Liquid-filled glazing with submerged heat exchanger is a kind of building integrated solar thermal collector making full use of the transparent façade surface. This novel glazing is capable of preheating domestic water and reducing heat transmission to the indoor space, thus contributes to energy saving of the hot water system and the air-conditioning system. Dynamic thermal model of the glazing system has been developed by assuming uniform temperature and cellular flow in the window cavity. In this study, CFD analysis was employed to verify the assumed liquid flow pattern and temperature distribution. Then parametric study was carried out to assess the impact of several key influencing factors, including glass material, feed water flow rate, and cavity thickness on the thermal performance. The investigation supported an appropriate cavity thickness of 10 mm and feed water flow rate of 1000 ml/min per m2 glazed surface area for effective thermal performance. The use of two absorptive glass panes in the double-glazing gives the best thermal efficiency and electricity saving. The thermal performance of this new design was also compared with the buoyant-flow window design based on typical summer and winter conditions of Hong Kong. The results indicate its superiority and significance in green building development.

Suggested Citation

  • Liu, Wenjie & Chow, Tin-tai, 2021. "Performance analysis of liquid-flow-window with submerged heat exchanger," Renewable Energy, Elsevier, vol. 168(C), pages 319-331.
  • Handle: RePEc:eee:renene:v:168:y:2021:i:c:p:319-331
    DOI: 10.1016/j.renene.2020.12.067
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148120320073
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2020.12.067?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Liu, Dingming & Sun, Yanyi & Wilson, Robin & Wu, Yupeng, 2020. "Comprehensive evaluation of window-integrated semi-transparent PV for building daylight performance," Renewable Energy, Elsevier, vol. 145(C), pages 1399-1411.
    2. Lyu, Yuanli & Liu, Wenjie & Chow, Tin-tai & Su, Hua & Qi, Xuejun, 2019. "Pipe-work optimization of water flow window," Renewable Energy, Elsevier, vol. 139(C), pages 136-146.
    3. Cuce, Erdem, 2016. "Toward multi-functional PV glazing technologies in low/zero carbon buildings: Heat insulation solar glass – Latest developments and future prospects," Renewable and Sustainable Energy Reviews, Elsevier, vol. 60(C), pages 1286-1301.
    4. Agathokleous, Rafaela A. & Kalogirou, Soteris A., 2016. "Double skin facades (DSF) and building integrated photovoltaics (BIPV): A review of configurations and heat transfer characteristics," Renewable Energy, Elsevier, vol. 89(C), pages 743-756.
    5. Li, Chunying & Tang, Haida, 2020. "Evaluation on year-round performance of double-circulation water-flow window," Renewable Energy, Elsevier, vol. 150(C), pages 176-190.
    6. Arıcı, Müslüm & Kan, Miraç, 2015. "An investigation of flow and conjugate heat transfer in multiple pane windows with respect to gap width, emissivity and gas filling," Renewable Energy, Elsevier, vol. 75(C), pages 249-256.
    7. Casini, Marco, 2018. "Active dynamic windows for buildings: A review," Renewable Energy, Elsevier, vol. 119(C), pages 923-934.
    8. Fang, Yueping & Memon, Saim & Peng, Jingqing & Tyrer, Mark & Ming, Tingzhen, 2020. "Solar thermal performance of two innovative configurations of air-vacuum layered triple glazed windows," Renewable Energy, Elsevier, vol. 150(C), pages 167-175.
    9. Nourozi, Behrouz & Ploskić, Adnan & Chen, Yuxiang & Ning-Wei Chiu, Justin & Wang, Qian, 2020. "Heat transfer model for energy-active windows – An evaluation of efficient reuse of waste heat in buildings," Renewable Energy, Elsevier, vol. 162(C), pages 2318-2329.
    10. Miyazaki, T. & Akisawa, A. & Kashiwagi, T., 2005. "Energy savings of office buildings by the use of semi-transparent solar cells for windows," Renewable Energy, Elsevier, vol. 30(3), pages 281-304.
    11. Gil-Lopez, Tomas & Gimenez-Molina, Carmen, 2013. "Environmental, economic and energy analysis of double glazing with a circulating water chamber in residential buildings," Applied Energy, Elsevier, vol. 101(C), pages 572-581.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Ghosh, Aritra & Norton, Brian, 2018. "Advances in switchable and highly insulating autonomous (self-powered) glazing systems for adaptive low energy buildings," Renewable Energy, Elsevier, vol. 126(C), pages 1003-1031.
    2. Luo, Yongqiang & Zhang, Ling & Liu, Zhongbing & Xie, Lei & Wang, Xiliang & Wu, Jing, 2018. "Experimental study and performance evaluation of a PV-blind embedded double skin façade in winter season," Energy, Elsevier, vol. 165(PB), pages 326-342.
    3. Uddin, Md Muin & Wang, Chuyao & Zhang, Chengyan & Ji, Jie, 2022. "Investigating the energy-saving performance of a CdTe-based semi-transparent photovoltaic combined hybrid vacuum glazing window system," Energy, Elsevier, vol. 253(C).
    4. Shen, Yi & Xue, Peng & Luo, Tao & Zhang, Yanyun & Tso, Chi Yan & Zhang, Nan & Sun, Yuying & Xie, Jingchao & Liu, Jiaping, 2022. "Regional applicability of thermochromic windows based on dynamic radiation spectrum," Renewable Energy, Elsevier, vol. 196(C), pages 15-27.
    5. Mesloub, Abdelhakim & Ghosh, Aritra & Touahmia, Mabrouk & Albaqawy, Ghazy Abdullah & Alsolami, Badr M. & Ahriz, Atef, 2022. "Assessment of the overall energy performance of an SPD smart window in a hot desert climate," Energy, Elsevier, vol. 252(C).
    6. Yu, Guoqing & Yang, Hongxing & Luo, Daina & Cheng, Xu & Ansah, Mark Kyeredey, 2021. "A review on developments and researches of building integrated photovoltaic (BIPV) windows and shading blinds," Renewable and Sustainable Energy Reviews, Elsevier, vol. 149(C).
    7. Borys Basok & Borys Davydenko & Volodymyr Novikov & Anatoliy M. Pavlenko & Maryna Novitska & Karolina Sadko & Svitlana Goncharuk, 2022. "Evaluation of Heat Transfer Rates through Transparent Dividing Structures," Energies, MDPI, vol. 15(13), pages 1-16, July.
    8. Zhang, Tiantian & Tan, Yufei & Yang, Hongxing & Zhang, Xuedan, 2016. "The application of air layers in building envelopes: A review," Applied Energy, Elsevier, vol. 165(C), pages 707-734.
    9. Lyu, Yuanli & Liu, Wenjie & Chow, Tin-tai & Su, Hua & Qi, Xuejun, 2019. "Pipe-work optimization of water flow window," Renewable Energy, Elsevier, vol. 139(C), pages 136-146.
    10. Vassiliades, C. & Agathokleous, R. & Barone, G. & Forzano, C. & Giuzio, G.F. & Palombo, A. & Buonomano, A. & Kalogirou, S., 2022. "Building integration of active solar energy systems: A review of geometrical and architectural characteristics," Renewable and Sustainable Energy Reviews, Elsevier, vol. 164(C).
    11. Chan, Lok Shun, 2023. "Numerical study on the thermal performance of water flow window fed with air-conditioning condensate," Energy, Elsevier, vol. 263(PB).
    12. Nourozi, Behrouz & Ploskić, Adnan & Chen, Yuxiang & Ning-Wei Chiu, Justin & Wang, Qian, 2020. "Heat transfer model for energy-active windows – An evaluation of efficient reuse of waste heat in buildings," Renewable Energy, Elsevier, vol. 162(C), pages 2318-2329.
    13. Luo, Yongqiang & Zhang, Ling & Bozlar, Michael & Liu, Zhongbing & Guo, Hongshan & Meggers, Forrest, 2019. "Active building envelope systems toward renewable and sustainable energy," Renewable and Sustainable Energy Reviews, Elsevier, vol. 104(C), pages 470-491.
    14. Luo, Yongqiang & Zhang, Ling & Liu, Zhongbing & Su, Xiaosong & Lian, Jinbu & Luo, Yongwei, 2018. "Coupled thermal-electrical-optical analysis of a photovoltaic-blind integrated glazing façade," Applied Energy, Elsevier, vol. 228(C), pages 1870-1886.
    15. Wang, Chuyao & Li, Niansi & Gu, Tao & Ji, Jie & Yu, Bendong, 2022. "Design and performance investigation of a novel double-skin ventilated window integrated with air-purifying blind," Energy, Elsevier, vol. 254(PC).
    16. Wu, Zhenghong & Zhang, Ling & Wu, Jing & Liu, Zhongbing, 2022. "Experimental and numerical study on the annual performance of semi-transparent photovoltaic glazing in different climate zones," Energy, Elsevier, vol. 240(C).
    17. Mir M. Ali & Kheir Al-Kodmany & Paul J. Armstrong, 2023. "Energy Efficiency of Tall Buildings: A Global Snapshot of Innovative Design," Energies, MDPI, vol. 16(4), pages 1-23, February.
    18. Michaux, Ghislain & Greffet, Rémy & Salagnac, Patrick & Ridoret, Jean-Baptiste, 2019. "Modelling of an airflow window and numerical investigation of its thermal performances by comparison to conventional double and triple-glazed windows," Applied Energy, Elsevier, vol. 242(C), pages 27-45.
    19. Li, Danny H.W. & Lam, Tony N.T. & Chan, Wilco W.H. & Mak, Ada H.L., 2009. "Energy and cost analysis of semi-transparent photovoltaic in office buildings," Applied Energy, Elsevier, vol. 86(5), pages 722-729, May.
    20. Belen Moreno Santamaria & Fernando del Ama Gonzalo & Benito Lauret Aguirregabiria & Juan A. Hernandez Ramos, 2020. "Experimental Validation of Water Flow Glazing: Transient Response in Real Test Rooms," Sustainability, MDPI, vol. 12(14), pages 1-24, July.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:168:y:2021:i:c:p:319-331. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.