IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v13y2019i1p146-d302611.html
   My bibliography  Save this article

Experimental Validation of a Numerical Model of a Ventilated Façade with Horizontal and Vertical Open Joints

Author

Listed:
  • María Nuria Sánchez

    (Department of Energy, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, 28040 Madrid, Spain)

  • Emanuela Giancola

    (Department of Energy, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, 28040 Madrid, Spain)

  • Eduardo Blanco

    (EDZE (Department of Energy), Universidad de Oviedo, 33271 Gijón (Asturias), Spain)

  • Silvia Soutullo

    (Department of Energy, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, 28040 Madrid, Spain)

  • María José Suárez

    (EDZE (Department of Energy), Universidad de Oviedo, 33271 Gijón (Asturias), Spain)

Abstract

Commercial and residential building is one of the four major final energy consumption and end-use sectors. In this sector, cooling loads represent an important part of the energy consumption, and therefore, they must be minimized, improving the energy efficiency of buildings. Ventilated façades are one of the most widely used passive elements that are integrated into buildings, precisely with the aim of reducing these loads. This reduction is due to the airflow induced in the air cavity by the buoyancy forces, when the solar radiation heats the outer layer of the façade. In the open joint ventilated facades (OJVF), ventilation is attained through the open joints between the panels composing the outer layer. Despite the steadily growing research in the characterization of this type of system, few studies combine the numerical modelling of OJVF with experimental results for the assessment of the airflow in the ventilated cavities. This paper experimentally validates a numerical simulation model of an OJVF. Firstly, the façade performance has been experimentally assessed in a laboratory model determining the temperatures in the panels and air gap and measuring the flow field at the gap using particle image velocimetry (PIV) techniques. Secondly, a numerical model has been developed using advanced Computational Fluid Dynamics (CFD) simulation tools. Finally, an experimental validation of the numerical model has been done. Experimental and numerical results are compared in different planes inside the ventilated cavity. The discrete ordinates (DO) radiation model and the k-ε renormalisation group (RNG) turbulence model better adjust the simulated results to the experimental ones.

Suggested Citation

  • María Nuria Sánchez & Emanuela Giancola & Eduardo Blanco & Silvia Soutullo & María José Suárez, 2019. "Experimental Validation of a Numerical Model of a Ventilated Façade with Horizontal and Vertical Open Joints," Energies, MDPI, vol. 13(1), pages 1-16, December.
  • Handle: RePEc:gam:jeners:v:13:y:2019:i:1:p:146-:d:302611
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/13/1/146/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/13/1/146/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Saadatian, Omidreza & Sopian, K. & Lim, C.H. & Asim, Nilofar & Sulaiman, M.Y., 2012. "Trombe walls: A review of opportunities and challenges in research and development," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(8), pages 6340-6351.
    2. Wang, Yang & Shukla, Ashish & Liu, Shuli, 2017. "A state of art review on methodologies for heat transfer and energy flow characteristics of the active building envelopes," Renewable and Sustainable Energy Reviews, Elsevier, vol. 78(C), pages 1102-1116.
    3. Harish, V.S.K.V. & Kumar, Arun, 2016. "A review on modeling and simulation of building energy systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 56(C), pages 1272-1292.
    4. Katsaprakakis, Dimitris Al. & Georgila, Klairi & Zidianakis, Georgios & Michopoulos, Apostolos & Psarras, Nikolaos & Christakis, Dimitris G. & Condaxakis, Constantinos & Kanouras, Spyros, 2017. "Energy upgrading of buildings. A holistic approach for the Natural History Museum of Crete, Greece," Renewable Energy, Elsevier, vol. 114(PB), pages 1306-1332.
    5. Luo, Yongqiang & Zhang, Ling & Wang, Xiliang & Xie, Lei & Liu, Zhongbing & Wu, Jing & Zhang, Yelin & He, Xihua, 2017. "A comparative study on thermal performance evaluation of a new double skin façade system integrated with photovoltaic blinds," Applied Energy, Elsevier, vol. 199(C), pages 281-293.
    6. María José Suárez López & Antonio José Gutiérrez Trashorras & Jorge Luis Parrondo Gayo & Eduardo Blanco Marigorta, 2018. "Analysis of an Attached Sunspace with a Thermal Inertia Floor," Energies, MDPI, vol. 11(5), pages 1-14, May.
    7. Zhang, Chong & Gang, Wenjie & Xu, Xinhua & Li, Liao & Wang, Jinbo, 2019. "Modelling, experimental test, and design of an active air permeable wall by utilizing the low-grade exhaust air," Applied Energy, Elsevier, vol. 240(C), pages 730-743.
    8. Ibañez-Puy, María & Vidaurre-Arbizu, Marina & Sacristán-Fernández, José Antonio & Martín-Gómez, César, 2017. "Opaque Ventilated Façades: Thermal and energy performance review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 79(C), pages 180-191.
    9. Halawa, Edward & Ghaffarianhoseini, Amirhosein & Ghaffarianhoseini, Ali & Trombley, Jeremy & Hassan, Norhaslina & Baig, Mirza & Yusoff, Safiah Yusmah & Azzam Ismail, Muhammad, 2018. "A review on energy conscious designs of building façades in hot and humid climates: Lessons for (and from) Kuala Lumpur and Darwin," Renewable and Sustainable Energy Reviews, Elsevier, vol. 82(P3), pages 2147-2161.
    10. Jomehzadeh, Fatemeh & Nejat, Payam & Calautit, John Kaiser & Yusof, Mohd Badruddin Mohd & Zaki, Sheikh Ahmad & Hughes, Ben Richard & Yazid, Muhammad Noor Afiq Witri Muhammad, 2017. "A review on windcatcher for passive cooling and natural ventilation in buildings, Part 1: Indoor air quality and thermal comfort assessment," Renewable and Sustainable Energy Reviews, Elsevier, vol. 70(C), pages 736-756.
    11. Ascione, Fabrizio & De Masi, Rosa Francesca & de Rossi, Filippo & Ruggiero, Silvia & Vanoli, Giuseppe Peter, 2016. "Optimization of building envelope design for nZEBs in Mediterranean climate: Performance analysis of residential case study," Applied Energy, Elsevier, vol. 183(C), pages 938-957.
    12. Sánchez, M.N. & Giancola, E. & Suárez, M.J. & Blanco, E. & Heras, M.R., 2017. "Experimental evaluation of the airflow behaviour in horizontal and vertical Open Joint Ventilated Facades using Stereo-PIV," Renewable Energy, Elsevier, vol. 109(C), pages 613-623.
    13. Zhang, Tiantian & Yang, Hongxing, 2019. "Flow and heat transfer characteristics of natural convection in vertical air channels of double-skin solar façades," Applied Energy, Elsevier, vol. 242(C), pages 107-120.
    14. Stazi, F. & Tomassoni, F. & Vegliò, A. & Di Perna, C., 2011. "Experimental evaluation of ventilated walls with an external clay cladding," Renewable Energy, Elsevier, vol. 36(12), pages 3373-3385.
    15. Huang, Junchao & Yu, Jinghua & Yang, Hongxing, 2018. "Effects of key factors on the heat insulation performance of a hollow block ventilated wall," Applied Energy, Elsevier, vol. 232(C), pages 409-423.
    16. Peci López, F. & Ruiz de Adana Santiago, M., 2015. "Sensitivity study of an opaque ventilated façade in the winter season in different climate zones in Spain," Renewable Energy, Elsevier, vol. 75(C), pages 524-533.
    17. Diallo, Thierno M.O. & Zhao, Xudong & Dugue, Antoine & Bonnamy, Paul & Javier Miguel, Francisco & Martinez, Asier & Theodosiou, Theodoros & Liu, Jing-Sheng & Brown, Nathan, 2017. "Numerical investigation of the energy performance of an Opaque Ventilated Façade system employing a smart modular heat recovery unit and a latent heat thermal energy system," Applied Energy, Elsevier, vol. 205(C), pages 130-152.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Liang, Ruobing & Pan, Qiangguang & Wang, Peng & Zhang, Jili, 2018. "Experiment research of solar PV/T cogeneration system on the building façade driven by a refrigerant pump," Energy, Elsevier, vol. 161(C), pages 744-752.
    2. Diallo, Thierno M.O. & Zhao, Xudong & Dugue, Antoine & Bonnamy, Paul & Javier Miguel, Francisco & Martinez, Asier & Theodosiou, Theodoros & Liu, Jing-Sheng & Brown, Nathan, 2017. "Numerical investigation of the energy performance of an Opaque Ventilated Façade system employing a smart modular heat recovery unit and a latent heat thermal energy system," Applied Energy, Elsevier, vol. 205(C), pages 130-152.
    3. Kočí, Jan & Kočí, Václav & Maděra, Jiří & Černý, Robert, 2019. "Effect of applied weather data sets in simulation of building energy demands: Comparison of design years with recent weather data," Renewable and Sustainable Energy Reviews, Elsevier, vol. 100(C), pages 22-32.
    4. Luo, Yongqiang & Zhang, Ling & Bozlar, Michael & Liu, Zhongbing & Guo, Hongshan & Meggers, Forrest, 2019. "Active building envelope systems toward renewable and sustainable energy," Renewable and Sustainable Energy Reviews, Elsevier, vol. 104(C), pages 470-491.
    5. Zhang, Haihua & Yang, Dong & Tam, Vivian W.Y. & Tao, Yao & Zhang, Guomin & Setunge, Sujeeva & Shi, Long, 2021. "A critical review of combined natural ventilation techniques in sustainable buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 141(C).
    6. Ibañez-Puy, María & Vidaurre-Arbizu, Marina & Sacristán-Fernández, José Antonio & Martín-Gómez, César, 2017. "Opaque Ventilated Façades: Thermal and energy performance review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 79(C), pages 180-191.
    7. Askari, Minoo & Jahangir, Mohammad Hossein, 2023. "Evaluation of thermal performance and energy efficiency of a Trombe wall improved with dual phase change materials," Energy, Elsevier, vol. 284(C).
    8. Silvia Soutullo & Emanuela Giancola & María Nuria Sánchez & José Antonio Ferrer & David García & María José Súarez & Jesús Ignacio Prieto & Elena Antuña-Yudego & Juan Luís Carús & Miguel Ángel Fernánd, 2020. "Methodology for Quantifying the Energy Saving Potentials Combining Building Retrofitting, Solar Thermal Energy and Geothermal Resources," Energies, MDPI, vol. 13(22), pages 1-25, November.
    9. Tao, Yao & Fang, Xiang & Chew, Michael Yit Lin & Zhang, Lihai & Tu, Jiyuan & Shi, Long, 2021. "Predicting airflow in naturally ventilated double-skin facades: theoretical analysis and modelling," Renewable Energy, Elsevier, vol. 179(C), pages 1940-1954.
    10. Al-Awsh, Waleed A. & Qasem, Naef A.A. & Al-Amoudi, Omar S. Baghabra & Al-Osta, Mohammed A., 2020. "Experimental and numerical investigation on innovative masonry walls for industrial and residential buildings," Applied Energy, Elsevier, vol. 276(C).
    11. Jadwiga Świrska-Perkowska & Zbigniew Perkowski, 2021. "Selection of Parameters for Accumulating Layer of Solar Walls with Transparent Insulation," Energies, MDPI, vol. 14(5), pages 1-55, February.
    12. Islam, Nazrul & Irshad, Kashif & Zahir, Md Hasan & Islam, Saiful, 2021. "Numerical and experimental study on the performance of a Photovoltaic Trombe wall system with Venetian blinds," Energy, Elsevier, vol. 218(C).
    13. Sánchez, M.N. & Giancola, E. & Suárez, M.J. & Blanco, E. & Heras, M.R., 2017. "Experimental evaluation of the airflow behaviour in horizontal and vertical Open Joint Ventilated Facades using Stereo-PIV," Renewable Energy, Elsevier, vol. 109(C), pages 613-623.
    14. Liang, Ruobing & Wang, Peng & Zhou, Chao & Pan, Qiangguang & Riaz, Ahmad & Zhang, Jili, 2020. "Thermal performance study of an active solar building façade with specific PV/T hybrid modules," Energy, Elsevier, vol. 191(C).
    15. Dwinanto Sukamto & Monica Siroux & Francois Gloriant, 2021. "Hot Box Investigations of a Ventilated Bioclimatic Wall for NZEB Building Façade," Energies, MDPI, vol. 14(5), pages 1-16, March.
    16. Krarti, Moncef, 2021. "Performance of PV integrated dynamic overhangs applied to US homes," Energy, Elsevier, vol. 230(C).
    17. Lin, Yuan & Ji, Jie & Lu, Xiangyou & Luo, Kun & Zhou, Fan & Ma, Yang, 2019. "Thermal and electrical behavior of built-middle photovoltaic integrated Trombe wall: Experimental and numerical study," Energy, Elsevier, vol. 189(C).
    18. Zhang, Chong & Gang, Wenjie & Xu, Xinhua & Li, Liao & Wang, Jinbo, 2019. "Modelling, experimental test, and design of an active air permeable wall by utilizing the low-grade exhaust air," Applied Energy, Elsevier, vol. 240(C), pages 730-743.
    19. Wang, Dengjia & Hu, Liang & Du, Hu & Liu, Yanfeng & Huang, Jianxiang & Xu, Yanchao & Liu, Jiaping, 2020. "Classification, experimental assessment, modeling methods and evaluation metrics of Trombe walls," Renewable and Sustainable Energy Reviews, Elsevier, vol. 124(C).
    20. Yu, Bendong & He, Wei & Li, Niansi & Wang, Liping & Cai, Jingyong & Chen, Hongbing & Ji, Jie & Xu, Gang, 2017. "Experimental and numerical performance analysis of a TC-Trombe wall," Applied Energy, Elsevier, vol. 206(C), pages 70-82.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2019:i:1:p:146-:d:302611. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.