Author
Listed:
- Weifeng Qin
(Nanxun Innovation Institute, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China)
- Jianfeng Yao
(Nanxun Innovation Institute, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
Energy Engineering Group Zhejiang Power Design Institute Co., Ltd., Hangzhou 310012, China
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China)
- Zhitong Liu
(Nanxun Innovation Institute, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China)
- Yong Guo
(Energy Engineering Group Zhejiang Power Design Institute Co., Ltd., Hangzhou 310012, China)
- Guohui Shen
(College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China)
- Zhibin Tu
(Nanxun Innovation Institute, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China)
Abstract
To investigate the failure evolution and structural response of transmission towers under the combined effects of foundation sliding and wind loads, this study used the foundation sliding incident of Tower No. 39 on the Xiaoxing transmission line as a case for numerical back-analysis. A transmission tower model was first developed based on the finite element method, and the simulation results were compared with field observations to validate the model, with particular focus on the consistency of typical failure modes such as leg bending and cross-bracing instability. On this basis, the structural response under the combined action of foundation lateral displacement, settlement, and wind loads was further simulated. The results indicate that foundation sliding significantly affects the structural stability of transmission towers, with single-foundation sliding being more destructive than the simultaneous sliding of multiple foundations on the same side. Moreover, the coupling of foundation sliding and wind load substantially reduces the critical displacement required to trigger structural failure. Finally, critical displacement thresholds are proposed, which can serve as reference criteria for damage assessment and engineering intervention when changes in foundation conditions occur.
Suggested Citation
Weifeng Qin & Jianfeng Yao & Zhitong Liu & Yong Guo & Guohui Shen & Zhibin Tu, 2025.
"Structural Response and Failure Analysis of Transmission Towers Under Foundation Sliding with Consideration of Wind Effects,"
Energies, MDPI, vol. 18(11), pages 1-20, May.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:11:p:2878-:d:1668627
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:11:p:2878-:d:1668627. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.