IDEAS home Printed from https://ideas.repec.org/h/spr/sprchp/978-3-540-75999-7_113.html

Analysis of Pre-Tightened Bolt Connections under Eccentric Load

In: Computational Mechanics

Author

Listed:
  • Jun Wang

    (The Chinese Academy of Engineering Physics, Institute of Structure Mechanics)

  • Zhiming Hao

    (The Chinese Academy of Engineering Physics, Institute of Structure Mechanics)

  • Y. H. Yin

    (The Chinese Academy of Engineering Physics, Institute of Structure Mechanics)

  • Pingan Shi

    (The Chinese Academy of Engineering Physics, Institute of Structure Mechanics)

  • Bing Xu

    (The Chinese Academy of Engineering Physics, Institute of Structure Mechanics)

Abstract

Besides eccentric load, the bolt in the pre-tightening bolt connections is loaded by the axis-force P and the bend moment. The FEM method was used to analysis pre-tightening bolt connections under eccentric load. In the finite element analysis model, diameter of screw is 14mm, and diameter of bolt is 12mm. The material of bolt is 20Crl3, E=220GPa, v=0.3, σs=700MPa, the material of nut is Zr+2.5%Nb, E=88GPa, v=0.3, σs=235MPa, σh=392MPa. During the first analysis, Considered the contact between the nut and the below flange, the nut contact with the below flange at left side, the bolt contact with the screw, the length of contact between nut and the below flange at right side is 1.36 mm, and the width of nut upper flat roof is 14.17mm. The result of the analysis is that the σmax of bolt is 480.6MPa and the σmax of nut is 233MPa. The structure is safe. And during the second analysis, the new model which based on the data of measures described as below: The contact range is about 120°, and the bolt axis inosculate with the screw axis (the nut was erased for 2.7 mm at the left side, at the same time it went up for 2.07 mm). Considered the contact of nut and below flange, the nut full contact with the below at left side, the length of contact is 1.87 mm at right side, and the width of nut upper flat roof is 9.64 mm. The result of the analysis shows that the σmax of bolt is 578.1MPa and the σmax of nut is 235.1MPa. The structure is safe.

Suggested Citation

  • Jun Wang & Zhiming Hao & Y. H. Yin & Pingan Shi & Bing Xu, 2007. "Analysis of Pre-Tightened Bolt Connections under Eccentric Load," Springer Books, in: Computational Mechanics, pages 313-313, Springer.
  • Handle: RePEc:spr:sprchp:978-3-540-75999-7_113
    DOI: 10.1007/978-3-540-75999-7_113
    as

    Download full text from publisher

    To our knowledge, this item is not available for download. To find whether it is available, there are three options:
    1. Check below whether another version of this item is available online.
    2. Check on the provider's web page whether it is in fact available.
    3. Perform a
    for a similarly titled item that would be available.

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:spr:sprchp:978-3-540-75999-7_113. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.springer.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.