IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v159y2018icp724-736.html
   My bibliography  Save this article

Energy performance of a bedroom task/ambient air conditioning (TAC) system applied in different climate zones of China

Author

Listed:
  • Mao, Ning
  • Hao, Jingyu
  • Cui, Borui
  • Li, Yuxing
  • Song, Mengjie
  • Xu, Yingjie
  • Deng, Shiming

Abstract

Task/ambient air conditioning (TAC) system applied to bedrooms has been investigated and its energy efficient performance reported. To promote the application of bedroom TAC to a larger region, a numerical study was carried out on a bedroom TAC system applied in five different climate zones. To simplify the numerical study, response surface methodology (RSM) was used to predict operating power of TAC based on CFD results. It's found that the daily energy consumption in the typical day was from 0 kWh in Kunming to 1.27 kWh in Shanghai, the averaged daily energy consumption varied from 0.47 kWh in June to 0.56 kWh in August for Guangzhou, and the total energy consumption in summer ranged from 0 kWh in Kunming to 58.33 kWh in Guangzhou. Meanwhile, the operating time of the TAC were also different between these five cities. In order to save energy, different set points of toz (average air temperature in the occupied zone) were investigated. It's found that increasing the toz from 24 to 25 °C can reduce energy consumption by about 23.42% in Shanghai to 36.23% in Beijing. Besides, the energy saving potential using two operating modes were compared: variable air flow rate and variable air temperature.

Suggested Citation

  • Mao, Ning & Hao, Jingyu & Cui, Borui & Li, Yuxing & Song, Mengjie & Xu, Yingjie & Deng, Shiming, 2018. "Energy performance of a bedroom task/ambient air conditioning (TAC) system applied in different climate zones of China," Energy, Elsevier, vol. 159(C), pages 724-736.
  • Handle: RePEc:eee:energy:v:159:y:2018:i:c:p:724-736
    DOI: 10.1016/j.energy.2018.06.211
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544218312763
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2018.06.211?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Yang, Liu & Lam, Joseph C. & Tsang, C.L., 2008. "Energy performance of building envelopes in different climate zones in China," Applied Energy, Elsevier, vol. 85(9), pages 800-817, September.
    2. Song, Mengjie & Deng, Shiming & Mao, Ning & Ye, Xianming, 2016. "An experimental study on defrosting performance for an air source heat pump unit with a horizontally installed multi-circuit outdoor coil," Applied Energy, Elsevier, vol. 165(C), pages 371-382.
    3. Song, Mengjie & Gong, Guangcai & Mao, Ning & Deng, Shiming & Wang, Zhihua, 2017. "Experimental investigation on an air source heat pump unit with a three-circuit outdoor coil for its reverse cycle defrosting termination temperature," Applied Energy, Elsevier, vol. 204(C), pages 1388-1398.
    4. Song, Mengjie & Xia, Liang & Mao, Ning & Deng, Shiming, 2016. "An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil," Applied Energy, Elsevier, vol. 164(C), pages 36-44.
    5. Tong, Zheming & Chen, Yujiao & Malkawi, Ali, 2016. "Defining the Influence Region in neighborhood-scale CFD simulations for natural ventilation design," Applied Energy, Elsevier, vol. 182(C), pages 625-633.
    6. Huang, Yu & Niu, Jian-lei & Chung, Tse-ming, 2013. "Study on performance of energy-efficient retrofitting measures on commercial building external walls in cooling-dominant cities," Applied Energy, Elsevier, vol. 103(C), pages 97-108.
    7. Tso, Geoffrey K.F & Yau, Kelvin K.W, 2003. "A study of domestic energy usage patterns in Hong Kong," Energy, Elsevier, vol. 28(15), pages 1671-1682.
    8. Lei, Jiawei & Yang, Jinglei & Yang, En-Hua, 2016. "Energy performance of building envelopes integrated with phase change materials for cooling load reduction in tropical Singapore," Applied Energy, Elsevier, vol. 162(C), pages 207-217.
    9. Chen, Xi & Yang, Hongxing, 2018. "Integrated energy performance optimization of a passively designed high-rise residential building in different climatic zones of China," Applied Energy, Elsevier, vol. 215(C), pages 145-158.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Mao, Ning & Hao, Jingyu & He, Tianbiao & Song, Mengjie & Xu, Yingjie & Deng, Shiming, 2019. "PMV-based dynamic optimization of energy consumption for a residential task/ambient air conditioning system in different climate zones," Renewable Energy, Elsevier, vol. 142(C), pages 41-54.
    2. Chi, Fang'ai & Xu, Liming & Pan, Jiajie & Wang, Ruonan & Tao, Yekang & Guo, Yuang & Peng, Changhai, 2020. "Prediction of the total day-round thermal load for residential buildings at various scales based on weather forecast data," Applied Energy, Elsevier, vol. 280(C).
    3. Wang, Cheng & Guo, Xiaofeng & Zhu, Ye, 2019. "Energy saving with Optic-Variable Wall for stable air temperature control," Energy, Elsevier, vol. 173(C), pages 38-47.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Mao, Ning & Pan, Dongmei & Li, Zhao & Xu, Yingjie & Song, Mengjie & Deng, Shiming, 2017. "A numerical study on influences of building envelope heat gain on operating performances of a bed-based task/ambient air conditioning (TAC) system in energy saving and thermal comfort," Applied Energy, Elsevier, vol. 192(C), pages 213-221.
    2. Mao, Ning & Hao, Jingyu & He, Tianbiao & Song, Mengjie & Xu, Yingjie & Deng, Shiming, 2019. "PMV-based dynamic optimization of energy consumption for a residential task/ambient air conditioning system in different climate zones," Renewable Energy, Elsevier, vol. 142(C), pages 41-54.
    3. Liu, Zhijian & Liu, Yuanwei & He, Bao-Jie & Xu, Wei & Jin, Guangya & Zhang, Xutao, 2019. "Application and suitability analysis of the key technologies in nearly zero energy buildings in China," Renewable and Sustainable Energy Reviews, Elsevier, vol. 101(C), pages 329-345.
    4. Xu, Wei & Liu, Changping & Li, Angui & Li, Ji & Qiao, Biao, 2020. "Feasibility and performance study on hybrid air source heat pump system for ultra-low energy building in severe cold region of China," Renewable Energy, Elsevier, vol. 146(C), pages 2124-2133.
    5. Song, Mengjie & Deng, Shiming & Dang, Chaobin & Mao, Ning & Wang, Zhihua, 2018. "Review on improvement for air source heat pump units during frosting and defrosting," Applied Energy, Elsevier, vol. 211(C), pages 1150-1170.
    6. Yang, Bowen & Dong, Jiankai & Zhang, Long & Song, Mengjie & Jiang, Yiqiang & Deng, Shiming, 2019. "Heating and energy storage characteristics of multi-split air source heat pump based on energy storage defrosting," Applied Energy, Elsevier, vol. 238(C), pages 303-310.
    7. Song, Mengjie & Xu, Xiangguo & Mao, Ning & Deng, Shiming & Xu, Yingjie, 2017. "Energy transfer procession in an air source heat pump unit during defrosting," Applied Energy, Elsevier, vol. 204(C), pages 679-689.
    8. Hu, Wenju & Song, Mengjie & Jiang, Yiqiang & Yao, Yang & Gao, Yan, 2019. "A modeling study on the heat storage and release characteristics of a phase change material based double-spiral coiled heat exchanger in an air source heat pump for defrosting," Applied Energy, Elsevier, vol. 236(C), pages 877-892.
    9. Wang, Feng & Liang, Caihua & Zhang, Xiaosong, 2018. "Research of anti-frosting technology in refrigeration and air conditioning fields: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 81(P1), pages 707-722.
    10. Xiong, Yongqing & Yang, Xiaohan, 2016. "Government subsidies for the Chinese photovoltaic industry," Energy Policy, Elsevier, vol. 99(C), pages 111-119.
    11. Ramakrishnan, Sayanthan & Wang, Xiaoming & Sanjayan, Jay & Wilson, John, 2017. "Thermal performance of buildings integrated with phase change materials to reduce heat stress risks during extreme heatwave events," Applied Energy, Elsevier, vol. 194(C), pages 410-421.
    12. Haolu Liu & Khurram Yousaf & Kunjie Chen & Rui Fan & Jiaxin Liu & Shakeel Ahmed Soomro, 2018. "Design and Thermal Analysis of an Air Source Heat Pump Dryer for Food Drying," Sustainability, MDPI, vol. 10(9), pages 1-17, September.
    13. Fan, Yuling & Xia, Xiaohua, 2018. "Building retrofit optimization models using notch test data considering energy performance certificate compliance," Applied Energy, Elsevier, vol. 228(C), pages 2140-2152.
    14. Iwaro, Joseph & Mwasha, Abraham, 2010. "A review of building energy regulation and policy for energy conservation in developing countries," Energy Policy, Elsevier, vol. 38(12), pages 7744-7755, December.
    15. Song, Mengjie & Gong, Guangcai & Mao, Ning & Deng, Shiming & Wang, Zhihua, 2017. "Experimental investigation on an air source heat pump unit with a three-circuit outdoor coil for its reverse cycle defrosting termination temperature," Applied Energy, Elsevier, vol. 204(C), pages 1388-1398.
    16. Yang, Liu & Yan, Haiyan & Lam, Joseph C., 2014. "Thermal comfort and building energy consumption implications – A review," Applied Energy, Elsevier, vol. 115(C), pages 164-173.
    17. Adnan Rasheed & Jong Won Lee & Hyeon Tae Kim & Hyun Woo Lee, 2022. "Study on Heating and Cooling Performance of Air-to-Water Heat Pump System for Protected Horticulture," Energies, MDPI, vol. 15(15), pages 1-19, July.
    18. Wei, Wenzhe & Ni, Long & Li, Shuyi & Wang, Wei & Yao, Yang & Xu, Laifu & Yang, Yahua, 2020. "A new frosting map of variable-frequency air source heat pump in severe cold region considering the variation of heating load," Renewable Energy, Elsevier, vol. 161(C), pages 184-199.
    19. Wang, Wei & Zhang, Shiqiang & Li, Zhaoyang & Sun, Yuying & Deng, Shiming & Wu, Xu, 2020. "Determination of the optimal defrosting initiating time point for an ASHP unit based on the minimum loss coefficient in the nominal output heating energy," Energy, Elsevier, vol. 191(C).
    20. Pu, Jihong & Shen, Chao & Zhang, Chunxiao & Liu, Xingjiang, 2021. "A semi-experimental method for evaluating frosting performance of air source heat pumps," Renewable Energy, Elsevier, vol. 173(C), pages 913-925.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:159:y:2018:i:c:p:724-736. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.