IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v30y2005i5p753-761.html
   My bibliography  Save this article

A new method for preventing HP from frosting

Author

Listed:
  • Wang, S.W.
  • Liu, Z.Y.

Abstract

The utility of HP (heat pump) in winter is limited by the problem of frost. The authors discuss a method for preventing HP from frosting, i.e. air is dehumidified by solid adsorbent before entering the evaporator. Not only does air humidity reduce, but also air temperature rises for absorbing adsorbing heat. As a result, the frost problem is resolved, and performance of the HP is improved in winter. The adsorbent bed can be fixed behind the outdoor unit of HP. It is made of zeolite plates, with an active carbon coat. Both sides of each zeolite plate are coated with a very thin layer of a mixture of active carbon and sodium silicate. The active carbon coat (black adsorbent material) can absorb sunlight as a supplementary source of energy for electrical heater for desorption, thus saving electrical energy. Air pressure loss through the bed is so low that the HP fan need not be changed. Using a mathematical model simulation for the sorption process, the method is proven to be valid.

Suggested Citation

  • Wang, S.W. & Liu, Z.Y., 2005. "A new method for preventing HP from frosting," Renewable Energy, Elsevier, vol. 30(5), pages 753-761.
  • Handle: RePEc:eee:renene:v:30:y:2005:i:5:p:753-761
    DOI: 10.1016/j.renene.2003.07.001
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148103002751
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2003.07.001?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Sheng, Wei & Liu, Pengpeng & Dang, Chaobin & Liu, Guixin, 2017. "Review of restraint frost method on cold surface," Renewable and Sustainable Energy Reviews, Elsevier, vol. 79(C), pages 806-813.
    2. Liu, Di & Zhao, Fu-Yun & Tang, Guang-Fa, 2007. "Frosting of heat pump with heat recovery facility," Renewable Energy, Elsevier, vol. 32(7), pages 1228-1242.
    3. Badri, Deyae & Toublanc, Cyril & Rouaud, Olivier & Havet, Michel, 2021. "Review on frosting, defrosting and frost management techniques in industrial food freezers," Renewable and Sustainable Energy Reviews, Elsevier, vol. 151(C).
    4. Wang, Fenghao & Wang, Zhihua & Zheng, Yuxin & Lin, Zhang & Hao, Pengfei & Huan, Chao & Wang, Tian, 2015. "Performance investigation of a novel frost-free air-source heat pump water heater combined with energy storage and dehumidification," Applied Energy, Elsevier, vol. 139(C), pages 212-219.
    5. Wang, Feng & Liang, Caihua & Zhang, Xiaosong, 2018. "Research of anti-frosting technology in refrigeration and air conditioning fields: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 81(P1), pages 707-722.
    6. She, Xiaohui & Cong, Lin & Nie, Binjian & Leng, Guanghui & Peng, Hao & Chen, Yi & Zhang, Xiaosong & Wen, Tao & Yang, Hongxing & Luo, Yimo, 2018. "Energy-efficient and -economic technologies for air conditioning with vapor compression refrigeration: A comprehensive review," Applied Energy, Elsevier, vol. 232(C), pages 157-186.
    7. Amer, Mohammed & Wang, Chi-Chuan, 2017. "Review of defrosting methods," Renewable and Sustainable Energy Reviews, Elsevier, vol. 73(C), pages 53-74.
    8. Yi Zhang & Guanmin Zhang & Aiqun Zhang & Yinhan Jin & Ruirui Ru & Maocheng Tian, 2018. "Frosting Phenomenon and Frost-Free Technology of Outdoor Air Heat Exchanger for an Air-Source Heat Pump System in China: An Analysis and Review," Energies, MDPI, vol. 11(10), pages 1-36, October.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:30:y:2005:i:5:p:753-761. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.