In general, the glazed façade area of a building is the part that produces the greatest energy losses and gains. The basic aim of this work is to achieve a more efficient heat control in closed spaces. To this end, an exhaustive study has been made of active glazing comprising two laminated glass panels with a circulating water chamber. Not only has the energy consumption been analysed but also the energy efficiency according to fuel type, the amount of CO2 emitted into the atmosphere and the economic cost. The results of this study, from the points of view of economic feasibility and energy efficiency, show that the solution of double glazing with a circulating water chamber is a less polluting and more efficient option than the systems currently used. This solution is able to reduce the energy losses and gains that are produced through the glazed façade of a building by 18.26% for calorific and frigorific energy compared to the total consumption of the building. The layout of the proposed installation facilitates its integration into any type of residential building, either under construction or being renovated. Moreover, its zero visual impact means it can even be implemented in places with strict town-planning regulations.

Suggested Citation

  • Gil-Lopez, Tomas & Gimenez-Molina, Carmen, 2013. "Environmental, economic and energy analysis of double glazing with a circulating water chamber in residential buildings," Applied Energy, Elsevier, vol. 101(C), pages 572-581.
  • Handle: RePEc:eee:appene:v:101:y:2013:i:c:p:572-581
    DOI: 10.1016/j.apenergy.2012.06.055
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306261912005004
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.apenergy.2012.06.055?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Buratti, C. & Moretti, E., 2012. "Glazing systems with silica aerogel for energy savings in buildings," Applied Energy, Elsevier, vol. 98(C), pages 396-403.
    2. Buratti, C. & Moretti, E., 2012. "Experimental performance evaluation of aerogel glazing systems," Applied Energy, Elsevier, vol. 97(C), pages 430-437.
    3. Han, Jun & Lu, Lin & Yang, Hongxing, 2010. "Numerical evaluation of the mixed convective heat transfer in a double-pane window integrated with see-through a-Si PV cells with low-e coatings," Applied Energy, Elsevier, vol. 87(11), pages 3431-3437, November.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Lyu, Yuan-Li & Chow, Tin-Tai & Wang, Jin-Liang, 2018. "Numerical prediction of thermal performance of liquid-flow window in different climates with anti-freeze," Energy, Elsevier, vol. 157(C), pages 412-423.
    2. Ghosh, Aritra & Norton, Brian, 2018. "Advances in switchable and highly insulating autonomous (self-powered) glazing systems for adaptive low energy buildings," Renewable Energy, Elsevier, vol. 126(C), pages 1003-1031.
    3. Patricia Aguilera-Benito & Sheila Varela-Lujan & Carolina Piña-Ramirez, 2021. "Thermal Behavior in Glass Houses through the Analysis of Scale Models," Sustainability, MDPI, vol. 13(14), pages 1-17, July.
    4. Belen Moreno Santamaria & Fernando del Ama Gonzalo & Benito Lauret Aguirregabiria & Juan A. Hernandez Ramos, 2020. "Experimental Validation of Water Flow Glazing: Transient Response in Real Test Rooms," Sustainability, MDPI, vol. 12(14), pages 1-24, July.
    5. Belen Moreno Santamaria & Fernando del Ama Gonzalo & Benito Lauret Aguirregabiria & Juan A. Hernandez Ramos, 2020. "Evaluation of Thermal Comfort and Energy Consumption of Water Flow Glazing as a Radiant Heating and Cooling System: A Case Study of an Office Space," Sustainability, MDPI, vol. 12(18), pages 1-27, September.
    6. Yang, Liu & Yan, Haiyan & Lam, Joseph C., 2014. "Thermal comfort and building energy consumption implications – A review," Applied Energy, Elsevier, vol. 115(C), pages 164-173.
    7. Lyu, Yuanli & Liu, Wenjie & Chow, Tin-tai & Su, Hua & Qi, Xuejun, 2019. "Pipe-work optimization of water flow window," Renewable Energy, Elsevier, vol. 139(C), pages 136-146.
    8. Gil-Lopez, Tomas & Sanchez-Sanchez, Agustin & Gimenez-Molina, Carmen, 2014. "Energy, environmental and economic analysis of the ventilation system of enclosed parking garages: Discrepancies with the current regulations," Applied Energy, Elsevier, vol. 113(C), pages 622-630.
    9. Liu, Wenjie & Chow, Tin-tai, 2021. "Performance analysis of liquid-flow-window with submerged heat exchanger," Renewable Energy, Elsevier, vol. 168(C), pages 319-331.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Cuce, Erdem & Riffat, Saffa B., 2015. "A state-of-the-art review on innovative glazing technologies," Renewable and Sustainable Energy Reviews, Elsevier, vol. 41(C), pages 695-714.
    2. Ghosh, Aritra & Norton, Brian, 2018. "Advances in switchable and highly insulating autonomous (self-powered) glazing systems for adaptive low energy buildings," Renewable Energy, Elsevier, vol. 126(C), pages 1003-1031.
    3. Ghosh, Aritra & Norton, Brian & Duffy, Aidan, 2016. "Measured thermal performance of a combined suspended particle switchable device evacuated glazing," Applied Energy, Elsevier, vol. 169(C), pages 469-480.
    4. Zhou, Yuekuan & Zheng, Siqian, 2020. "Uncertainty study on thermal and energy performances of a deterministic parameters based optimal aerogel glazing system using machine-learning method," Energy, Elsevier, vol. 193(C).
    5. Ghosh, Aritra & Norton, Brian & Duffy, Aidan, 2017. "Effect of sky clearness index on transmission of evacuated (vacuum) glazing," Renewable Energy, Elsevier, vol. 105(C), pages 160-166.
    6. Lin, Yi-Feng & Ko, Chia-Chieh & Chen, Chien-Hua & Tung, Kuo-Lun & Chang, Kai-Shiun & Chung, Tsair-Wang, 2014. "Sol–gel preparation of polymethylsilsesquioxane aerogel membranes for CO2 absorption fluxes in membrane contactors," Applied Energy, Elsevier, vol. 129(C), pages 25-31.
    7. Zhou, Yuekuan & Zheng, Siqian, 2020. "Climate adaptive optimal design of an aerogel glazing system with the integration of a heuristic teaching-learning-based algorithm in machine learning-based optimization," Renewable Energy, Elsevier, vol. 153(C), pages 375-391.
    8. Hee, W.J. & Alghoul, M.A. & Bakhtyar, B. & Elayeb, OmKalthum & Shameri, M.A. & Alrubaih, M.S. & Sopian, K., 2015. "The role of window glazing on daylighting and energy saving in buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 42(C), pages 323-343.
    9. Cuce, Erdem & Cuce, Pinar Mert & Wood, Christopher J. & Riffat, Saffa B., 2014. "Toward aerogel based thermal superinsulation in buildings: A comprehensive review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 34(C), pages 273-299.
    10. Ricciardi, P. & Belloni, E. & Cotana, F., 2014. "Innovative panels with recycled materials: Thermal and acoustic performance and Life Cycle Assessment," Applied Energy, Elsevier, vol. 134(C), pages 150-162.
    11. Ibrahim, Mohamad & Biwole, Pascal Henry & Achard, Patrick & Wurtz, Etienne & Ansart, Guillaume, 2015. "Building envelope with a new aerogel-based insulating rendering: Experimental and numerical study, cost analysis, and thickness optimization," Applied Energy, Elsevier, vol. 159(C), pages 490-501.
    12. Lin, Yi-Feng & Chang, Jun-Min & Ye, Qian & Tung, Kuo-Lun, 2015. "Hydrophobic fluorocarbon-modified silica aerogel tubular membranes with excellent CO2 recovery ability in membrane contactors," Applied Energy, Elsevier, vol. 154(C), pages 21-25.
    13. Sun, Yanyi & Wilson, Robin & Wu, Yupeng, 2018. "A Review of Transparent Insulation Material (TIM) for building energy saving and daylight comfort," Applied Energy, Elsevier, vol. 226(C), pages 713-729.
    14. Baldinelli, G. & Bianchi, F., 2014. "Windows thermal resistance: Infrared thermography aided comparative analysis among finite volumes simulations and experimental methods," Applied Energy, Elsevier, vol. 136(C), pages 250-258.
    15. Cuce, Erdem & Harjunowibowo, Dewanto & Cuce, Pinar Mert, 2016. "Renewable and sustainable energy saving strategies for greenhouse systems: A comprehensive review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 64(C), pages 34-59.
    16. Elisa Moretti & Emanuele Bonamente & Cinzia Buratti & Franco Cotana, 2013. "Development of Innovative Heating and Cooling Systems Using Renewable Energy Sources for Non-Residential Buildings," Energies, MDPI, vol. 6(10), pages 1-16, October.
    17. Cinzia Buratti & Elisa Lascaro & Domenico Palladino & Marco Vergoni, 2014. "Building Behavior Simulation by Means of Artificial Neural Network in Summer Conditions," Sustainability, MDPI, vol. 6(8), pages 1-15, August.
    18. Zhou, Yuekuan & Zheng, Siqian, 2020. "Stochastic uncertainty-based optimisation on an aerogel glazing building in China using supervised learning surrogate model and a heuristic optimisation algorithm," Renewable Energy, Elsevier, vol. 155(C), pages 810-826.
    19. Kong, Yong & Shen, Xiaodong & Cui, Sheng & Fan, Maohong, 2015. "Development of monolithic adsorbent via polymeric sol–gel process for low-concentration CO2 capture," Applied Energy, Elsevier, vol. 147(C), pages 308-317.
    20. Liu, Yang & Chen, Youming & Lu, Lin & Peng, Jinqing & Zheng, Dongmei & Lu, Bin, 2023. "Optical path model and energy performance optimization of aerogel glazing system filled with aerogel granules," Applied Energy, Elsevier, vol. 334(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:101:y:2013:i:c:p:572-581. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.