Operational characteristics and controlling strategies of a novel dual-return-air dehumidification evaporative cooling system (DDEC)

Author

Listed:
  • Chun, Liang
  • Liao, Zicheng
  • Wang, Guoqiang
  • Xiao, Yao
  • Huo, Jinpeng
  • Liu, Dong
  • Jiang, Bin

Abstract

Dehumidification evaporative cooling (DEC) systems exhibit superior environmental adaptability compared to conventional evaporative cooling systems. However, the dehumidification process in DEC is coupled with its cooling process, presenting challenges in adapting to varying environmental conditions. To address this issue, this study proposes a novel dual-return-air dehumidification evaporative cooling system (DDEC) that utilizes two return airflows to control both dehumidification and cooling efficiency. A thermodynamic model based on COMSOL LiveLink with MATLAB for the DDEC has been established and validated, enabling an analysis of the impact of operational parameters on its performance and the identification of key parameters. The results show that there are an optimum inlet flow rate (1100 m3/h) and a third flow rate control factor (0.2) that maximize the coefficient of performance (COP), giving the maximum COP of 0.87 and 0.35 respectively. Moreover, the first and second air flow rate control factors only have a significant influence on the supply air humidity of the DDEC. A higher regenerative temperature can reduce both the temperature and humidity ratio of the supply air but tends to decrease COP. Finally, a single-directional controlling strategy is proposed and analyzed for the DDEC application in different environments.

Suggested Citation

  • Chun, Liang & Liao, Zicheng & Wang, Guoqiang & Xiao, Yao & Huo, Jinpeng & Liu, Dong & Jiang, Bin, 2024. "Operational characteristics and controlling strategies of a novel dual-return-air dehumidification evaporative cooling system (DDEC)," Energy, Elsevier, vol. 309(C).
  • Handle: RePEc:eee:energy:v:309:y:2024:i:c:s0360544224029487
    DOI: 10.1016/j.energy.2024.133173
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544224029487
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2024.133173?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to

    for a different version of it.

    References listed on IDEAS

    as
    1. Han, Zongwei & Xue, Da & Wei, Haotian & Ji, Qiang & Sun, Xiaoqing & Li, Xiuming, 2021. "Study on operation strategy of evaporative cooling composite air conditioning system in data center," Renewable Energy, Elsevier, vol. 177(C), pages 1147-1160.
    2. Liu, Shuo & Jang, Hyusan & Yeo, Myoung-Souk, 2023. "Experimental study on the operating characteristic of the desiccant cooling systems with the potential of condensing heat recovery," Energy, Elsevier, vol. 283(C).
    3. Ge, T.S. & Dai, Y.J. & Wang, R.Z., 2014. "Review on solar powered rotary desiccant wheel cooling system," Renewable and Sustainable Energy Reviews, Elsevier, vol. 39(C), pages 476-497.
    4. Mujahid Rafique, M. & Gandhidasan, P. & Rehman, Shafiqur & Al-Hadhrami, Luai M., 2015. "A review on desiccant based evaporative cooling systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 45(C), pages 145-159.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Li, Tailu & Yu, Haifang & Qi, Jing & Yuan, Ye, 2026. "Dynamic thermal loss of ice tank of seasonal ice storage for air conditioning," Renewable Energy, Elsevier, vol. 256(PA).

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Speerforck, Arne & Schmitz, Gerhard, 2016. "Experimental investigation of a ground-coupled desiccant assisted air conditioning system," Applied Energy, Elsevier, vol. 181(C), pages 575-585.
    2. Chen, Chih-Hao & Hsu, Chien-Yeh & Chen, Chih-Chieh & Chiang, Yuan-Ching & Chen, Sih-Li, 2016. "Silica gel/polymer composite desiccant wheel combined with heat pump for air-conditioning systems," Energy, Elsevier, vol. 94(C), pages 87-99.
    3. James Kamau & Baye Alioune Ndiogou & Nassif Rayess, 2025. "Simulation-Based Performance Evaluation of a Desiccant Indirect Evaporative Cooling System for Office Buildings in Hot–Humid East African Coastal Climates," Sustainability, MDPI, vol. 17(17), pages 1-28, August.
    4. Zu, Kan & Qin, Menghao & Cui, Shuqing, 2020. "Progress and potential of metal-organic frameworks (MOFs) as novel desiccants for built environment control: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 133(C).
    5. Fekadu, Geleta & Subudhi, Sudhakar, 2018. "Renewable energy for liquid desiccants air conditioning system: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 93(C), pages 364-379.
    6. Anatolijs Borodinecs & Kristina Lebedeva & Natalja Sidenko & Aleksejs Prozuments, 2022. "Enhancement of Chiller Performance by Water Distribution on the Adiabatic Cooling Pad’s Mesh Surface," Clean Technol., MDPI, vol. 4(3), pages 1-19, July.
    7. Liu, Shuo & Xue, Zhifeng & Zhang, Yongjie & Zhang, Tao & Liu, Xiaohua & Wang, Chaoliang & Liu, Wei, 2026. "Improving photovoltaic self-consumption and building power generation-consumption matching via indoor humidity flexible control," Renewable Energy, Elsevier, vol. 258(C).
    8. Han, Ouzhu & Ding, Tao & Zhang, Xiaosheng & Mu, Chenggang & He, Xinran & Zhang, Hongji & Jia, Wenhao & Ma, Zhoujun, 2023. "A shared energy storage business model for data center clusters considering renewable energy uncertainties," Renewable Energy, Elsevier, vol. 202(C), pages 1273-1290.
    9. Zhang, Ce & Hou, Beiran & Li, Minxia & Dang, Chaobin & Chen, Xun & Li, Xiuming & Han, Zongwei, 2025. "Feasibility analysis of multi-mode data center liquid cooling system integrated with Carnot battery energy storage module," Energy, Elsevier, vol. 320(C).
    10. Zhu, Haitao & Lin, Botao, 2024. "Digital twin-driven energy consumption management of integrated heat pipe cooling system for a data center," Applied Energy, Elsevier, vol. 373(C).
    11. Shamim, Jubair A. & Hsu, Wei-Lun & Paul, Soumyadeep & Yu, Lili & Daiguji, Hirofumi, 2021. "A review of solid desiccant dehumidifiers: Current status and near-term development goals in the context of net zero energy buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 137(C).
    12. Sun, Xiaoqing & Zhang, Ce & Han, Zongwei & Dong, Jiaxiang & Zhang, Yiqi & Li, Mengyi & Li, Xiuming & Wang, Qinghai & Wen, Zhenwu & Zheng, Baoli, 2023. "Experimental study on a novel pump-driven heat pipe/vapor compression system for rack-level cooling of data centers," Energy, Elsevier, vol. 274(C).
    13. Yang, Tianyu & Ge, Tianshu, 2024. "Performance study of a heat pump fresh air unit based on desiccant coated heat exchangers under different operation strategies," Energy, Elsevier, vol. 296(C).
    14. Peter Niemann & Finn Richter & Arne Speerforck & Gerhard Schmitz, 2019. "Desiccant-Assisted Air Conditioning System Relying on Solar and Geothermal Energy during Summer and Winter," Energies, MDPI, vol. 12(16), pages 1-20, August.
    15. Liu, Haoran & Huang, Yixiang & Tian, Shaochen & Huang, Lei & Li, Shangao & Wang, Qinbao & Su, Xing, 2025. "Operational performance of heat pump desiccant wheel system in low humidity industrial environment: On-site measurements and model based optimization," Energy, Elsevier, vol. 322(C).
    16. Jianke Hu & Kai Teng & Yida Qiu & Yuzhu Chen & Jun Wang & Peter Lund, 2022. "Thermodynamic and Economic Performance Assessment of Double-Effect Absorption Chiller Systems with Series and Parallel Connections," Energies, MDPI, vol. 15(23), pages 1-17, December.
    17. Lu, Gui & Liu, Yan & Jiang, Can & Yang, Zi-Jing & Meng, Jing-Hui, 2025. "A deep agent reinforcement learning-based early adaptive multivariate state estimation fault diagnosis method for multi-mode cooling system in data center," Energy, Elsevier, vol. 334(C).
    18. Zhang, Xueping & Li, Gui & Han, Zongwei & Yang, Ziwei & Bi, Weiqiang & Li, Xiuming & Yang, Lingyan, 2023. "Study on the influence of buried pipe fault on the operation of ground source heat pump system," Renewable Energy, Elsevier, vol. 210(C), pages 12-25.
    19. Singh, Ashutosh & Kumar, Sunil & Dev, Rahul, 2019. "Studies on cocopeat, sawdust and dried cow dung as desiccant for evaporative cooling system," Renewable Energy, Elsevier, vol. 142(C), pages 295-303.
    20. Ji, Qiang & Li, Yizhen & Yin, Yonggao & Che, Chunwen & Huang, Gongsheng, 2026. "Compression-absorption hybrid heat pumps operating wide temperature ranges: A review and perspectives for large temperature lift," Applied Energy, Elsevier, vol. 405(C).

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:309:y:2024:i:c:s0360544224029487. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.