Modelling of Refrigerant Distribution in an Oil-Free Refrigeration System using R134a

Author

Listed:
  • Xinwen Chen

    (Department of Mechanical Engineering, Yangzhou University, Yangzhou 225012, China)

  • Zhaohua Li

    (Department of Engineering and Design, University of Sussex, Falmer, Brighton BN1 9QT, UK)

  • Yi Zhao

    (École Polytechnique, 91128 Palaiseau, France)

  • Hanying Jiang

    (Department of Engineering and Design, University of Sussex, Falmer, Brighton BN1 9QT, UK)

  • Kun Liang

    (Department of Mechanical Engineering, Yangzhou University, Yangzhou 225012, China
    Department of Engineering and Design, University of Sussex, Falmer, Brighton BN1 9QT, UK)

  • Jingxin Chen

    (Department of Mechanical Engineering, Yangzhou University, Yangzhou 225012, China)

Abstract

Increasing number of refrigeration units has led to an increase of CO 2 emissions and the destruction of the ozone layer. Using low global warming potential (GWP) refrigerants, improving the efficiency of vapour compression refrigeration (VCR) units, and minimising refrigerant leakages can reduce the global warming effect. Investigating the refrigerant distribution under varied operating conditions can provide a deeper understanding of refrigerant charge optimization. This study proposed a model of refrigerant mass distribution in a prototype oil-free VCR system using a linear compressor with variable strokes and R134a. The absence of the oil lubricant allows the adoption of compact heat exchangers, such as micro-channels, so that the total refrigerant charge can be reduced significantly. The predicted total refrigerant charge has a Mean Absolute Percentage Error (MAPE) of 3.7%. The simulation results indicate that refrigerant distributed in the condenser is most sensitive to operating conditions and total refrigerant charges. The refrigerant accumulated in the condenser is 6.8% higher at a total refrigerant charge of 0.33 kg than that of 0.22 kg. For a total refrigerant charge of 0.33 kg, 72.1% of the total refrigerant can accumulate in the condenser. At a fixed pressure ratio, the refrigerant as a two-phase form in the condenser decreases slightly with the increase of compressor strokes, resulting in a larger mass flow rate, thus cooling capacity. The present model can be adapted for optimization of a refrigeration unit and its components.

Suggested Citation

  • Xinwen Chen & Zhaohua Li & Yi Zhao & Hanying Jiang & Kun Liang & Jingxin Chen, 2019. "Modelling of Refrigerant Distribution in an Oil-Free Refrigeration System using R134a," Energies, MDPI, vol. 12(24), pages 1-15, December.
  • Handle: RePEc:gam:jeners:v:12:y:2019:i:24:p:4792-:d:298512
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/12/24/4792/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/12/24/4792/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Bolaji, B.O., 2010. "Experimental study of R152a and R32 to replace R134a in a domestic refrigerator," Energy, Elsevier, vol. 35(9), pages 3793-3798.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Zhe Wang & Fenghui Han & Yulong Ji & Wenhua Li, 2020. "Performance and Exergy Transfer Analysis of Heat Exchangers with Graphene Nanofluids in Seawater Source Marine Heat Pump System," Energies, MDPI, vol. 13(7), pages 1-17, April.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Yijian He & Yufu Zheng & Jianguang Zhao & Qifei Chen & Lunyuan Zhang, 2024. "Study of a Novel Hybrid Refrigeration System, with Natural Refrigerants and Ultra-Low Carbon Emissions, for Air Conditioning," Energies, MDPI, vol. 17(4), pages 1-19, February.
    2. Kutub Uddin & Bidyut Baran Saha, 2022. "An Overview of Environment-Friendly Refrigerants for Domestic Air Conditioning Applications," Energies, MDPI, vol. 15(21), pages 1-24, October.
    3. Jeon, Yongseok & Kim, Dongwoo & Jung, Jongho & Jang, Dong Soo & Kim, Yongchan, 2018. "Comparative performance evaluation of conventional and condenser outlet split ejector-based domestic refrigerator-freezers using R600a," Energy, Elsevier, vol. 161(C), pages 1085-1095.
    4. Wang, Xiao & Yu, Jianlin, 2015. "An experimental investigation on a novel ejector enhanced refrigeration cycle applied in the domestic refrigerator-freezer," Energy, Elsevier, vol. 93(P1), pages 202-209.
    5. Meng, Xuelin & Zheng, Danxing & Wang, Jianzhao & Li, Xinru, 2013. "Energy saving mechanism analysis of the absorption–compression hybrid refrigeration cycle," Renewable Energy, Elsevier, vol. 57(C), pages 43-50.
    6. Li, Gang & Eisele, Magnus & Lee, Hoseong & Hwang, Yunho & Radermacher, Reinhard, 2014. "Experimental investigation of energy and exergy performance of secondary loop automotive air-conditioning systems using low-GWP (global warming potential) refrigerants," Energy, Elsevier, vol. 68(C), pages 819-831.
    7. Zilio, Claudio & Brown, J. Steven & Schiochet, Giovanni & Cavallini, Alberto, 2011. "The refrigerant R1234yf in air conditioning systems," Energy, Elsevier, vol. 36(10), pages 6110-6120.
    8. Liang, Kun & Stone, Richard & Davies, Gareth & Dadd, Mike & Bailey, Paul, 2014. "Modelling and measurement of a moving magnet linear compressor performance," Energy, Elsevier, vol. 66(C), pages 487-495.
    9. Yuan, Zhiyi & Ou, Xunmin & Peng, Tianduo & Yan, Xiaoyu, 2018. "Development and application of a life cycle greenhouse gas emission analysis model for mobile air conditioning systems," Applied Energy, Elsevier, vol. 221(C), pages 161-179.
    10. Aprea, C. & Greco, A. & Maiorino, A., 2012. "An experimental evaluation of the greenhouse effect in the substitution of R134a with CO2," Energy, Elsevier, vol. 45(1), pages 753-761.
    11. Yang, Mina & Jung, Chung Woo & Kang, Yong Tae, 2015. "Development of high efficiency cycles for domestic refrigerator-freezer application," Energy, Elsevier, vol. 93(P2), pages 2258-2266.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:12:y:2019:i:24:p:4792-:d:298512. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.