Author
Abstract
In an electric utility network, the occurrence of voltage depression on transmission and distribution lines is due to the flow of reactive power. It is desirable to regulate the voltage within a narrow range of its nominal value (±5% range around their nominal values). Thus, reactive power control is necessary so as to control dynamic voltage swings under various system conditions and thereby improve the power system transmission and distribution performance. A fast acting Static Compensator (STATCOM) is required to produce or absorb reactive power so as to provide the necessary reactive power balance in transmission and distribution system. Modern reactive power compensation employs voltage source inverter (VSI). In this paper, a static compensator based on three-phase, three-level voltage source inverter (VSI) was investigated. The paper is intended to show how this STATCOM can be used to improve the ac system power factor and voltage regulation, and hence improve the performance of the transmission and distribution lines. Application of this STATCOM to a transmission system achieved unity power factor, thereby reducing the active power loss by 38.7% and consequently decreasing power costs, as well as increasing transmission system capacity. The presence of the STATCOM also reduced the reactive power flowing on the line from 2.79 MVAr to 1745VAr - resulting in optimum voltage regulation at the load bus. The reactive elements (L and C) are small in size.
Suggested Citation
Aniagboso John Onah, 2018.
"A Three-Level Inverter Based Static Compensator (STATCOM),"
European Journal of Electrical Engineering and Computer Science, European Open Science, vol. 2(5), July.
Handle:
RePEc:epw:ejece0:v:2:y:2018:i:5:id:19028
DOI: 10.24018/ejece.2018.2.5.28
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:epw:ejece0:v:2:y:2018:i:5:id:19028. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: support (email available below). General contact details of provider: https://eu-opensci.org/index.php/ejece .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.