IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v158y2018icp164-180.html
   My bibliography  Save this article

Theoretical investigation on energy storage characteristics of a solar liquid desiccant air conditioning system in Egypt

Author

Listed:
  • Kabeel, A.E.
  • Khalil, A.
  • Elsayed, S.S.
  • Alatyar, A.M.

Abstract

This work presents theoretical study of a standalone outdoor liquid desiccant air conditioning (LDAC) system assisted by solar energy. The liquid desiccant dehumidification cycle was integrated with a double indirect evaporative air cooler and a regenerative air heat recovery. The double indirect evaporative air cooler was used to recover heat from the return air, while air-air heat exchanger was used to recover heat from air leaving the regenerator. A water-in-glass evacuated tube solar collector was used to supply the system with solar heat. The remaining required heat is provided by natural gas fired boiler. The system was simulated by transient model under thermal energy storage, thermochemical energy storage and combined thermal and thermochemical energy storage modes.

Suggested Citation

  • Kabeel, A.E. & Khalil, A. & Elsayed, S.S. & Alatyar, A.M., 2018. "Theoretical investigation on energy storage characteristics of a solar liquid desiccant air conditioning system in Egypt," Energy, Elsevier, vol. 158(C), pages 164-180.
  • Handle: RePEc:eee:energy:v:158:y:2018:i:c:p:164-180
    DOI: 10.1016/j.energy.2018.06.014
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544218310673
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2018.06.014?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Kabeel, A.E. & Khalil, A. & Elsayed, S.S. & Alatyar, A.M., 2018. "Dynamic behaviour simulation of a liquid desiccant dehumidification system," Energy, Elsevier, vol. 144(C), pages 456-471.
    2. Hsu, Shyr Tzer & Lavan, Zalman & Worek, William M., 1989. "Optimization of wet-surface heat exchangers," Energy, Elsevier, vol. 14(11), pages 757-770.
    3. Audah, N. & Ghaddar, N. & Ghali, K., 2011. "Optimized solar-powered liquid desiccant system to supply building fresh water and cooling needs," Applied Energy, Elsevier, vol. 88(11), pages 3726-3736.
    4. Kabeel, A.E. & Khalil, A. & Elsayed, S.S. & Alatyar, A.M., 2015. "Modified mathematical model for evaluating the performance of water-in-glass evacuated tube solar collector considering tube shading effect," Energy, Elsevier, vol. 89(C), pages 24-34.
    5. Lin, J. & Thu, K. & Bui, T.D. & Wang, R.Z. & Ng, K.C. & Kumja, M. & Chua, K.J., 2016. "Unsteady-state analysis of a counter-flow dew point evaporative cooling system," Energy, Elsevier, vol. 113(C), pages 172-185.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Liang, Jyun-De & Huang, Bo-Hao & Chiang, Yuan-Ching & Chen, Sih-Li, 2020. "Experimental investigation of a liquid desiccant dehumidification system integrated with shallow geothermal energy," Energy, Elsevier, vol. 191(C).
    2. Qing Cheng & Han Wang & Lin Zhu & Yao Chen, 2023. "A current efficiency model coupled with desiccant molecular weight for electrodialysis regeneration in liquid desiccant air-conditioning systems," Energy & Environment, , vol. 34(4), pages 909-926, June.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Lin, Jie & Bui, Duc Thuan & Wang, Ruzhu & Chua, Kian Jon, 2018. "On the fundamental heat and mass transfer analysis of the counter-flow dew point evaporative cooler," Applied Energy, Elsevier, vol. 217(C), pages 126-142.
    2. Pandelidis, Demis & Anisimov, Sergey & Rajski, Krzysztof & Brychcy, Ewa & Sidorczyk, Marek, 2017. "Performance comparison of the advanced indirect evaporative air coolers," Energy, Elsevier, vol. 135(C), pages 138-152.
    3. Angrisani, Giovanni & Roselli, Carlo & Sasso, Maurizio, 2015. "Experimental assessment of the energy performance of a hybrid desiccant cooling system and comparison with other air-conditioning technologies," Applied Energy, Elsevier, vol. 138(C), pages 533-545.
    4. Cui, X. & Islam, M.R. & Mohan, B. & Chua, K.J., 2016. "Theoretical analysis of a liquid desiccant based indirect evaporative cooling system," Energy, Elsevier, vol. 95(C), pages 303-312.
    5. Fekadu, Geleta & Subudhi, Sudhakar, 2018. "Renewable energy for liquid desiccants air conditioning system: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 93(C), pages 364-379.
    6. Ham, Sang-Woo & Jeong, Jae-Weon, 2016. "DPHX (dew point evaporative heat exchanger): System design and performance analysis," Energy, Elsevier, vol. 101(C), pages 132-145.
    7. Xie, Ying & Zhang, Tao & Liu, Xiaohua, 2016. "Performance investigation of a counter-flow heat pump driven liquid desiccant dehumidification system," Energy, Elsevier, vol. 115(P1), pages 446-457.
    8. Zhan, Changhong & Duan, Zhiyin & Zhao, Xudong & Smith, Stefan & Jin, Hong & Riffat, Saffa, 2011. "Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling – Paving the path toward sustainable cooling of buildings," Energy, Elsevier, vol. 36(12), pages 6790-6805.
    9. Chen, Xiaomeng & Yang, Xudong & Li, Muran, 2022. "Combining horizontal evacuated tubes with booster mirror reflector to achieve seasonal reverse output: Technical and experimental investigation," Renewable Energy, Elsevier, vol. 188(C), pages 450-464.
    10. Duan, Zhiyin & Zhan, Changhong & Zhang, Xingxing & Mustafa, Mahmud & Zhao, Xudong & Alimohammadisagvand, Behrang & Hasan, Ala, 2012. "Indirect evaporative cooling: Past, present and future potentials," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(9), pages 6823-6850.
    11. Demis Pandelidis & Sergey Anisimov & Paweł Drąg, 2017. "Performance Comparison between Selected Evaporative Air Coolers," Energies, MDPI, vol. 10(4), pages 1-20, April.
    12. Akhlaghi, Yousef Golizadeh & Ma, Xiaoli & Zhao, Xudong & Shittu, Samson & Li, Junming, 2019. "A statistical model for dew point air cooler based on the multiple polynomial regression approach," Energy, Elsevier, vol. 181(C), pages 868-881.
    13. Yin Bi & Yugang Wang & Xiaoli Ma & Xudong Zhao, 2017. "Investigation on the Energy Saving Potential of Using a Novel Dew Point Cooling System in Data Centres," Energies, MDPI, vol. 10(11), pages 1-21, October.
    14. Xu, Peng & Ma, Xiaoli & Zhao, Xudong & Fancey, Kevin, 2017. "Experimental investigation of a super performance dew point air cooler," Applied Energy, Elsevier, vol. 203(C), pages 761-777.
    15. Shukla, Dhruvin L. & Modi, Kalpesh V., 2017. "A technical review on regeneration of liquid desiccant using solar energy," Renewable and Sustainable Energy Reviews, Elsevier, vol. 78(C), pages 517-529.
    16. Chen, Xiaomeng & Wang, Yang & Yang, Xudong, 2023. "New biaxial approach to evaluate the optical performance of evacuated tube solar thermal collector," Energy, Elsevier, vol. 271(C).
    17. Liu, Wei & Gong, Yanfeng & Niu, Xiaofeng & Shen, Junjie & Kosonen, Risto, 2019. "Dynamic modeling of liquid-desiccant regenerator based on a state–space method," Applied Energy, Elsevier, vol. 240(C), pages 744-753.
    18. Lin, J. & Thu, K. & Bui, T.D. & Wang, R.Z. & Ng, K.C. & Kumja, M. & Chua, K.J., 2016. "Unsteady-state analysis of a counter-flow dew point evaporative cooling system," Energy, Elsevier, vol. 113(C), pages 172-185.
    19. Fathabadi, Hassan, 2020. "Novel solar collector: Evaluating the impact of nanoparticles added to the collector’s working fluid, heat transfer fluid temperature and flow rate," Renewable Energy, Elsevier, vol. 148(C), pages 1165-1173.
    20. Enteria, Napoleon & Yoshino, Hiroshi & Mochida, Akashi, 2013. "Review of the advances in open-cycle absorption air-conditioning systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 28(C), pages 265-289.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:158:y:2018:i:c:p:164-180. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.