Abstract

Aims and objectives To assess the consistency and safety of manual hyperinflation delivery by nurses of variable clinical experience using a resuscitator bag during physiotherapy treatment. Background Manual hyperinflation involves the delivery of larger than normal gas volumes to intubated patients and is routinely used by nurses in collaboration with physiotherapists for the management of retained sputum. The aim is to deliver slow deep breaths with an inspiratory hold without unsafe airway pressures, lung volumes or haemodynamic changes. In addition, nursing staff should be able to ‘feel' differences in resistance and adjust their technique accordingly. Design Prospective observational study utilising the simulation of a mechanically ventilated patient. Methods Thirty‐three nurses delivered manual hyperinflation to a SimMan3G mannequin who had three distinct lung scenarios applied (normal; asthma; Acute Respiratory Distress Syndrome) in randomised order during simulated physiotherapy treatment. Respiratory rate, tidal volume (Vt), mean inspiratory flow rate (Vt/Ti), and peak airway pressure data were generated. Results Over all scenarios, mean respiratory rate = 12·3 breaths/minute, mean Vt = 638·6 mls, mean inflation time = 1·3 seconds and peak airway pressure exceeded 40 cm H2O in 41% of breaths, although only in 10% of breaths during the ‘normal' lung scenario. Conclusions Experienced nurses were able to manually hyperinflate ‘normal' patients in a simulated setting safely. Despite their knowledge of barotrauma, unsafe airway pressures were delivered in some scenarios. Relevance to clinical practice Training with regard to safe airway pressures, breath hold and adequate volumes is recommended for all nurses undertaking the procedure. Nurses and physiotherapists must closely monitor the patient's condition during manual hyperinflation thereby recognising changes with regard to lung compliance and airway resistance, with nurses responding by altering their technique. The addition of a pressure manometer in the circuit may improve patient safety when performing manual hyperinflation.

Suggested Citation

  • Diane M Dennis & Christine N Duncan & Mary Pinder & Charley A Budgeon & Wendy J Jacob, 2016. "Performance of manual hyperinflation: consistency and modification of the technique by intensive care unit nurses during physiotherapy," Journal of Clinical Nursing, John Wiley & Sons, vol. 25(15-16), pages 2295-2304, August.
  • Handle: RePEc:wly:jocnur:v:25:y:2016:i:15-16:p:2295-2304
    DOI: 10.1111/jocn.13190
    as

    Download full text from publisher

    File URL: https://doi.org/10.1111/jocn.13190
    Download Restriction: no

    File URL: https://libkey.io/10.1111/jocn.13190?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wly:jocnur:v:25:y:2016:i:15-16:p:2295-2304. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Wiley Content Delivery (email available below). General contact details of provider: https://doi.org/10.1111/(ISSN)1365-2702 .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.