Author
Listed:
- Zheng, Lingling
- Zhong, Wei
- Peng, Yucheng
- Yu, Hangyu
- Yuan, Yanping
Abstract
High-performance Heating, Ventilation and Air Conditioning (HVAC) terminal devices that use Flat Microchannel Heat Pipes reduce energy consumption and enhance indoor thermal comfort. With compact structures and excellent heat transfer, they have broad application prospects as cooling terminals. This study experimentally investigated the startup characteristics, condensation performance, and thermal resistance distribution under low-temperature-difference conditions. A combined experimental and numerical simulation approach was employed to analyze the influence of ambient temperature and humidity on system performance. The findings reveal that the simulation accurately predicts the local wall temperatures condensation section under various boundary conditions. Furthermore, the established heat transfer model shows good agreement with the experimental data, with deviations within ±1.5 %. This model effectively predicts key parameters such as the surface temperature and variations in the liquid film thickness. The results indicate that when the ambient temperature is 36 °C and the relative humidity exceeds 60 %, the condensate from dewing affects the surface temperature of the heat pipe and increases the heat transfer rate, while the thermal resistance in each zone remains relatively constant. The flat microchannel heat pipe is divided into three zones along the coolant flow direction. Due to non-uniform heat transfer, Zone 1 exhibits the lowest thermal resistance (0.08–0.13 K/W), whereas Zone 3 shows the highest (0.27–0.96 K/W). Increasing coolant flow rate improves overall heat transfer; lowering coolant temperature reduces total thermal resistance. This study provides a basis for the optimized design of cooling systems and validates the potential in improving building energy efficiency.
Suggested Citation
Zheng, Lingling & Zhong, Wei & Peng, Yucheng & Yu, Hangyu & Yuan, Yanping, 2026.
"Thermal performance of a flat microchannel heat pipe for convective cooling terminal under low-temperature differences,"
Energy, Elsevier, vol. 345(C).
Handle:
RePEc:eee:energy:v:345:y:2026:i:c:s0360544226002628
DOI: 10.1016/j.energy.2026.140160
Download full text from publisher
As the access to this document is restricted, you may want to
for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:345:y:2026:i:c:s0360544226002628. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.