energy, Elsevier, vol. 34(12), pages 2780-2788.
    8. Besagni, Giorgio & Mereu, Riccardo & Inzoli, Fabio, 2016. "Ejector refrigeration: A comprehensive review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 53(C), pages 373-407.
    9. Van Vu Nguyen & Szabolcs Varga & Vaclav Dvorak, 2019. "HFO1234ze(e) As an Alternative Refrigerant for Ejector Cooling Technology," Energies, MDPI, vol. 12(21), pages 1-14, October.
    10. Yan, Jia & Cai, Wenjian & Li, Yanzhong, 2012. "Geometry parameters effect for air-cooled ejector cooling systems with R134a refrigerant," Renewable Energy, Elsevier, vol. 46(C), pages 155-163.
    11. Yu, Jianlin & Du, Zhenxing, 2010. "Theoretical study of a transcritical ejector refrigeration cycle with refrigerant R143a," Renewable Energy, Elsevier, vol. 35(9), pages 2034-2039.
    12. Abed, Azher M. & Alghoul, M.A. & Sopian, K. & Majdi, Hasan Sh. & Al-Shamani, Ali Najah & Muftah, A.F., 2017. "Enhancement aspects of single stage absorption cooling cycle: A detailed review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 77(C), pages 1010-1045.
    13. Zhang, Kun & Chen, Xue & Markides, Christos N. & Yang, Yong & Shen, Shengqiang, 2016. "Evaluation of ejector performance for an organic Rankine cycle combined power and cooling system," Applied Energy, Elsevier, vol. 184(C), pages 404-412.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:32:y:2007:i:8:p:1403-1413. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.