Abstract
Enhancing the cold start performance of short stacks at low temperatures, which is largely attributed to their significant end-plate effect, proves essential for advancing commercialization. The constant current control strategy remains the most prevalent approach during startup operations. In this study, a 12-cell short stack was employed to investigate experimentally the effects of ambient temperatures and current load rates on cold start behavior. Results demonstrate that decreasing ambient temperatures intensifies the end-plate effect, while implementing lower current load rates effectively prolongs cold-start duration. At elevated ambient temperatures, the generated heat predominates over potential freezing risks for successful rapid startups. The current-controlled cold start process can be divided into three stages: initial performance recovery, moderate membrane water adsorption, and icing onset, which are primarily associated with the hydration state of the membrane electrode assembly. Variations in high frequency resistance evolution and reverse polarity characteristics emerge across these stages. Membrane electrode assembly damage induced by reverse polarity and icing leads to substantial increases in both high frequency resistance and membrane resistance, accompanied by a marginal reduction in the roughness factor of catalyst layer. The protective voltage strategy sustains stable stack performance, demonstrating high consistency at −10 °C. However, significant performance degradation manifests below −20 °C, particularly near end-plates, emphasizing the critical requirement for maintaining internal thermal uniformity under extreme low-temperature conditions.
Suggested Citation
He, Pu & Zhang, Qianxi & Mu, Yutong & Qu, Zhiguo & Yin, Jinzhou & Li, Ziai & Yang, Weiwei & Cai, Saijie & Chen, Junhong & Tao, Wenquan, 2025.
"Experimental investigation on the impact of ambient temperature and current load rate on the cold start behavior of a short PEMFC stack,"
Applied Energy, Elsevier, vol. 396(C).
Handle:
RePEc:eee:appene:v:396:y:2025:i:c:s0306261925010475
DOI: 10.1016/j.apenergy.2025.126317
Download full text from publisher
As the access to this document is restricted, you may want to
for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:396:y:2025:i:c:s0306261925010475. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.