IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v12y2020i24p10288-d459286.html
   My bibliography  Save this article

Sensitivity Analysis of Envelope Design Parameters of Industrial Buildings with Natural Ventilation

Author

Listed:
  • Xiaojing Meng

    (School of Resources Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
    State Key Laboratory of Green Building in Western China, Xi’an University of Architecture and Technology, Xi’an 710055, China)

  • Beibei Wei

    (State Key Laboratory of Green Building in Western China, Xi’an University of Architecture and Technology, Xi’an 710055, China)

  • Yingni Zhai

    (State Key Laboratory of Green Building in Western China, Xi’an University of Architecture and Technology, Xi’an 710055, China
    School of Mechanical and Electrical Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China)

Abstract

It is beneficial for designers to identify the most important design parameters of building envelopes. This study undertook sensitivity analysis integrated with EnergyPlus to assess the impacts of envelope design parameters for naturally ventilated industrial buildings. Sensitivity coefficients of six envelope design parameters for different internal heat intensities were analyzed and compared for buildings in the city of Xi’an, located in the cold climate zone of China. Our results showed that the heat transfer coefficient of the roofs had the most significant impact on indoor temperature. The weights were 32.29%, 33.71% and 30.71%, and the heat intensities were 5, 10 and 15 W/m 3 , respectively. The effect of the skylight-to-roof ratio was the second most sensitive. The impact of the solar absorptances of the walls and roof on the total number of hours was not sensitive. The results could be helpful for designers to efficiently form alternative design solutions in the design of new and retrofitting industrial buildings.

Suggested Citation

  • Xiaojing Meng & Beibei Wei & Yingni Zhai, 2020. "Sensitivity Analysis of Envelope Design Parameters of Industrial Buildings with Natural Ventilation," Sustainability, MDPI, vol. 12(24), pages 1-12, December.
  • Handle: RePEc:gam:jsusta:v:12:y:2020:i:24:p:10288-:d:459286
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/12/24/10288/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/12/24/10288/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Ucar, Aynur, 2010. "Thermoeconomic analysis method for optimization of insulation thickness for the four different climatic regions of Turkey," Energy, Elsevier, vol. 35(4), pages 1854-1864.
    2. A.M. Fogheri, 2015. "Energy Efficiency in Public Buildings," Rivista economica del Mezzogiorno, Società editrice il Mulino, issue 3-4, pages 763-784.
    3. Heiselberg, Per & Brohus, Henrik & Hesselholt, Allan & Rasmussen, Henrik & Seinre, Erkki & Thomas, Sara, 2009. "Application of sensitivity analysis in design of sustainable buildings," Renewable Energy, Elsevier, vol. 34(9), pages 2030-2036.
    4. Gourlis, Georgios & Kovacic, Iva, 2017. "Passive measures for preventing summer overheating in industrial buildings under consideration of varying manufacturing process loads," Energy, Elsevier, vol. 137(C), pages 1175-1185.
    5. Xiaolong Xu & Guohui Feng & Dandan Chi & Ming Liu & Baoyue Dou, 2018. "Optimization of Performance Parameter Design and Energy Use Prediction for Nearly Zero Energy Buildings," Energies, MDPI, vol. 11(12), pages 1-23, November.
    6. Gourlis, Georgios & Kovacic, Iva, 2016. "A study on building performance analysis for energy retrofit of existing industrial facilities," Applied Energy, Elsevier, vol. 184(C), pages 1389-1399.
    7. Brinks, Pascal & Kornadt, Oliver & Oly, René, 2016. "Development of concepts for cost-optimal nearly zero-energy buildings for the industrial steel building sector," Applied Energy, Elsevier, vol. 173(C), pages 343-354.
    8. Chow, W. K. & Chan, K. T., 1995. "Parameterization study of the overall thermal-transfer value equation for buildings," Applied Energy, Elsevier, vol. 50(3), pages 247-268.
    9. Jozef Švajlenka & Mária Kozlovská & Terézia Pošiváková, 2018. "Analysis of Selected Building Constructions Used in Industrial Construction in Terms of Sustainability Benefits," Sustainability, MDPI, vol. 10(12), pages 1-16, November.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Sara Elhadad & Zoltan Orban, 2021. "A Sensitivity Analysis for Thermal Performance of Building Envelope Design Parameters," Sustainability, MDPI, vol. 13(24), pages 1-17, December.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Wenxiao Chu & Francesco Calise & Neven Duić & Poul Alberg Østergaard & Maria Vicidomini & Qiuwang Wang, 2020. "Recent Advances in Technology, Strategy and Application of Sustainable Energy Systems," Energies, MDPI, vol. 13(19), pages 1-29, October.
    2. Marco Noro & Simone Mancin & Filippo Busato & Francesco Cerboni, 2023. "Innovative Hybrid Condensing Radiant System for Industrial Heating: An Energy and Economic Analysis," Sustainability, MDPI, vol. 15(4), pages 1-20, February.
    3. Carlos A. Espino-Reyes & Naghelli Ortega-Avila & Norma A. Rodriguez-Muñoz, 2020. "Energy Savings on an Industrial Building in Different Climate Zones: Envelope Analysis and PV System Implementation," Sustainability, MDPI, vol. 12(4), pages 1-22, February.
    4. Gourlis, Georgios & Kovacic, Iva, 2017. "Passive measures for preventing summer overheating in industrial buildings under consideration of varying manufacturing process loads," Energy, Elsevier, vol. 137(C), pages 1175-1185.
    5. Huang, He & Wang, Honglei & Hu, Yu-Jie & Li, Chengjiang & Wang, Xiaolin, 2022. "Optimal plan for energy conservation and CO2 emissions reduction of public buildings considering users' behavior: Case of China," Energy, Elsevier, vol. 261(PA).
    6. Østergård, Torben & Jensen, Rasmus L. & Maagaard, Steffen E., 2016. "Building simulations supporting decision making in early design – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 61(C), pages 187-201.
    7. Guzović, Zvonimir & Duic, Neven & Piacentino, Antonio & Markovska, Natasa & Mathiesen, Brian Vad & Lund, Henrik, 2022. "Recent advances in methods, policies and technologies at sustainable energy systems development," Energy, Elsevier, vol. 245(C).
    8. Yu Dong & Tongyu Qin & Siyuan Zhou & Lu Huang & Rui Bo & Haibo Guo & Xunzhi Yin, 2020. "Comparative Whole Building Life Cycle Assessment of Energy Saving and Carbon Reduction Performance of Reinforced Concrete and Timber Stadiums—A Case Study in China," Sustainability, MDPI, vol. 12(4), pages 1-24, February.
    9. Burek, Jasmina & Nutter, Darin W., 2019. "A life cycle assessment-based multi-objective optimization of the purchased, solar, and wind energy for the grocery, perishables, and general merchandise multi-facility distribution center network," Applied Energy, Elsevier, vol. 235(C), pages 1427-1446.
    10. Julia Reisinger & Patrick Hollinsky & Iva Kovacic, 2021. "Design Guideline for Flexible Industrial Buildings Integrating Industry 4.0 Parameters," Sustainability, MDPI, vol. 13(19), pages 1-24, September.
    11. Khencha Khadidja & Biara Ratiba Wided & Belmili Hocine, 2020. "Techno-economic study of BIPV in typical Sahara region in Algeria," Journal of Economic Development, Environment and People, Alliance of Central-Eastern European Universities, vol. 9(1), pages 27-57, September.
    12. Leurent, Martin & Jasserand, Frédéric & Locatelli, Giorgio & Palm, Jenny & Rämä, Miika & Trianni, Andrea, 2017. "Driving forces and obstacles to nuclear cogeneration in Europe: Lessons learnt from Finland," Energy Policy, Elsevier, vol. 107(C), pages 138-150.
    13. Yu, Jinghua & Ye, Hong & Xu, Xinhua & Huang, Junchao & Liu, Yunxi & Wang, Jinbo, 2018. "Experimental study on the thermal performance of a hollow block ventilation wall," Renewable Energy, Elsevier, vol. 122(C), pages 619-631.
    14. Solène Goy & François Maréchal & Donal Finn, 2020. "Data for Urban Scale Building Energy Modelling: Assessing Impacts and Overcoming Availability Challenges," Energies, MDPI, vol. 13(16), pages 1-23, August.
    15. Tian, Wei & Song, Jitian & Li, Zhanyong & de Wilde, Pieter, 2014. "Bootstrap techniques for sensitivity analysis and model selection in building thermal performance analysis," Applied Energy, Elsevier, vol. 135(C), pages 320-328.
    16. Wang, Y. & Mauree, D. & Sun, Q. & Lin, H. & Scartezzini, J.L. & Wennersten, R., 2020. "A review of approaches to low-carbon transition of high-rise residential buildings in China," Renewable and Sustainable Energy Reviews, Elsevier, vol. 131(C).
    17. Yu, Philip C.H. & Chow, W.K., 2001. "Energy use in commercial buildings in Hong Kong," Applied Energy, Elsevier, vol. 69(4), pages 243-255, August.
    18. Liang Zhao & Wei Zhang & Wenshun Wang, 2022. "BIM-Based Multi-Objective Optimization of Low-Carbon and Energy-Saving Buildings," Sustainability, MDPI, vol. 14(20), pages 1-17, October.
    19. Axaopoulos, Ioannis & Axaopoulos, Petros & Gelegenis, John, 2014. "Optimum insulation thickness for external walls on different orientations considering the speed and direction of the wind," Applied Energy, Elsevier, vol. 117(C), pages 167-175.
    20. Tong, Zheming & Chen, Yujiao & Malkawi, Ali & Liu, Zhu & Freeman, Richard B., 2016. "Energy saving potential of natural ventilation in China: The impact of ambient air pollution," Applied Energy, Elsevier, vol. 179(C), pages 660-668.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:12:y:2020:i:24:p:10288-:d:459286. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.