IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v19y2022i4p2309-d751861.html
   My bibliography  Save this article

Application of Solid-Phase Extraction and High-Performance Liquid Chromatography with Fluorescence Detection to Analyze Eleven Bisphenols in Amniotic Fluid Samples Collected during Amniocentesis

Author

Listed:
  • Tomasz Tuzimski

    (Department of Physical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland)

  • Szymon Szubartowski

    (Department of Physical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland
    Doctoral School of Medical University of Lublin, Medical University of Lublin, Chodźki 7, 20-093 Lublin, Poland)

Abstract

Amniocentesis involves taking a sample of the amniotic fluid in order to perform a karyotype test and diagnose any genetic defects that may affect the fetus. Amniotic fluid has been collected from patients with an indication for amniocentesis in the 15–26th week of pregnancy. A simple and sensitive high-performance liquid chromatography with fluorescence detection (HPLC-FLD) method for identification and quantification of eleven selected bisphenols in amniotic fluid samples is proposed. The proposed method involved protein precipitation using acetonitrile, and next the extraction and concentration of analytes by solid-phase extraction (SPE). The solid-phase extraction (SPE) procedure with application of Oasis HLB SPE columns performed well for the majority of the analytes, with recoveries in the range of 67–121% and relative standard deviations (RSD%) less than 16%. The limits of detection (LODs) and quantification (LOQs) of all the investigated analytes were in the range of 0.8–2.5 ng mL −1 and 2.4–7.5 ng mL −1 (curves constructed in methanol) and 1.1–5.2 ng mL −1 and 3.2–15.6 ng mL −1 (curves constructed in the amniotic fluid), respectively. The method was validated at the following two concentration levels: 10 ng mL −1 (2 × LOQ) and 20 ng mL −1 (4 LOQ). The results confirm the validity of the SPE procedure and HPLC-FLD method for identification and quantification of bisphenols in amniotic fluid samples collected during an amniocentesis. The result obtained show that HPLC-FLD is a useful method for determination of bisphenol residues at nanogram per milliliter concentrations in amniotic fluid samples. Residues of five analytes (BADGE·2H 2 O, BPAF, BADGE, BADGE·H 2 O·HCl and BADGE·2HCl) were detected in amniotic fluid samples. Additionally, the harmfulness of bisphenols as potential pathogens that may cause karyotype disorders and contribute to preterm birth was estimated.

Suggested Citation

  • Tomasz Tuzimski & Szymon Szubartowski, 2022. "Application of Solid-Phase Extraction and High-Performance Liquid Chromatography with Fluorescence Detection to Analyze Eleven Bisphenols in Amniotic Fluid Samples Collected during Amniocentesis," IJERPH, MDPI, vol. 19(4), pages 1-17, February.
  • Handle: RePEc:gam:jijerp:v:19:y:2022:i:4:p:2309-:d:751861
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/19/4/2309/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/19/4/2309/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Tomasz Tuzimski & Szymon Szubartowski, 2021. "Application of Solid Phase Extraction and High-Performance Liquid Chromatography with Fluorescence Detection to Analyze Bisphenol A Bis (2,3-Dihydroxypropyl) Ether (BADGE 2H 2 O), Bisphenol F (BPF), a," IJERPH, MDPI, vol. 18(19), pages 1-15, September.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Szymon Szubartowski & Tomasz Tuzimski, 2022. "Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid ," IJERPH, MDPI, vol. 20(1), pages 1-14, December.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Szymon Szubartowski & Tomasz Tuzimski, 2022. "Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid–Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid ," IJERPH, MDPI, vol. 20(1), pages 1-14, December.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:4:p:2309-:d:751861. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.