IDEAS home Printed from https://ideas.repec.org/a/wsi/srlxxx/v31y2024i03ns0218625x24500215.html
   My bibliography  Save this article

INFLUENCE OF MECHANICAL AND THE CORROSION CHARACTERISTICS ON THE SURFACE OF MAGNESIUM HYBRID NANOCOMPOSITES REINFORCED WITH HAp AND rGO AS BIODEGRADABLE IMPLANTS

Author

Listed:
  • VENKATA SATYA PRASAD SOMAYAJULA

    (Department of Mechanical Engineering, VNR Vignana Jyothi Institute of Engineering and Technology, Hyderabad, Telangana 500090, India†Department of Production and Industrial Engineering, National Institute of Technology, Jamshedpur, 831014 Jharkhand, India)

  • SHASHI BHUSHAN PRASAD

    (��Department of Production and Industrial Engineering, National Institute of Technology, Jamshedpur, 831014 Jharkhand, India)

  • SUBHASH SINGH

    (��Department of Mechanical and Automation Engineering, Indira Gandhi Delhi Technical University for Women, New Delhi, 110006 Delhi, India)

Abstract

Magnesium composites stay relevant for the applications of biodegradable implant as they are harmless and possess characteristics such as density and elastic modulus analogous to the cortical bone in humans. But corrosion is one major issue associated with magnesium when the biomedical applications are contemplated. Moreover, load bearing abilities are also required in case of an orthopedic implant. In this study, to achieve the desired implant characteristics, hybrid nanocomposites (HNCs) of Mg–2.5Zn binary alloys such as metal matrix, hydroxyapatite (HAp), and reduced graphene oxide (rGO) as reinforcements were fabricated via the vacuum-assisted stir casting method. The overall weight percentage of the reinforcements was fixed at 3% and both the reinforcements varied in compositions by weight to prepare the samples S0 (Pure Magnesium), S1 (Mg–2.5Zn–0.5HAp–2.5rGO), S2 (Mg–2.5Zn–1.0HAp–2.0rGO), S3 (Mg–2.5Zn–1.5HAp–1.5rGO), S4 (Mg–2.5Zn–2.0HAp–1.0rGO), and S5 (Mg–2.5Zn–2.5HAp–0.5rGO), respectively. The influence of mechanical characteristics such as tensile strength, compressive strength, and microhardness as well as the corrosion over the surface of the nanocomposite in simulated body fluid (SBF) have been assessed for their suitability as biodegradable orthopedic implants. Results suggest that the fabricated nanocomposites exhibit superior characteristics in comparison to pure magnesium. Increasing the HAp from 0.5 wt.% to 2.5 wt.% enhanced the compressive strength and reduced the corrosion rate. On the other hand, increasing the rGO from 0.5 wt.% to 1.5 wt.% increased the tensile strength. The formation of apatite layer over the composites is observed in the SBF solution. Among all the fabricated hybrid nanocomposite samples, the sample S3 (Mg–2.5Zn–1.5HAp–1.5rGO) with equal wt.% of HAp and rGO exhibited 209.60 MPa of ultimate tensile strength, 300.1 MPa of ultimate compressive strength, and a corrosion rate of 0.91 mm/year thus making it the best suited and a prospective material for biodegradable implant application.

Suggested Citation

  • Venkata Satya Prasad Somayajula & Shashi Bhushan Prasad & Subhash Singh, 2024. "INFLUENCE OF MECHANICAL AND THE CORROSION CHARACTERISTICS ON THE SURFACE OF MAGNESIUM HYBRID NANOCOMPOSITES REINFORCED WITH HAp AND rGO AS BIODEGRADABLE IMPLANTS," Surface Review and Letters (SRL), World Scientific Publishing Co. Pte. Ltd., vol. 31(03), pages 1-20, March.
  • Handle: RePEc:wsi:srlxxx:v:31:y:2024:i:03:n:s0218625x24500215
    DOI: 10.1142/S0218625X24500215
    as

    Download full text from publisher

    File URL: http://www.worldscientific.com/doi/abs/10.1142/S0218625X24500215
    Download Restriction: Access to full text is restricted to subscribers

    File URL: https://libkey.io/10.1142/S0218625X24500215?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wsi:srlxxx:v:31:y:2024:i:03:n:s0218625x24500215. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Tai Tone Lim (email available below). General contact details of provider: http://www.worldscinet.com/srl/srl.shtml .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.