Abstract

In this study, refrigerants R22 and R404A five of their binary mixtures which contain about 0%, 25%, 50%, 75% and 100% mass fractions of R404A were tested. It is investigated experimentally the effects of gas mixture rate, evaporator air inlet temperature (from 24 to 32 °C), evaporator air mass flow rate (from 0.58 to 0.74 kg/s), condenser air inlet temperature (from 22 to 34 °C) and condenser air mass flow rate (from 0.57 to 0.73 kg/s) on the coefficient of performance (COP) and exergetic efficiency values of vapor compression heat-pump systems. To determine the effect of the chosen parameters on the system and optimum working conditions, an experimental design method suggested by Genichi Taguchi was used. In this study, it was observed that the most effective parameters are found to be the condenser air inlet temperature for COP and exergetic efficiency.

Suggested Citation

  • Comakli, K. & Simsek, F. & Comakli, O. & Sahin, B., 2009. "Determination of optimum working conditions R22 and R404A refrigerant mixtures in heat-pumps using Taguchi method," Applied Energy, Elsevier, vol. 86(11), pages 2451-2458, November.
  • Handle: RePEc:eee:appene:v:86:y:2009:i:11:p:2451-2458
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306-2619(09)00076-2
    Download Restriction: Full text for ScienceDirect subscribers only
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Lu, S.-M. & Li, Y.-C.M. & Tang, J.-C., 2003. "Optimum design of natural-circulation solar-water-heater by the Taguchi method," Energy, Elsevier, vol. 28(7), pages 741-750.
    2. Nuntaphan, Atipoang & Chansena, Choosak & Kiatsiriroat, Tanongkiat, 2009. "Performance analysis of solar water heater combined with heat pump using refrigerant mixture," Applied Energy, Elsevier, vol. 86(5), pages 748-756, May.
    3. Cheong, K. W. & Riffat, S. B., 1996. "Monitoring hydrofluorocarbon refrigerant leakage from air-conditioning systems in buildings," Applied Energy, Elsevier, vol. 53(4), pages 341-347, April.
    4. Park, Ki-Jung & Seo, Taebeom & Jung, Dongsoo, 2007. "Performance of alternative refrigerants for residential air-conditioning applications," Applied Energy, Elsevier, vol. 84(10), pages 985-991, October.
    5. ArcaklIoglu, Erol & Çavusoglu, Abdullah & Erisen, Ali, 2004. "Thermodynamic analyses of refrigerant mixtures using artificial neural networks," Applied Energy, Elsevier, vol. 78(2), pages 219-230, June.
    6. Park, Ki-Jung & Shim, Yun-Bo & Jung, Dongsoo, 2008. "Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps," Applied Energy, Elsevier, vol. 85(9), pages 896-900, September.
    7. Wu, Shenyi & Eames, Ian W., 2000. "Innovations in vapour-absorption cycles," Applied Energy, Elsevier, vol. 66(3), pages 251-266, July.
    8. Ge, Y.T. & Cropper, R., 2008. "Performance simulation of refrigerated display cabinets operating with refrigerants R22 and R404A," Applied Energy, Elsevier, vol. 85(8), pages 694-707, August.
    9. Smith, S. J. & Shao, L. & Riffat, S. B., 2001. "Pressure drop of HFC refrigerants inside evaporator and condenser coils as determined by CFD," Applied Energy, Elsevier, vol. 70(2), pages 169-178, October.
    10. Perez-Blanco, H. & Kim, Kyoung-Hoon & Ream, Stephen, 2007. "Evaporatively-cooled compression using a high-pressure refrigerant," Applied Energy, Elsevier, vol. 84(10), pages 1028-1043, October.
    11. Ge, Yunting & Cropper, Roy, 2004. "Air-cooled condensers in retail systems using R22 and R404A refrigerants," Applied Energy, Elsevier, vol. 78(1), pages 95-110, May.
    12. Medrano, M. & Bourouis, M. & Coronas, A., 2001. "Double-lift absorption refrigeration cycles driven by low-temperature heat sources using organic fluid mixtures as working pairs," Applied Energy, Elsevier, vol. 68(2), pages 173-185, February.
    13. Nanxi, Liu & Shi, Lin & Lizhong, Han & Mingshan, Zhu, 2005. "Moderately high temperature water source heat-pumps using a near-azeotropic refrigerant mixture," Applied Energy, Elsevier, vol. 80(4), pages 435-447, April.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Çakır, Uğur & Çomaklı, Kemal & Çomaklı, Ömer & Karslı, Süleyman, 2013. "An experimental exergetic comparison of four different heat pump systems working at same conditions: As air to air, air to water, water to water and water to air," Energy, Elsevier, vol. 58(C), pages 210-219.
    2. Yang, Yang & Zhou, Ling & Hang, Jianwei & Du, Danyang & Shi, Weidong & He, Zhaoming, 2021. "Energy characteristics and optimal design of diffuser meridian in an electrical submersible pump," Renewable Energy, Elsevier, vol. 167(C), pages 718-727.
    3. Shao, Liang-Liang & Yang, Liang & Zhang, Chun-Lu, 2010. "Comparison of heat pump performance using fin-and-tube and microchannel heat exchangers under frost conditions," Applied Energy, Elsevier, vol. 87(4), pages 1187-1197, April.
    4. Chen, Wen-Lih & Currao, Gaetano & Li, Yueh-Heng & Kao, Chien-Chun, 2023. "Employing Taguchi method to optimize the performance of a microscale combined heat and power system with Stirling engine and thermophotovoltaic array," Energy, Elsevier, vol. 270(C).
    5. Tang, Jinchen & Gong, Guangcai & Su, Huan & Wu, Fanhao & Herman, Cila, 2016. "Performance evaluation of a novel method of frost prevention and retardation for air source heat pumps using the orthogonal experiment design method," Applied Energy, Elsevier, vol. 169(C), pages 696-708.
    6. Guo, J.J. & Wu, J.Y. & Wang, R.Z. & Li, S., 2011. "Experimental research and operation optimization of an air-source heat pump water heater," Applied Energy, Elsevier, vol. 88(11), pages 4128-4138.
    7. Zhang, Long & Jiang, Yiqiang & Dong, Jiankai & Yao, Yang, 2018. "Advances in vapor compression air source heat pump system in cold regions: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 81(P1), pages 353-365.
    8. Chua, K.J. & Chou, S.K. & Yang, W.M., 2010. "Advances in heat pump systems: A review," Applied Energy, Elsevier, vol. 87(12), pages 3611-3624, December.
    9. Liu, Qingsong & Miao, Weipao & Li, Chun & Hao, Winxing & Zhu, Haitian & Deng, Yunhe, 2019. "Effects of trailing-edge movable flap on aerodynamic performance and noise characteristics of VAWT," Energy, Elsevier, vol. 189(C).

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Zhou, Guobing & Zhang, Yufeng, 2010. "Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290," Applied Energy, Elsevier, vol. 87(5), pages 1522-1528, May.
    2. Zhang, Shengjun & Wang, Huaixin & Guo, Tao, 2010. "Experimental investigation of moderately high temperature water source heat pump with non-azeotropic refrigerant mixtures," Applied Energy, Elsevier, vol. 87(5), pages 1554-1561, May.
    3. Le Lostec, Brice & Galanis, Nicolas & Baribeault, Jean & Millette, Jocelyn, 2008. "Wood chip drying with an absorption heat pump," Energy, Elsevier, vol. 33(3), pages 500-512.
    4. Guo, Hao & Gong, Maoqiong & Qin, Xiaoyu, 2019. "Performance analysis of a modified subcritical zeotropic mixture recuperative high-temperature heat pump," Applied Energy, Elsevier, vol. 237(C), pages 338-352.
    5. Yang, Zhao & Wu, Xi, 2013. "Retrofits and options for the alternatives to HCFC-22," Energy, Elsevier, vol. 59(C), pages 1-21.
    6. Sun, Zhili & Liang, Youcai & Liu, Shengchun & Ji, Weichuan & Zang, Runqing & Liang, Rongzhen & Guo, Zhikai, 2016. "Comparative analysis of thermodynamic performance of a cascade refrigeration system for refrigerant couples R41/R404A and R23/R404A," Applied Energy, Elsevier, vol. 184(C), pages 19-25.
    7. Wang, Q. & Li, D.H. & Wang, J.P. & Sun, T.F. & Han, X.H. & Chen, G.M., 2013. "Numerical investigations on the performance of a single-stage auto-cascade refrigerator operating with two vapor–liquid separators and environmentally benign binary refrigerants," Applied Energy, Elsevier, vol. 112(C), pages 949-955.
    8. Zhang, Jing & Zhang, Hong-Hu & He, Ya-Ling & Tao, Wen-Quan, 2016. "A comprehensive review on advances and applications of industrial heat pumps based on the practices in China," Applied Energy, Elsevier, vol. 178(C), pages 800-825.
    9. Kutub Uddin & Bidyut Baran Saha, 2022. "An Overview of Environment-Friendly Refrigerants for Domestic Air Conditioning Applications," Energies, MDPI, vol. 15(21), pages 1-24, October.
    10. Wu, Wei & Shi, Wenxing & Wang, Jian & Wang, Baolong & Li, Xianting, 2016. "Experimental investigation on NH3–H2O compression-assisted absorption heat pump (CAHP) for low temperature heating under lower driving sources," Applied Energy, Elsevier, vol. 176(C), pages 258-271.
    11. Megdouli, K. & Ejemni, N. & Nahdi, E. & Mhimid, A. & Kairouani, L., 2017. "Thermodynamic analysis of a novel ejector expansion transcritical CO2/N2O cascade refrigeration (NEETCR) system for cooling applications at low temperatures," Energy, Elsevier, vol. 128(C), pages 586-600.
    12. Rameshkumar, A. & Udayakumar, M. & Saravanan, R., 2009. "Heat transfer studies on a GAXAC (generator-absorber-exchange absorption compression) cooler," Applied Energy, Elsevier, vol. 86(10), pages 2056-2064, October.
    13. Khargotra, Rohit & Kumar, Raj & András, Kovács & Fekete, Gusztáv & Singh, Tej, 2022. "Thermo-hydraulic characterization and design optimization of delta-shaped obstacles in solar water heating system using CRITIC-COPRAS approach," Energy, Elsevier, vol. 261(PB).
    14. Lv, Xiaolong & Yan, Gang & Yu, Jianlin, 2015. "Solar-assisted auto-cascade heat pump cycle with zeotropic mixture R32/R290 for small water heaters," Renewable Energy, Elsevier, vol. 76(C), pages 167-172.
    15. Vereda, C. & Ventas, R. & Lecuona, A. & Venegas, M., 2012. "Study of an ejector-absorption refrigeration cycle with an adaptable ejector nozzle for different working conditions," Applied Energy, Elsevier, vol. 97(C), pages 305-312.
    16. Bose, Probir Kumar & Deb, Madhujit & Banerjee, Rahul & Majumder, Arindam, 2013. "Multi objective optimization of performance parameters of a single cylinder diesel engine running with hydrogen using a Taguchi-fuzzy based approach," Energy, Elsevier, vol. 63(C), pages 375-386.
    17. Wang, Meng & Infante Ferreira, Carlos A., 2017. "Absorption heat pump cycles with NH3 – ionic liquid working pairs," Applied Energy, Elsevier, vol. 204(C), pages 819-830.
    18. Chandan Swaroop Meena & Binju P Raj & Lohit Saini & Nehul Agarwal & Aritra Ghosh, 2021. "Performance Optimization of Solar-Assisted Heat Pump System for Water Heating Applications," Energies, MDPI, vol. 14(12), pages 1-17, June.
    19. Park, Ki-Jung & Shim, Yun-Bo & Jung, Dongsoo, 2008. "Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps," Applied Energy, Elsevier, vol. 85(9), pages 896-900, September.
    20. Mohanraj, M. & Belyayev, Ye. & Jayaraj, S. & Kaltayev, A., 2018. "Research and developments on solar assisted compression heat pump systems – A comprehensive review (Part A: Modeling and modifications)," Renewable and Sustainable Energy Reviews, Elsevier, vol. 83(C), pages 90-123.

    More about this item

    Keywords

    Heat-pump Gas mixture R404A R22 Taguchi method;

    JEL classification:

    • R22 - Urban, Rural, Regional, Real Estate, and Transportation Economics - - Household Analysis - - - Other Demand

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:86:y:2009:i:11:p:2451-2458. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.