IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v17y2025i17p7805-d1737718.html
   My bibliography  Save this article

Sustainable Indoor Thermal Regulation with Hybrid Desiccant and Post-Cooling Technologies

Author

Listed:
  • Lolaksha Shettigar

    (Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India)

  • Nitesh Kumar

    (Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India)

  • Madhwesh Nagaraj

    (Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India)

  • Mandya Channegowda Gowrishankar

    (Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India)

  • Shiva Kumar

    (Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India)

  • Sampath Suranjan Salins

    (Department of Mechanical Engineering, School of Engineering and Information Technology, Manipal Academy of Higher Education, Dubai 345050, United Arab Emirates)

Abstract

This study investigated the performance of a hybrid desiccant dehumidification system integrated with a post-cooling mechanism, focusing on its application to energy-efficient indoor climate control. A liquid desiccant system using magnesium chloride (MgCl 2 ) was tested in its pure form and in combination with silica gel at 10% and 20% concentrations to enhance its moisture removal capabilities. The key parameters, including the air velocity (3–6 m/s), desiccant flow rate (1–3 LPM), and desiccant composition, were varied to analyze their effects on the dehumidification efficiency, moisture removal rate (MRR), temperature reduction after post-cooling, and coefficient of performance (COP). The results show that post-cooling using a crossflow heat exchanger effectively lowered the exit air temperature, ensuring thermal comfort. Addition of silica gel significantly improved system performance. The MgCl 2 + 20% silica gel mixture achieved the highest dehumidification efficiency of 0.86, the greatest temperature drop of 1.95 °C, and the maximum COP of 2.36 at optimal flow conditions. While the dehumidification efficiency declined with increasing air velocity due to reduced contact time, the COP increased owing to the higher thermal processing of the air stream. This study highlights the potential of optimized hybrid desiccant systems as sustainable solutions for building air conditioning, aligning with the key Sustainable Development Goals (SDGs) related to clean energy, climate action, and sustainable infrastructure.

Suggested Citation

  • Lolaksha Shettigar & Nitesh Kumar & Madhwesh Nagaraj & Mandya Channegowda Gowrishankar & Shiva Kumar & Sampath Suranjan Salins, 2025. "Sustainable Indoor Thermal Regulation with Hybrid Desiccant and Post-Cooling Technologies," Sustainability, MDPI, vol. 17(17), pages 1-17, August.
  • Handle: RePEc:gam:jsusta:v:17:y:2025:i:17:p:7805-:d:1737718
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/17/17/7805/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/17/17/7805/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:17:y:2025:i:17:p:7805-:d:1737718. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.