IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v17y2024i4p776-d1334381.html
   My bibliography  Save this article

The Effects of Exterior Glazing on Human Thermal Comfort in Office Buildings

Author

Listed:
  • Bing Song

    (College of Architecture, Xi’an University of Architecture and Technology, Xi’an 710055, China
    State Key Laboratory of Green Building, Xi’an University of Architecture and Technology, Xi’an 710055, China)

  • Lujian Bai

    (College of Architecture and Civil Engineering, Xi’an University of Science and Technology, Xi’an 710054, China)

  • Liu Yang

    (College of Architecture, Xi’an University of Architecture and Technology, Xi’an 710055, China
    State Key Laboratory of Green Building, Xi’an University of Architecture and Technology, Xi’an 710055, China)

Abstract

As a major component of the building envelope, the energy-saving design of exterior windows is key to energy savings in office buildings. The conventional design of exterior windows mainly focused on their impact on heating and cooling energy but ignored the indoor thermal comfort problems caused by the direct solar radiation transmitted by windows and the fluctuation of their internal surface temperatures. This study analyzed the influence of exterior windows on the indoor thermal environment of office buildings by carrying out field experiments. The experiments were carried out in a typical office building in Xi’an during December and January. The impact of exterior windows on human thermal comfort was studied from two perspectives: longwave radiation from the surface of window glass and solar shortwave radiation. It was found that solar radiation was the main cause of temperature fluctuations on the internal surface of windows and created non-uniform thermal environments. The mean radiant temperature fluctuations in the near-window area could reach up to 7.8 °C due to outdoor solar radiation in winter. Solar radiation transmitted by windows directly affects thermal sensations. Since conventional thermal comfort models or indices underestimated the thermal sensations of occupants in the presence of solar radiation, the additional thermal loads caused by solar radiation needed to be taken into account. The allowable operative temperature range for maintaining thermal comfort should be reduced by 0.5 °C when occupants are exposed to solar radiation.

Suggested Citation

  • Bing Song & Lujian Bai & Liu Yang, 2024. "The Effects of Exterior Glazing on Human Thermal Comfort in Office Buildings," Energies, MDPI, vol. 17(4), pages 1-16, February.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:4:p:776-:d:1334381
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/4/776/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/4/776/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Cuce, Erdem & Riffat, Saffa B., 2015. "A state-of-the-art review on innovative glazing technologies," Renewable and Sustainable Energy Reviews, Elsevier, vol. 41(C), pages 695-714.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Cristina Cornaro & Ludovica Renzi & Marco Pierro & Aldo Di Carlo & Alessandro Guglielmotti, 2018. "Thermal and Electrical Characterization of a Semi-Transparent Dye-Sensitized Photovoltaic Module under Real Operating Conditions," Energies, MDPI, vol. 11(1), pages 1-16, January.
    2. Michaux, Ghislain & Greffet, Rémy & Salagnac, Patrick & Ridoret, Jean-Baptiste, 2019. "Modelling of an airflow window and numerical investigation of its thermal performances by comparison to conventional double and triple-glazed windows," Applied Energy, Elsevier, vol. 242(C), pages 27-45.
    3. Sara Brito-Coimbra & Daniel Aelenei & Maria Gloria Gomes & Antonio Moret Rodrigues, 2021. "Building Façade Retrofit with Solar Passive Technologies: A Literature Review," Energies, MDPI, vol. 14(6), pages 1-18, March.
    4. Ruth M. Saint & Céline Garnier & Francesco Pomponi & John Currie, 2018. "Thermal Performance through Heat Retention in Integrated Collector-Storage Solar Water Heaters: A Review," Energies, MDPI, vol. 11(6), pages 1-26, June.
    5. Cuce, Erdem, 2016. "Toward multi-functional PV glazing technologies in low/zero carbon buildings: Heat insulation solar glass – Latest developments and future prospects," Renewable and Sustainable Energy Reviews, Elsevier, vol. 60(C), pages 1286-1301.
    6. Shiva Amirkhani & Ali Bahadori-Jahromi & Anastasia Mylona & Paulina Godfrey & Darren Cook, 2019. "Impact of Low-E Window Films on Energy Consumption and CO 2 Emissions of an Existing UK Hotel Building," Sustainability, MDPI, vol. 11(16), pages 1-24, August.
    7. Marchini, F. & Chiatti, C. & Fabiani, C. & Pisello, A.L., 2023. "Development of an innovative translucent–photoluminescent coating for smart windows applications: An experimental and numerical investigation," Renewable and Sustainable Energy Reviews, Elsevier, vol. 184(C).
    8. Ramkishore Singh & Dharam Buddhi & Samar Thapa & Chander Prakash & Rajesh Singh & Atul Sharma & Shane Sheoran & Kuldeep Kumar Saxena, 2022. "Sensitivity Analysis for Decisive Design Parameters for Energy and Indoor Visual Performances of a Glazed Façade Office Building," Sustainability, MDPI, vol. 14(21), pages 1-27, October.
    9. Cuce, Erdem & Cuce, Pinar Mert & Young, Chin-Huai, 2016. "Energy saving potential of heat insulation solar glass: Key results from laboratory and in-situ testing," Energy, Elsevier, vol. 97(C), pages 369-380.
    10. Miranda, Nicole D. & Renaldi, Renaldi & Khosla, Radhika & McCulloch, Malcolm D., 2021. "Bibliometric analysis and landscape of actors in passive cooling research," Renewable and Sustainable Energy Reviews, Elsevier, vol. 149(C).
    11. Garlisi, Corrado & Trepci, Esra & Li, Xuan & Al Sakkaf, Reem & Al-Ali, Khalid & Nogueira, Ricardo Pereira & Zheng, Lianxi & Azar, Elie & Palmisano, Giovanni, 2020. "Multilayer thin film structures for multifunctional glass: Self-cleaning, antireflective and energy-saving properties," Applied Energy, Elsevier, vol. 264(C).
    12. Huang, Junchao & Chen, Xi & Peng, Jinqing & Yang, Hongxing, 2021. "Modelling analyses of the thermal property and heat transfer performance of a novel compositive PV vacuum glazing," Renewable Energy, Elsevier, vol. 163(C), pages 1238-1252.
    13. Tettey, Uniben Yao Ayikoe & Dodoo, Ambrose & Gustavsson, Leif, 2017. "Energy use implications of different design strategies for multi-storey residential buildings under future climates," Energy, Elsevier, vol. 138(C), pages 846-860.
    14. Ali Bahadori-Jahromi & Abdulazeez Rotimi & Anastasia Mylona & Paulina Godfrey & Darren Cook, 2017. "Impact of Window Films on the Overall Energy Consumption of Existing UK Hotel Buildings," Sustainability, MDPI, vol. 9(5), pages 1-23, May.
    15. Lyu, Yuan-Li & Liu, Wen-Jie & Su, Hua & Wu, Xuan, 2019. "Numerical analysis on the advantages of evacuated gap insulation of vacuum-water flow window in building energy saving under various climates," Energy, Elsevier, vol. 175(C), pages 353-364.
    16. Paola Marrone & Francesco Asdrubali & Daniela Venanzi & Federico Orsini & Luca Evangelisti & Claudia Guattari & Roberto De Lieto Vollaro & Lucia Fontana & Gianluca Grazieschi & Paolo Matteucci & Marta, 2021. "On the Retrofit of Existing Buildings with Aerogel Panels: Energy, Environmental and Economic Issues," Energies, MDPI, vol. 14(5), pages 1-22, February.
    17. Pacheco-Torgal, F., 2017. "High tech startup creation for energy efficient built environment," Renewable and Sustainable Energy Reviews, Elsevier, vol. 71(C), pages 618-629.
    18. Liu, Changyu & Sun, Yongxiang & Li, Dong & Bian, Ji & Wu, Yangyang & Li, Pengfei & Sun, Yong, 2022. "Influence of enclosure filled with phase change material on photo-thermal regulation of direct absorption anaerobic reactor: Numerical and experimental study," Applied Energy, Elsevier, vol. 313(C).
    19. Liu, Changyu & Wu, Yangyang & Bian, Ji & Li, Dong & Liu, Xiaoyan, 2018. "Influence of PCM design parameters on thermal and optical performance of multi-layer glazed roof," Applied Energy, Elsevier, vol. 212(C), pages 151-161.
    20. Wang, Y. & Mauree, D. & Sun, Q. & Lin, H. & Scartezzini, J.L. & Wennersten, R., 2020. "A review of approaches to low-carbon transition of high-rise residential buildings in China," Renewable and Sustainable Energy Reviews, Elsevier, vol. 131(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:4:p:776-:d:1334381. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.