IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v12y2019i18p3503-d266353.html
   My bibliography  Save this article

Cooling Performance Enhancement of Air-Cooled Condensers by Guiding Air Flow

Author

Listed:
  • Xianwei Huang

    (Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
    School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China)

  • Lin Chen

    (Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
    School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China)

  • Lijun Yang

    (Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
    School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China)

  • Xiaoze Du

    (Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
    School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China)

  • Yongping Yang

    (Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
    School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China)

Abstract

Adverse wind effects on the thermo-flow performances of air-cooled condensers (ACCs) can be effectively restrained by wind-proof devices, such as air deflectors. Based on a 2 × 300 MW coal-fired power generation unit, two types (plane and arc) of air deflectors were installed beneath the peripheral fans to improve the ACC’s cooling performance. With and without air deflectors, the air velocity, temperature, and pressure fields near the ACCs were simulated and analyzed in various windy conditions. The total air mass flow rate and unit back pressure were calculated and compared. The results show that, with the guidance of deflectors, reverse flows are obviously suppressed in the upwind condenser cells under windy conditions, which is conducive to an increased mass flow rate and heat dissipation and, subsequently, introduces a favorable thermo-flow performance of the cooling system. When the wind speed increases, the leading flow effect of the air deflectors improves, and improvements in the ACC’s performance in the wind directions of 45° and −45° are more satisfactory. However, hot plume recirculation may impede performance when the wind direction is 0°. For all cases, air deflectors in an arc shape are recommended to restrain the disadvantageous wind effects.

Suggested Citation

  • Xianwei Huang & Lin Chen & Lijun Yang & Xiaoze Du & Yongping Yang, 2019. "Cooling Performance Enhancement of Air-Cooled Condensers by Guiding Air Flow," Energies, MDPI, vol. 12(18), pages 1-28, September.
  • Handle: RePEc:gam:jeners:v:12:y:2019:i:18:p:3503-:d:266353
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/12/18/3503/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/12/18/3503/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Chen, Lei & Yang, Lijun & Du, Xiaoze & Yang, Yongping, 2016. "A novel layout of air-cooled condensers to improve thermo-flow performances," Applied Energy, Elsevier, vol. 165(C), pages 244-259.
    2. Butler, C. & Grimes, R., 2014. "The effect of wind on the optimal design and performance of a modular air-cooled condenser for a concentrated solar power plant," Energy, Elsevier, vol. 68(C), pages 886-895.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. O’Donovan, Alan & Grimes, Ronan & Sikora, Paul, 2019. "Enhanced performance of air-cooled thermal power plants using low temperature thermal storage," Applied Energy, Elsevier, vol. 250(C), pages 1673-1685.
    2. Li, Xiaoen & Wang, Ningling & Wang, Ligang & Yang, Yongping & Maréchal, François, 2018. "Identification of optimal operating strategy of direct air-cooling condenser for Rankine cycle based power plants," Applied Energy, Elsevier, vol. 209(C), pages 153-166.
    3. Zhang, Yi & Liu, Jinfeng & Yang, Tingting & Liu, Jianbang & Shen, Jiong & Fang, Fang, 2021. "Dynamic modeling and control of direct air-cooling condenser pressure considering couplings with adjacent systems," Energy, Elsevier, vol. 236(C).
    4. Najafi, Gholamhassan & Ghobadian, Barat & Yusaf, Talal & Safieddin Ardebili, Seyed Mohammad & Mamat, Rizalman, 2015. "Optimization of performance and exhaust emission parameters of a SI (spark ignition) engine with gasoline–ethanol blended fuels using response surface methodology," Energy, Elsevier, vol. 90(P2), pages 1815-1829.
    5. Li, Xiaoxiao & Gurgenci, Hal & Guan, Zhiqiang & Wang, Xurong & Duniam, Sam, 2017. "Measurements of crosswind influence on a natural draft dry cooling tower for a solar thermal power plant," Applied Energy, Elsevier, vol. 206(C), pages 1169-1183.
    6. Chen, Lei & Yang, Lijun & Du, Xiaoze & Yang, Yongping, 2016. "A novel layout of air-cooled condensers to improve thermo-flow performances," Applied Energy, Elsevier, vol. 165(C), pages 244-259.
    7. Weijia Wang & Lei Chen & Xianwei Huang & Lijun Yang & Xiaoze Du, 2017. "Performance Recovery of Natural Draft Dry Cooling Systems by Combined Air Leading Strategies," Energies, MDPI, vol. 10(12), pages 1-18, December.
    8. Wenhui Huang & Lei Chen & Weijia Wang & Lijun Yang & Xiaoze Du, 2020. "Cooling Performance Optimization of Direct Dry Cooling System Based on Partition Adjustment of Axial Flow Fans," Energies, MDPI, vol. 13(12), pages 1-22, June.
    9. Wenhui Huang & Lei Chen & Lijun Yang & Xiaoze Du, 2021. "Energy-Saving Strategies of Axial Flow Fans for Direct Dry Cooling System," Energies, MDPI, vol. 14(11), pages 1-25, May.
    10. Yang, Tingting & Wang, Wei & Zeng, Deliang & Liu, Jizhen & Cui, Can, 2017. "Closed-loop optimization control on fan speed of air-cooled steam condenser units for energy saving and rapid load regulation," Energy, Elsevier, vol. 135(C), pages 394-404.
    11. Luceño, José A. & Martín, Mariano, 2018. "Two-step optimization procedure for the conceptual design of A-frame systems for solar power plants," Energy, Elsevier, vol. 165(PB), pages 483-500.
    12. Lorenzo Tieghi & Giovanni Delibra & Johan Van der Spuy & Alessandro Corsini, 2024. "Design of Sinusoidal Leading Edge for Low-Speed Axial Fans Operating under Inflow Distortion," Energies, MDPI, vol. 17(5), pages 1-17, February.
    13. Tarun Kumar Aseri & Chandan Sharma & Tara C. Kandpal, 2022. "Condenser cooling technologies for concentrating solar power plants: a review," Environment, Development and Sustainability: A Multidisciplinary Approach to the Theory and Practice of Sustainable Development, Springer, vol. 24(4), pages 4511-4565, April.
    14. Wei Yuan & Fengzhong Sun & Yuanbin Zhao & Xuehong Chen & Ying Li & Xiaolei Lyu, 2020. "Numerical Study on the Influence Mechanism of Crosswind on Frozen Phenomena in a Direct Air-Cooled System," Energies, MDPI, vol. 13(15), pages 1-18, July.
    15. Yonghong Guo & Huimin Wei & Xiaoru Yang & Weijia Wang & Xiaoze Du & Lijun Yang, 2018. "Impacts of Water Flow Rate on Freezing Prevention of Air-Cooled Heat Exchangers in Power Plants," Energies, MDPI, vol. 11(1), pages 1-15, January.
    16. Weiming Ni & Zhihua Ge & Lijun Yang & Xiaoze Du, 2019. "Piping-Main Scheme for Condensers against the Adverse Impact of Environmental Conditions on Air-Cooled Thermal Power Units," Energies, MDPI, vol. 13(1), pages 1-17, December.
    17. Wang, Weiliang & Zhang, Hai & Li, Zheng & Lv, Junfu & Ni, Weidou & Li, Yongsheng, 2016. "Adoption of enclosure and windbreaks to prevent the degradation of the cooling performance for a natural draft dry cooling tower under crosswind conditions," Energy, Elsevier, vol. 116(P2), pages 1360-1369.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:12:y:2019:i:18:p:3503-:d:266353. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.