Author
Listed:
- Ali Riahi
(River Engineering and Urban Drainage Research Centre (REDAC), Universiti Sains Malaysia, Nibong Tebal 14300, Penang, Malaysia)
- Nor Azazi Zakaria
(River Engineering and Urban Drainage Research Centre (REDAC), Universiti Sains Malaysia, Nibong Tebal 14300, Penang, Malaysia)
- Nasir Md Noh
(National Water Research Institute of Malaysia (NAHRIM), Lot 5377, Jalan Putra Permai, Seri Kembangan 43300, Selangor Darul Ehsan, Malaysia)
- Mohd Zaki Mat Amin
(National Water Research Institute of Malaysia (NAHRIM), Lot 5377, Jalan Putra Permai, Seri Kembangan 43300, Selangor Darul Ehsan, Malaysia)
- Azman Mat Jusoh
(National Water Research Institute of Malaysia (NAHRIM), Lot 5377, Jalan Putra Permai, Seri Kembangan 43300, Selangor Darul Ehsan, Malaysia)
- Marini Mohamad Ideris
(National Water Research Institute of Malaysia (NAHRIM), Lot 5377, Jalan Putra Permai, Seri Kembangan 43300, Selangor Darul Ehsan, Malaysia)
- Mohd Zharif Muhammad
(National Water Research Institute of Malaysia (NAHRIM), Lot 5377, Jalan Putra Permai, Seri Kembangan 43300, Selangor Darul Ehsan, Malaysia)
- Mohd Asri Ramli
(National Water Research Institute of Malaysia (NAHRIM), Lot 5377, Jalan Putra Permai, Seri Kembangan 43300, Selangor Darul Ehsan, Malaysia)
- Mohd Remy Rozainy Mohd Arif Zainol
(River Engineering and Urban Drainage Research Centre (REDAC), Universiti Sains Malaysia, Nibong Tebal 14300, Penang, Malaysia)
- Syafiq Shaharuddin
(River Engineering and Urban Drainage Research Centre (REDAC), Universiti Sains Malaysia, Nibong Tebal 14300, Penang, Malaysia)
- Mohd Fazly Yusof
(River Engineering and Urban Drainage Research Centre (REDAC), Universiti Sains Malaysia, Nibong Tebal 14300, Penang, Malaysia)
Abstract
In this work, an atmospheric water generator (AWG) system called the medium-scale AWG (MSAWG) was designed, fabricated, and tested in Universiti Sains Malaysia (USM) under the outdoor tropical climate conditions of Malaysia to investigate the amount of fresh water production in successive periods of 24 h. The MSAWG consisted of 18 thermoelectric cooler (TEC) units, 18 internal finned heat sinks, 18 external finned heat sinks, 18 direct current (DC) cooling fans, an air-conditioner mesh air filter, and an axial ventilation fan. It was found from the results that the hourly values of water production of MSAWG were proportional to the hourly rates of relative humidity, but they were inversely affected by the corresponding hourly values of the ambient temperature. Night-time and early morning were the most effective times to produce the highest amount of fresh water from Malaysia’s atmosphere using MSAWG, as the increase in the rates of relative humidity and the decrease in the values of ambient temperature occurred over these periods. Based on the varied hourly rates of relative humidity with the ranges between the minimum rate of 55% and maximum rate of 85%, an equation of Y = 0.2285X + 36.675 with R 2 of 0.9404 was achieved from the 48 h experimental work to estimate the water production of MSAWG in Malaysia, where Y and X were indicated as the rate of relative humidity and the value of water production, respectively, in this equation. In conclusion, the MSAWG produced a consecutive cumulative water volume of 3.432 and 6.997 L experimentally in the periods of 24 and 48 h, respectively. The estimated cost per liter for MSAWG was USD 0.466. Some water quality parameters of the fresh water produced by MSAWG were analysed in the laboratory, which showed that they met the World Health Organization (WHO) drinking water standards. Therefore, MSAWG can be employed as a sustainable alternative to generate annual daily fresh water from Malaysia’s tropical atmosphere and aid in mitigating the problem of unpredicted water shortage in the country.
Suggested Citation
Ali Riahi & Nor Azazi Zakaria & Nasir Md Noh & Mohd Zaki Mat Amin & Azman Mat Jusoh & Marini Mohamad Ideris & Mohd Zharif Muhammad & Mohd Asri Ramli & Mohd Remy Rozainy Mohd Arif Zainol & Syafiq Shaha, 2021.
"Performance Investigation of 18 Thermoelectric Cooler (TEC) Units to Supply Continuous Daily Fresh Water from Malaysia’s Atmosphere,"
Sustainability, MDPI, vol. 13(3), pages 1-16, January.
Handle:
RePEc:gam:jsusta:v:13:y:2021:i:3:p:1399-:d:489278
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:13:y:2021:i:3:p:1399-:d:489278. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.