IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v18y2025i16p4329-d1724389.html
   My bibliography  Save this article

Gramian Angular Field–Gramian Adversial Network–ResNet34: High-Accuracy Fault Diagnosis for Transformer Windings with Limited Samples

Author

Listed:
  • Hongwen Liu

    (Electric Power Research Institute of Yunnan Power Grid, Kunming 650214, China)

  • Kun Yang

    (Electric Power Research Institute of Yunnan Power Grid, Kunming 650214, China)

  • Guochao Qian

    (Electric Power Research Institute of Yunnan Power Grid, Kunming 650214, China)

  • Jin Hu

    (Electric Power Research Institute of Yunnan Power Grid, Kunming 650214, China)

  • Weiju Dai

    (Electric Power Research Institute of Yunnan Power Grid, Kunming 650214, China)

  • Liang Zhu

    (Electric Power Research Institute of Yunnan Power Grid, Kunming 650214, China)

  • Tao Guo

    (Electric Power Research Institute of Yunnan Power Grid, Kunming 650214, China)

  • Jun Shi

    (Electric Power Research Institute of Yunnan Power Grid, Kunming 650214, China)

  • Dongyang Wang

    (School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China)

Abstract

Transformers are critical equipment in power transmission and distribution systems, and the condition of their windings significantly impacts their reliable operation. Therefore, the fault diagnosis of transformer windings is of great importance. Addressing the challenge of limited fault samples in traditional diagnostic methods, this study proposes a small-sample fault diagnosis method for transformer windings. This method combines data augmentation using the Gramian angular field (GAF) and generative adversarial networks (GAN) with a deep residual network (ResNet). First, by establishing a transformer winding fault simulation experiment platform, frequency response curves for three types of faults—axial displacement, bulging and warping, and cake-to-cake short circuits—and different fault regions were obtained using the frequency response analysis method (FRA). Second, a frequency response curve image conversion technique based on the Gramian angular field was proposed, converting the frequency response curves into Gramian angular summation field (GASF) and Gramian angular difference field (GADF) images using the Gramian angular field. Next, we introduce several improved GANs to augment the frequency response data and evaluate the quality of the generated samples. We compared and analysed the diagnostic accuracy of ResNet34 networks trained using different GAF–GAN combination datasets for winding fault types, and we proposed a transformer winding small-sample fault diagnosis method based on GAF-GAN-ResNet34, which can achieve a fault identification accuracy rate of 96.88% even when using only 28 real samples. Finally, we applied the proposed fault diagnosis method to on-site transformers to verify its classification performance under small-sample conditions. The results show that, even with insufficient fault samples, the proposed method can achieve high diagnostic accuracy.

Suggested Citation

  • Hongwen Liu & Kun Yang & Guochao Qian & Jin Hu & Weiju Dai & Liang Zhu & Tao Guo & Jun Shi & Dongyang Wang, 2025. "Gramian Angular Field–Gramian Adversial Network–ResNet34: High-Accuracy Fault Diagnosis for Transformer Windings with Limited Samples," Energies, MDPI, vol. 18(16), pages 1-19, August.
  • Handle: RePEc:gam:jeners:v:18:y:2025:i:16:p:4329-:d:1724389
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/18/16/4329/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/18/16/4329/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:16:p:4329-:d:1724389. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.