Performance Of Thermal Spray Coated Metallic Materials For Bio-Implant Applications

Author

Listed:
  • PRAVEEN KUMAR VERMA

    (Department of Mechanical Engineering, Punjabi University, Patiala 147002, India)

  • AMRINDER MEHTA

    (Research and Development Cell, Lovely Professional University, Phagwara 144411, India)

  • HITESH VASUDEV

    (School of Mechanical Engineering, Lovely Professional University, Phagwara 144411, India)

  • VINOD KUMAR

    (Department of Mechanical Engineering, Punjabi University, Patiala 147002, India)

Abstract

Metallic biomaterials are used to replace and rebuild human structural components due to their biocompatibility, corrosion resistance, and good mechanical properties. Biomedical metals have been used for 30 years. Medical implants use metallic biomaterials. Metallic biomaterials are needed to cure failed hard tissue, bone, and fractures. Because they’re strong, tough, and long-lasting. As the world population ages and seniors are more prone to experience hard tissue disintegration, there is a huge demand for improved metallic biomaterials. Titanium-based alloys, cobalt-based alloys, and stainless steel are feasible metallic biomaterials (316L). These biomaterials’ Young’s modulus should match that of human bones, reducing stress shielding. Implant designs include plates, rods, screws, and pins. Since the FDA approved these biocompatible metallic implants, orthopedic practices often employ them. Metals aren’t believable as biomaterials because they’re synthetic and have insufficient bio-functionality. The biocompatibility of metallic biomaterials must be considerably enhanced. Metallic biomaterials are often synthetic materials with no biological activity. The key issue is coating-to-substrate adhesion. Cover spalling from the substrate causes implant and tissue responses. Due to inadequate crystallization, the hydroxyapatite (HA) coating degrades, increasing implant failure risk by lowering titanium adhesion. Coated 316L stainless steel specimens have better adherence than untreated ones. The coating/substrate material, coating process, and coating thickness are thoroughly identified and discussed. The surface structure and microstructure of HA-based coating are explored to support the conclusions.

Suggested Citation

  • Praveen Kumar Verma & Amrinder Mehta & Hitesh Vasudev & Vinod Kumar, 2025. "Performance Of Thermal Spray Coated Metallic Materials For Bio-Implant Applications," Surface Review and Letters (SRL), World Scientific Publishing Co. Pte. Ltd., vol. 32(06), pages 1-15, June.
  • Handle: RePEc:wsi:srlxxx:v:32:y:2025:i:06:n:s0218625x23400127
    DOI: 10.1142/S0218625X23400127
    as

    Download full text from publisher

    File URL: http://www.worldscientific.com/doi/abs/10.1142/S0218625X23400127
    Download Restriction: Access to full text is restricted to subscribers

    File URL: https://libkey.io/10.1142/S0218625X23400127?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wsi:srlxxx:v:32:y:2025:i:06:n:s0218625x23400127. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Tai Tone Lim (email available below). General contact details of provider: http://www.worldscinet.com/srl/srl.shtml .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.