IDEAS home Printed from https://ideas.repec.org/p/sek/iacpro/10012462.html
   My bibliography  Save this paper

Automatic Control of a Room Ventilation System by a Single Fan Actuator

Author

Listed:
  • Tomomasa Yamasaki

    (Aoyama Gakuin University)

  • Takashi Kaburagi

    (International Christian University)

  • Toshiyuki Matsumoto

    (Aoyama Gakuin University)

  • Satoshi Kumagai

    (Aoyama Gakuin University)

  • Yosuke Kurihara

    (Aoyama Gakuin University)

  • Yosuke Kurihara

    (Aoyama Gakuin University)

Abstract

Ventilation with a combination of active aeration fans and passive openings is essential for keeping rooms in houses comfortable. However, excessive use of an exhaust fan may prevent doors from being opened because of decreasing pressure in the room. In addition, when the room pressure is too low, the aeration fans are not always able to ventilate the air. In this study, we present a simple feedback system to address these house ventilation problems. The proposed system uses a ventilation fan as an actuator and a highly sensitive sensor for feedback.The ventilation fan in the proposed system rests in standstill mode without any electric power supply. The fan starts rotating when the pressure difference between the inside and outside of the fan exceeds a specific value, and the basket-type induction motor generates AC voltage. In this case, the induction motor is used as a sensor to provide a low power signal. Because of the self-sensing mechanism, the fan works well for a certain period. Subsequently, it returns to the standstill mode and continue to monitor the pressure difference.We conducted experiments in a kitchen to test the theory. The kitchen had an exhaust fan with an airflow of 800 m3/h installed in the range hood. At the maximum exhaust setting, the room pressure decreased to -9.0 Pa. We fixed a ventilation fan with an airflow of 80 m3/h as the control ventilation fan. The room pressure was monitored using the induction motor. According to the specifications of the motor, a voltage more than 0.12 V implies that the pressure is below 3.0 Pa. In this case, the AC power supply was switched on by the circuit and aeration was performed for 10 seconds. After aeration, the fan entered standstill mode, and monitoring started. The results indicate that the proposed ventilation system worked well to increase the room pressure from -3.0 Pa to -1.2 or -1.5 Pa. Under non-aeration, the room pressure remained constant at -3.0 Pa.In summary, a self-sensor-based automatic aeration control ventilation system was proposed. The aeration fan itself was able to measure the subtle pressure decreases in the room, and we believe that such a system could eliminate the need for manual switching of aeration fans.

Suggested Citation

  • Tomomasa Yamasaki & Takashi Kaburagi & Toshiyuki Matsumoto & Satoshi Kumagai & Yosuke Kurihara & Yosuke Kurihara, 2020. "Automatic Control of a Room Ventilation System by a Single Fan Actuator," Proceedings of International Academic Conferences 10012462, International Institute of Social and Economic Sciences.
  • Handle: RePEc:sek:iacpro:10012462
    as

    Download full text from publisher

    File URL: https://iises.net/proceedings/iises-international-academic-conference-dubai/table-of-content/detail?cid=100&iid=020&rid=12462
    File Function: First version, 2020
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    Automatic ControlVentilationSelf-sensingMonitoringaerationPressure;

    JEL classification:

    • C67 - Mathematical and Quantitative Methods - - Mathematical Methods; Programming Models; Mathematical and Simulation Modeling - - - Input-Output Models

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:sek:iacpro:10012462. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Klara Cermakova (email available below). General contact details of provider: https://iises.net/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.