IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v214y2021ics0360544220322052.html
   My bibliography  Save this article

Energy performance evaluation of two-phase injection heat pump employing low-GWP refrigerant R32 under various outdoor conditions

Author

Listed:
  • Kim, Dongwoo
  • Lee, DongChan
  • Lee, Minwoo
  • Chung, Hyun Joon
  • Kim, Yongchan

Abstract

The refrigerant R32 has been receiving significant attention as an alternative to R410A used in heat pumps, owing to its lower global warming potential. The two-phase injection (TPI) technique is introduced to achieve improved energy performance along with high system reliability in R32 heat pumps, owing to their high discharge temperature. The objectives of this study are to compare the performances as well as reliabilities of the R32 and R410A TPI heat pumps and provide the design guidelines for achieving the best performance with safe operation. The performances of the R32 and R410A TPI heat pumps are measured by varying compressor frequency and outdoor temperature. The TPI technique enables the R32 heat pump to operate at a higher compressor frequency under severe weather conditions. At low outdoor temperatures of −10 °C and −15 °C, the R32 TPI heat pump demonstrates a superior heating capacity and coefficient of performance (COP) compared with the R410A TPI heat pump. In addition, the injection parameters in the R32 TPI heat pump are optimized under various operating conditions.

Suggested Citation

  • Kim, Dongwoo & Lee, DongChan & Lee, Minwoo & Chung, Hyun Joon & Kim, Yongchan, 2021. "Energy performance evaluation of two-phase injection heat pump employing low-GWP refrigerant R32 under various outdoor conditions," Energy, Elsevier, vol. 214(C).
  • Handle: RePEc:eee:energy:v:214:y:2021:i:c:s0360544220322052
    DOI: 10.1016/j.energy.2020.119098
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544220322052
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2020.119098?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Kim, Dongwoo & Song, Kang Sub & Lim, Junyub & Kim, Yongchan, 2018. "Analysis of two-phase injection heat pump using artificial neural network considering APF and LCCP under various weather conditions," Energy, Elsevier, vol. 155(C), pages 117-127.
    2. Cho, Il Yong & Seo, HyeongJoon & Kim, Dongwoo & Kim, Yongchan, 2016. "Performance comparison between R410A and R32 multi-heat pumps with a sub-cooler vapor injection in the heating and cooling modes," Energy, Elsevier, vol. 112(C), pages 179-187.
    3. Qv, Dehu & Dong, Bingbing & Cao, Lin & Ni, Long & Wang, Jijin & Shang, Runxin & Yao, Yang, 2017. "An experimental and theoretical study on an injection-assisted air-conditioner using R32 in the refrigeration cycle," Applied Energy, Elsevier, vol. 185(P1), pages 791-804.
    4. Kim, Dongwoo & Myeong, Seongryeol & Cha, Dowon & Kim, Yongchan, 2019. "Novel optimized operating strategies of two-phase injection heat pumps for achieving best performance with safe compression," Energy, Elsevier, vol. 187(C).
    5. Mota-Babiloni, Adrián & Navarro-Esbrí, Joaquín & Makhnatch, Pavel & Molés, Francisco, 2017. "Refrigerant R32 as lower GWP working fluid in residential air conditioning systems in Europe and the USA," Renewable and Sustainable Energy Reviews, Elsevier, vol. 80(C), pages 1031-1042.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Maeng, Heegyu & Kim, Jinyoung & Kwon, Soonbum & Kim, Yongchan, 2023. "Energy and environmental performance of vapor injection heat pumps using R134a, R152a, and R1234yf under various injection conditions," Energy, Elsevier, vol. 280(C).

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Kim, Dongwoo & Myeong, Seongryeol & Cha, Dowon & Kim, Yongchan, 2019. "Novel optimized operating strategies of two-phase injection heat pumps for achieving best performance with safe compression," Energy, Elsevier, vol. 187(C).
    2. Kim, Dongwoo & Song, Kang Sub & Lim, Junyub & Kim, Yongchan, 2018. "Analysis of two-phase injection heat pump using artificial neural network considering APF and LCCP under various weather conditions," Energy, Elsevier, vol. 155(C), pages 117-127.
    3. Maeng, Heegyu & Kim, Jinyoung & Kwon, Soonbum & Kim, Yongchan, 2023. "Energy and environmental performance of vapor injection heat pumps using R134a, R152a, and R1234yf under various injection conditions," Energy, Elsevier, vol. 280(C).
    4. López-Belchí, Alejandro & Illán-Gómez, Fernando, 2017. "Evaluation of a condenser based on mini-channels technology working with R410A and R32. Experimental data and performance estimate," Applied Energy, Elsevier, vol. 202(C), pages 112-124.
    5. Jung, Jongho & Jeon, Yongseok & Cho, Wonhee & Kim, Yongchan, 2020. "Effects of injection-port angle and internal heat exchanger length in vapor injection heat pumps for electric vehicles," Energy, Elsevier, vol. 193(C).
    6. Yuan, Zhipeng & Liu, Qi & Luo, Baojun & Li, Zhenming & Fu, Jianqin & Chen, Jingwei, 2018. "Thermodynamic analysis of different oil flooded compression enhanced vapor injection cycles," Energy, Elsevier, vol. 154(C), pages 553-560.
    7. Shuxue, Xu & Yueyue, Wang & Jianhui, Niu & Guoyuan, Ma, 2020. "‘Coal-to-electricity’ project is ongoing in north China," Energy, Elsevier, vol. 191(C).
    8. Kim, Dongwoo & Yim, Taesu & Lee, Jae Yong, 2021. "Analytical study on changes in domestic hot water use caused by COVID-19 pandemic," Energy, Elsevier, vol. 231(C).
    9. Hui, Hongxun & Ding, Yi & Liu, Weidong & Lin, You & Song, Yonghua, 2017. "Operating reserve evaluation of aggregated air conditioners," Applied Energy, Elsevier, vol. 196(C), pages 218-228.
    10. Jeon, Yongseok & Kim, Sunjae & Lee, Sang Hun & Chung, Hyun Joon & Kim, Yongchan, 2020. "Seasonal energy performance characteristics of novel ejector-expansion air conditioners with low-GWP refrigerants," Applied Energy, Elsevier, vol. 278(C).
    11. Albà, C.G. & Alkhatib, I.I.I. & Llovell, F. & Vega, L.F., 2023. "Hunting sustainable refrigerants fulfilling technical, environmental, safety and economic requirements," Renewable and Sustainable Energy Reviews, Elsevier, vol. 188(C).
    12. Chung, Hyun Joon & Baek, Changhyun & Kang, Hoon & Kim, Dongwoo & Kim, Yongchan, 2018. "Performance evaluation of a gas injection CO2 heat pump according to operating parameters in extreme heating and cooling conditions," Energy, Elsevier, vol. 154(C), pages 337-345.
    13. Piyanut Saengsikhiao & Juntakan Taweekun & Kittinan Maliwan & Somchai Sae-ung & Thanansak Theppaya, 2020. "Investigation and Analysis of R463A as an Alternative Refrigerant to R404A with Lower Global Warming Potential," Energies, MDPI, vol. 13(6), pages 1-19, March.
    14. Meng, Fanxi & Zhang, Quan & Lin, Yaolin & Zou, Sikai & Fu, Jiyao & Liu, Baochang & Wang, Wei & Ma, Xiaowei & Du, Sheng, 2022. "Field study on the performance of a thermosyphon and mechanical refrigeration hybrid cooling system in a 5G telecommunication base station," Energy, Elsevier, vol. 252(C).
    15. Ana Fernández-Guillamón & Ángel Molina-García & Francisco Vera-García & José A. Almendros-Ibáñez, 2021. "Organic Rankine Cycle Optimization Performance Analysis Based on Super-Heater Pressure: Comparison of Working Fluids," Energies, MDPI, vol. 14(9), pages 1-16, April.
    16. Hongzhi Liu & Katsunori Nagano & Takao Katsura & Yue Han, 2020. "Experimental Investigation on a Vapor Injection Heat Pump System with a Single-Stage Compressor," Energies, MDPI, vol. 13(12), pages 1-19, June.
    17. Chugh, Devesh & Gluesenkamp, Kyle & Abdelaziz, Omar & Moghaddam, Saeed, 2017. "Ionic liquid-based hybrid absorption cycle for water heating, dehumidification, and cooling," Applied Energy, Elsevier, vol. 202(C), pages 746-754.
    18. Sergio Bobbo & Laura Fedele & Marco Curcio & Anna Bet & Michele De Carli & Giuseppe Emmi & Fabio Poletto & Andrea Tarabotti & Dimitris Mendrinos & Giulia Mezzasalma & Adriana Bernardi, 2019. "Energetic and Exergetic Analysis of Low Global Warming Potential Refrigerants as Substitutes for R410A in Ground Source Heat Pumps," Energies, MDPI, vol. 12(18), pages 1-16, September.
    19. Song, Zhiying & Ji, Jie & Zhang, Yuzhe & Cai, Jingyong, 2023. "Numerical exploration and experimental validation of a tri-generation heat pump system in cooling mode," Energy, Elsevier, vol. 273(C).
    20. Fan, Yi & Zhao, Xudong & Li, Jing & Li, Guiqiang & Myers, Steve & Cheng, Yuanda & Badiei, Ali & Yu, Min & Golizadeh Akhlaghi, Yousef & Shittu, Samson & Ma, Xiaoli, 2020. "Economic and environmental analysis of a novel rural house heating and cooling system using a solar-assisted vapour injection heat pump," Applied Energy, Elsevier, vol. 275(C).

    More about this item

    Keywords

    Two-phase injection heat pump; R32; R410A; Energy performance; Reliability;
    All these keywords.

    JEL classification:

    • R32 - Urban, Rural, Regional, Real Estate, and Transportation Economics - - Real Estate Markets, Spatial Production Analysis, and Firm Location - - - Other Spatial Production and Pricing Analysis

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:214:y:2021:i:c:s0360544220322052. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.