IDEAS home Printed from https://ideas.repec.org/a/wly/jocnur/v15y2006i2p162-167.html
   My bibliography  Save this article

A 4‐cm thermoactive viscoelastic foam pad on the operating room table to prevent pressure ulcer during cardiac surgery

Author

Listed:
  • Johanna Feuchtinger
  • Rob de Bie
  • Theo Dassen
  • Ruud Halfens

Abstract

Aims and objectives. In this experimental study, a 4‐cm thermoactive viscoelastic foam overlay and a heating source on the operating room table was compared with the standard operating room table with a heating source for the effect on the postoperative pressure ulcer incidence in cardiac surgery patients. Background. Pressure ulcer incidence in the cardiac surgery population is reported to be up to 29·5%. The prolonged compressive forces from lying on the operating room table are one source of pressure ulcer development in this population. Pressure‐reducing devices on the operating room (OR)‐table should reduce the patients’ interface pressure and thus the hazard of skin breakdown. Methods. A randomized controlled trial was performed to test the effect of a 4‐cm thermoactive viscoelastic foam overlay with a water‐filled warming mattress on the OR‐table (test OR‐table) compared with the standard OR‐table (a water‐filled warming mattress, no pressure‐reducing device) on the postoperative pressure ulcer incidence in cardiac surgery patients. Instruments. The pressure ulcer classification system of the European Pressure Ulcer Advisory Panel (EPUAP) was used for pressure ulcer grading. Results. The results show that patients lying on the 4‐cm thermoactive viscoelastic foam overlay suffer slightly more pressure ulcer (17·6%) than patients on the standard OR‐table without the foam overlay (11·1%). Because of the clinical relevance of the results, the randomized controlled trial was terminated after 175 patients at the interim analysis although the power calculation stated 350 patients. Conclusions. The combination of a 4‐cm viscoelastic foam overlay and a warming source cannot be recommended for pressure ulcer prevention on the operating room table. Relevance to clinical practice. Foam overlays are used to prevent pressure ulcers in patients. It is necessary to use such devices according to patient safety and use of resources.

Suggested Citation

  • Johanna Feuchtinger & Rob de Bie & Theo Dassen & Ruud Halfens, 2006. "A 4‐cm thermoactive viscoelastic foam pad on the operating room table to prevent pressure ulcer during cardiac surgery," Journal of Clinical Nursing, John Wiley & Sons, vol. 15(2), pages 162-167, February.
  • Handle: RePEc:wly:jocnur:v:15:y:2006:i:2:p:162-167
    DOI: 10.1111/j.1365-2702.2006.01293.x
    as

    Download full text from publisher

    File URL: https://doi.org/10.1111/j.1365-2702.2006.01293.x
    Download Restriction: no

    File URL: https://libkey.io/10.1111/j.1365-2702.2006.01293.x?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wly:jocnur:v:15:y:2006:i:2:p:162-167. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Wiley Content Delivery (email available below). General contact details of provider: https://doi.org/10.1111/(ISSN)1365-2702 .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.