A model for estimation of daylight factor for skylight: An experimental validation using pyramid shape skylight over vault roof mud-house in New Delhi (India)

Author

Listed:
  • Chel, Arvind
  • Tiwari, G.N.
  • Chandra, Avinash

Abstract

A model to estimate daylight factor was investigated and validated using experimental hourly inside and outside illuminance data of an existing skylight integrated vault roof mud-house in composite climate of New Delhi. The daylight factor model was found in good agreement with experimental value of daylight factor. This model was modified for different practical horizontal surface levels inside the big and small dome rooms and validated using experimental measured data. The yearly average value of percentage daylight factor for big and small dome skylight rooms was determined as 2% and 6%, respectively. The total annual average artificial lighting energy saving potential of the skylight illuminance in the existing building was estimated as 973Â kWÂ h/year; corresponds to 1526Â kg/year of CO2 emission mitigation. Hence, the annual carbon credit potential from skylight mud-house building is [euro] 15.3/year.

Suggested Citation

  • Chel, Arvind & Tiwari, G.N. & Chandra, Avinash, 2009. "A model for estimation of daylight factor for skylight: An experimental validation using pyramid shape skylight over vault roof mud-house in New Delhi (India)," Applied Energy, Elsevier, vol. 86(11), pages 2507-2519, November.
  • Handle: RePEc:eee:appene:v:86:y:2009:i:11:p:2507-2519
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/B6V1T-4W1JY7V-1/2/e8599cb7f59d86908f8471dfa3276e35
    Download Restriction: Full text for ScienceDirect subscribers only
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Aries, Myriam B.C. & Newsham, Guy R., 2008. "Effect of daylight saving time on lighting energy use: A literature review," Energy Policy, Elsevier, vol. 36(6), pages 1858-1866, June.
    2. Jenkins, David & Newborough, Marcus, 2007. "An approach for estimating the carbon emissions associated with office lighting with a daylight contribution," Applied Energy, Elsevier, vol. 84(6), pages 608-622, June.
    3. Joshi, Mahendra & Sawhney, R.L. & Buddhi, D., 2007. "Estimation of Luminous efficacy of daylight and exterior illuminance for composite climate of Indore city in Mid Western India," Renewable Energy, Elsevier, vol. 32(8), pages 1363-1378.
    4. Greenup, P & Bell, J.M & Moore, I, 2001. "The importance of interior daylight distribution in buildings on overall energy performance," Renewable Energy, Elsevier, vol. 22(1), pages 45-52.
    5. Li, Danny H. W. & Lam, Joseph C., 2003. "An analysis of lighting energy savings and switching frequency for a daylit corridor under various indoor design illuminance levels," Applied Energy, Elsevier, vol. 76(4), pages 363-378, December.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Janjai, Serm & Plaon, Piyanuch, 2011. "Estimation of sky luminance in the tropics using artificial neural networks: Modeling and performance comparison with the CIE model," Applied Energy, Elsevier, vol. 88(3), pages 840-847, March.
    2. Freire, Roberto Zanetti & Mazuroski, Walter & Abadie, Marc Olivier & Mendes, Nathan, 2011. "Capacitive effect on the heat transfer through building glazing systems," Applied Energy, Elsevier, vol. 88(12), pages 4310-4319.
    3. Gago, E.J. & Muneer, T. & Knez, M. & Köster, H., 2015. "Natural light controls and guides in buildings. Energy saving for electrical lighting, reduction of cooling load," Renewable and Sustainable Energy Reviews, Elsevier, vol. 41(C), pages 1-13.
    4. Li, Danny H.W., 2010. "A review of daylight illuminance determinations and energy implications," Applied Energy, Elsevier, vol. 87(7), pages 2109-2118, July.
    5. Chel, Arvind & Tiwari, G.N. & Singh, H.N., 2010. "A modified model for estimation of daylight factor for skylight integrated with dome roof structure of mud-house in New Delhi (India)," Applied Energy, Elsevier, vol. 87(10), pages 3037-3050, October.
    6. Galatioto, A. & Beccali, M., 2016. "Aspects and issues of daylighting assessment: A review study," Renewable and Sustainable Energy Reviews, Elsevier, vol. 66(C), pages 852-860.
    7. Das, Aparna & Paul, Saikat Kumar, 2015. "Artificial illumination during daytime in residential buildings: Factors, energy implications and future predictions," Applied Energy, Elsevier, vol. 158(C), pages 65-85.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Chel, Arvind & Tiwari, G.N. & Singh, H.N., 2010. "A modified model for estimation of daylight factor for skylight integrated with dome roof structure of mud-house in New Delhi (India)," Applied Energy, Elsevier, vol. 87(10), pages 3037-3050, October.
    2. Carlucci, Salvatore & Causone, Francesco & De Rosa, Francesco & Pagliano, Lorenzo, 2015. "A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design," Renewable and Sustainable Energy Reviews, Elsevier, vol. 47(C), pages 1016-1033.
    3. Li, Danny H.W. & Lam, Tony N.T. & Chan, Wilco W.H. & Mak, Ada H.L., 2009. "Energy and cost analysis of semi-transparent photovoltaic in office buildings," Applied Energy, Elsevier, vol. 86(5), pages 722-729, May.
    4. Mangkuto, R.A. & Wang, S. & Meerbeek, B.W. & Aries, M.B.C. & van Loenen, E.J., 2014. "Lighting performance and electrical energy consumption of a virtual window prototype," Applied Energy, Elsevier, vol. 135(C), pages 261-273.
    5. Jenkins, David & Newborough, Marcus, 2007. "An approach for estimating the carbon emissions associated with office lighting with a daylight contribution," Applied Energy, Elsevier, vol. 84(6), pages 608-622, June.
    6. Galatioto, A. & Beccali, M., 2016. "Aspects and issues of daylighting assessment: A review study," Renewable and Sustainable Energy Reviews, Elsevier, vol. 66(C), pages 852-860.
    7. Gago, E.J. & Muneer, T. & Knez, M. & Köster, H., 2015. "Natural light controls and guides in buildings. Energy saving for electrical lighting, reduction of cooling load," Renewable and Sustainable Energy Reviews, Elsevier, vol. 41(C), pages 1-13.
    8. Li, Danny H.W., 2010. "A review of daylight illuminance determinations and energy implications," Applied Energy, Elsevier, vol. 87(7), pages 2109-2118, July.
    9. Salata, Ferdinando & Golasi, Iacopo & di Salvatore, Maicol & de Lieto Vollaro, Andrea, 2016. "Energy and reliability optimization of a system that combines daylighting and artificial sources. A case study carried out in academic buildings," Applied Energy, Elsevier, vol. 169(C), pages 250-266.
    10. Tomas Havranek, Dominik Herman, and Zuzana Irsova, 2018. "Does Daylight Saving Save Electricity? A Meta-Analysis," The Energy Journal, International Association for Energy Economics, vol. 0(Number 2).
    11. Matthew J. Kotchen & Laura E. Grant, 2011. "Does Daylight Saving Time Save Energy? Evidence from a Natural Experiment in Indiana," The Review of Economics and Statistics, MIT Press, vol. 93(4), pages 1172-1185, November.
    12. Karl Benediktsson & Stanley D. Brunn, 2015. "Time Zone Politics and Challenges of Globalisation," Tijdschrift voor Economische en Sociale Geografie, Royal Dutch Geographical Society KNAG, vol. 106(3), pages 276-290, July.
    13. Nicholas Rivers, 2018. "Does Daylight Savings Time Save Energy? Evidence from Ontario," Environmental & Resource Economics, Springer;European Association of Environmental and Resource Economists, vol. 70(2), pages 517-543, June.
    14. Wang, Zhu & Wang, Lingfeng & Dounis, Anastasios I. & Yang, Rui, 2012. "Multi-agent control system with information fusion based comfort model for smart buildings," Applied Energy, Elsevier, vol. 99(C), pages 247-254.
    15. Mavromatidis, Lazaros Elias & Marsault, Xavier & Lequay, Hervé, 2014. "Daylight factor estimation at an early design stage to reduce buildings' energy consumption due to artificial lighting: A numerical approach based on Doehlert and Box–Behnken designs," Energy, Elsevier, vol. 65(C), pages 488-502.
    16. Kai Zhang & Dong Yan, 2023. "Exploring Indoor and Outdoor Residential Factors of High-Density Communities for Promoting the Housing Development," Sustainability, MDPI, vol. 15(5), pages 1-18, March.
    17. Felix Weinhardt, 2013. "The Importance of Time Zone Assignment: Evidence from Residential Electricity Consumption," SERC Discussion Papers serddp0126, Centre for Economic Performance, LSE.
    18. Ahuja, Dilip R. & SenGupta, D.P., 2012. "Year-round daylight saving time will save more energy in India than corresponding DST or time zones," Energy Policy, Elsevier, vol. 42(C), pages 657-669.
    19. Evangelos-Nikolaos D. Madias & Lambros T. Doulos & Panagiotis A. Kontaxis & Frangiskos V. Topalis, 2022. "Multicriteria decision aid analysis for the optimum performance of an ambient light sensor: methodology and case study," Operational Research, Springer, vol. 22(2), pages 1333-1361, April.
    20. Joan Costa‐Font & Sarah Fleche & Ricardo Pagan, 2024. "The welfare effects of time reallocation: evidence from Daylight Saving Time," Economica, London School of Economics and Political Science, vol. 91(362), pages 547-568, April.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:86:y:2009:i:11:p:2507-2519. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.