IDEAS home Printed from https://ideas.repec.org/p/sek/iacpro/9811816.html
   My bibliography  Save this paper

Unconstrained Apnea Detection System Utilizing Compressed Time-Frequency Distribution by an Autoencoder

Author

Listed:
  • Misaki Kohama

    (Aoyama Gakuin University)

  • Keita Nisio

    (Aoyama Gakuin University)

  • Ikuya Takao

    (Aoyama Gakuin University)

  • Takashi Kaburagi

    (International Chirstian University)

  • Toshiyuki Matsumoto

    (Aoyama Gakuin University)

  • Satoshi Kumagai

    (Aoyama Gakuin University)

  • Yosuke Kurihara

    (Aoyama Gakuin University)

Abstract

Currently, ischemic heart disease is the most common cause of death worldwide, with 9.48 million people dying of the disease. More than 30% of ischemic heart disease patients have sleep apnea syndrome. Since it is difficult to detect whether a patient has sleep apnea syndrome; the consultation rate remains at 15%. Hence, routine monitoring is necessary to identify suspected patients. Many kinds of research on apnea detection have been conducted so far. The authors have also proposed a pneumatic method to measure a respiration signal unconstrainedly. In this study, we propose an unconstrained system to detect each occurrence of an apnea event by applying an autoencoder with two layers to the respiration signal. In the proposed method, we measure a signal from a pressure sensor placed under a mattress on which a person is lying. To obtain the respiration signal, a digital band-pass filter with cut-off frequencies ranging from 0.15 to 0.45 Hz is applied to the output signal from the pressure sensor. Wavelet transform is applied to the filtered respiration signal to obtain time-frequency distributions that represent frequencies characteristic for each time step. Then, the time-frequency characteristic sends inputs to an autoencoder with two layers and the dimensions of the time-frequency distribution is compressed. The proposed method consists of two phases: a training phase and a detection phase. In the training phase, the compressed data with supervised data that is expressed as 0 or 1(0: respiration, 1: apnea) is used to train a classification model including softmax function. In the detection phase, to detect an apnea event, the compressed data without supervised data is applied to the trained classification model.In the verification experiment, we prepared five subjects with variations in height and weight and acquired each subject?s data in four recumbent positions. Data obtained was a total of 20 (five subjects×four recumbent positions). The dimension of time-frequency distribution was set to 113. In the first layer, the dimension was compressed to 75 dimensions; and in the second layer, 75 dimensions were compressed to 50. The performance of the proposed method is evaluated by the leave-one-subject-out and leave-one-recumbent-position-out cross-validations. Based on results of cross-validations on all 20 data, the average correct answer rate was 0.90 for both the subjects and the recumbent positions. These results demonstrate that the proposed system was not susceptible to the subject and the recumbent position.

Suggested Citation

  • Misaki Kohama & Keita Nisio & Ikuya Takao & Takashi Kaburagi & Toshiyuki Matsumoto & Satoshi Kumagai & Yosuke Kurihara, 2019. "Unconstrained Apnea Detection System Utilizing Compressed Time-Frequency Distribution by an Autoencoder," Proceedings of International Academic Conferences 9811816, International Institute of Social and Economic Sciences.
  • Handle: RePEc:sek:iacpro:9811816
    as

    Download full text from publisher

    File URL: https://iises.net/proceedings/iises-international-academic-conference-dubrovnik/table-of-content/detail?cid=98&iid=023&rid=11816
    File Function: First version, 2019
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    sleep apnea; time-frequency distribution; autoencoder; wavelet transform;
    All these keywords.

    JEL classification:

    • I19 - Health, Education, and Welfare - - Health - - - Other

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:sek:iacpro:9811816. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Klara Cermakova (email available below). General contact details of provider: https://iises.net/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.