IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0253096.html
   My bibliography  Save this article

Estimating ventilation rates in rooms with varying occupancy levels: Relevance for reducing transmission risk of airborne pathogens

Author

Listed:
  • Arminder K Deol
  • Danny Scarponi
  • Peter Beckwith
  • Tom A Yates
  • Aaron S Karat
  • Ada W C Yan
  • Kathy S Baisley
  • Alison D Grant
  • Richard G White
  • Nicky McCreesh

Abstract

Background: In light of the role that airborne transmission plays in the spread of SARS-CoV-2, as well as the ongoing high global mortality from well-known airborne diseases such as tuberculosis and measles, there is an urgent need for practical ways of identifying congregate spaces where low ventilation levels contribute to high transmission risk. Poorly ventilated clinic spaces in particular may be high risk, due to the presence of both infectious and susceptible people. While relatively simple approaches to estimating ventilation rates exist, the approaches most frequently used in epidemiology cannot be used where occupancy varies, and so cannot be reliably applied in many of the types of spaces where they are most needed. Methods: The aim of this study was to demonstrate the use of a non-steady state method to estimate the absolute ventilation rate, which can be applied in rooms where occupancy levels vary. We used data from a room in a primary healthcare clinic in a high TB and HIV prevalence setting, comprising indoor and outdoor carbon dioxide measurements and head counts (by age), taken over time. Two approaches were compared: approach 1 using a simple linear regression model and approach 2 using an ordinary differential equation model. Results: The absolute ventilation rate, Q, using approach 1 was 2407 l/s [95% CI: 1632–3181] and Q from approach 2 was 2743 l/s [95% CI: 2139–4429]. Conclusions: We demonstrate two methods that can be used to estimate ventilation rate in busy congregate settings, such as clinic waiting rooms. Both approaches produced comparable results, however the simple linear regression method has the advantage of not requiring room volume measurements. These methods can be used to identify poorly-ventilated spaces, allowing measures to be taken to reduce the airborne transmission of pathogens such as Mycobacterium tuberculosis, measles, and SARS-CoV-2.

Suggested Citation

  • Arminder K Deol & Danny Scarponi & Peter Beckwith & Tom A Yates & Aaron S Karat & Ada W C Yan & Kathy S Baisley & Alison D Grant & Richard G White & Nicky McCreesh, 2021. "Estimating ventilation rates in rooms with varying occupancy levels: Relevance for reducing transmission risk of airborne pathogens," PLOS ONE, Public Library of Science, vol. 16(6), pages 1-12, June.
  • Handle: RePEc:plo:pone00:0253096
    DOI: 10.1371/journal.pone.0253096
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0253096
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0253096&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0253096?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    References listed on IDEAS

    as
    1. Adrian Roderick Escombe & David A J Moore & Jon S Friedland & Carlton A Evans & Robert H Gilman, 2007. "Natural Ventilation for Prevention of Airborne Contagion: Authors' Reply," PLOS Medicine, Public Library of Science, vol. 4(5), pages 1-2, May.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Noor Muhammad Abd Rahman & Lim Chin Haw & Ahmad Fazlizan, 2021. "A Literature Review of Naturally Ventilated Public Hospital Wards in Tropical Climate Countries for Thermal Comfort and Energy Saving Improvements," Energies, MDPI, vol. 14(2), pages 1-22, January.
    2. Szu‐Chieh Chen & Chung‐Min Liao & Sih‐Syuan Li & Shu‐Han You, 2011. "A Probabilistic Transmission Model to Assess Infection Risk from Mycobacterium Tuberculosis in Commercial Passenger Trains," Risk Analysis, John Wiley & Sons, vol. 31(6), pages 930-939, June.
    3. Dohyeong Kim & Hee-Eun Choi & Won-Mo Gal & SungChul Seo, 2020. "Five Year Trends of Particulate Matter Concentrations in Korean Regions (2015–2019): When to Ventilate?," IJERPH, MDPI, vol. 17(16), pages 1-15, August.
    4. Suyan Yi & Hongwei Wang & Shengtian Yang & Ling Xie & Yibo Gao & Chen Ma, 2021. "Spatial and Temporal Characteristics of Hand-Foot-and-Mouth Disease and Its Response to Climate Factors in the Ili River Valley Region of China," IJERPH, MDPI, vol. 18(4), pages 1-13, February.
    5. Pradeep Shakya & Gimson Ng & Xiaoli Zhou & Yew Wah Wong & Swapnil Dubey & Shunzhi Qian, 2021. "Thermal Comfort and Energy Analysis of a Hybrid Cooling System by Coupling Natural Ventilation with Radiant and Indirect Evaporative Cooling," Energies, MDPI, vol. 14(22), pages 1-19, November.
    6. Aviv, Dorit & Chen, Kian Wee & Teitelbaum, Eric & Sheppard, Denon & Pantelic, Jovan & Rysanek, Adam & Meggers, Forrest, 2021. "A fresh (air) look at ventilation for COVID-19: Estimating the global energy savings potential of coupling natural ventilation with novel radiant cooling strategies," Applied Energy, Elsevier, vol. 292(C).
    7. Marco Gola & Gaetano Settimo & Stefano Capolongo, 2020. "How Can Design Features and Other Factors Affect the Indoor Air Quality in Inpatient Rooms? Check-Lists for the Design Phase, Daily Procedures and Maintenance Activities for Reducing the Air Concentra," IJERPH, MDPI, vol. 17(12), pages 1-20, June.
    8. Xiaolei Gao & Jianjian Wei & Hao Lei & Pengcheng Xu & Benjamin J Cowling & Yuguo Li, 2016. "Building Ventilation as an Effective Disease Intervention Strategy in a Dense Indoor Contact Network in an Ideal City," PLOS ONE, Public Library of Science, vol. 11(9), pages 1-20, September.
    9. Marco Gola & Gaetano Settimo & Stefano Capolongo, 2019. "Chemical Pollution in Healing Spaces: The Decalogue of the Best Practices for Adequate Indoor Air Quality in Inpatient Rooms," IJERPH, MDPI, vol. 16(22), pages 1-15, November.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0253096. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.