Abstract
With the growing use of photovoltaic panels in buildings, concerns over their fire safety have increased. However, the influence of front-glass type and its fracture behaviour in fires remains insufficiently understood. This study examines the combustion characteristics of monocrystalline silicon photovoltaic panels using both annealed (non-tempered) and tempered glass surfaces, with a specific focus on the interaction between glass fracture and ignition development. A total of 17 cone calorimeter tests were conducted under heat fluxes of 50, 60, and 65 kW/m2. Thermal decomposition behaviours were further characterised using TG-IR-GC-MS analyses. Results showed that annealed glass fractured earlier under thermal stress, while tempered glass fractured later or remained intact, depending on the heat flux. At 65 kW/m2, annealed panels fractured significantly earlier ((38 ± 16) s) but ignited later at (330 ± 33) s. In contrast, tempered panels fractured at (177 ± 36) s and ignited earlier at (228 ± 9) s. Ignition was most delayed (353 s) when the glass surface remained fully intact. This is due to the dense network of cracks that forms in tempered glass after fracture, which enhances fuel–air mixing and accelerates ignition. Thermal analysis further revealed that combustion of photovoltaic panels produces toxic volatiles, including acetic acid, carbon monoxide, carbon dioxide, and hydrogen fluoride. The toxic emissions appeared above the temperature of 300 °C and intensified above the temperature of 500 °C, which were linked to the staged decomposition of the EVA and TPT layers. These findings highlight that the timing and pattern of glass fracture critically influence heat accumulation and vapour release, thereby affecting ignition location and intensity.
Suggested Citation
Hu, Yiyang & Li, Xiaoqing & Chu, Wei & Bedon, Chiara & Wang, Yu, 2026.
"Impact of glass fracture on the fire behaviour of single-glazed monocrystalline silicon photovoltaic panels,"
Renewable Energy, Elsevier, vol. 259(C).
Handle:
RePEc:eee:renene:v:259:y:2026:i:c:s0960148125027429
DOI: 10.1016/j.renene.2025.125078
Download full text from publisher
As the access to this document is restricted, you may want to
for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:259:y:2026:i:c:s0960148125027429. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.