IDEAS home Printed from https://ideas.repec.org/a/tec/techni/ojs3938.html

Experimental Comparison Between Wire Mesh and Electrical Capacitance Tomography Sensors to Predict a Two-Phase Flow Behaviour and Patterns in Inclined Pipe

Author

Listed:
  • Ali I. Hameed

    (Department of Mechanical Engineering, University of Zakho, Zakho City 12, Kurdistan Region of Iraq, Iraq)

  • Lokman A. Abdulkareem

    (Department of Petroleum Engineering, University of Zakho, Zakho City 12, Kurdistan Region of Iraq, Iraq)

  • Raid A. Mahmood

    (Department of Mechanical Engineering, University of Zakho, Zakho City 12, Kurdistan Region of Iraq, Iraq)

Abstract

Two-phase flow behaviour and its flow patterns have a significant effect in many applications in industry. Oil-gas is one of the two-phase flow types that have many applications in petroleum and power stations. An oil-gas two-phase flow behaviour and flow patterns have been investigated in an inclined pipe using two different tomography sensors: Wire Mesh sensor (WMS) and Electrical Capacitance Tomography (ECT). A special experimental facility was designed and built to operate the tow-phase flow application in the inclined pipe with the various angle of inclination. A set of experimental data were collected using operating conditions which covered a two-phase flow range of superficial velocity of gas (Usl) from 0.05 to 0.52 m/s and superficial velocity of liquid (Usg) from 0.05 to 4.7 m/s at atmospheric pressure and room temperature. Three inclined angles to change the pipe’s inclination 45, 60, and 80-degree were applied in the experiments. The Comparison between the Wire Mesh Sensor (WMS) and Electrical Capacitance Tomography (ECT) was completed experimentally. The results revealed that there is a good agreement between the two sensors, however; the WMS had a higher frequency which was calculated 1000 frames per second compared with the ECT which worked at 200 frames per second.

Suggested Citation

  • Ali I. Hameed & Lokman A. Abdulkareem & Raid A. Mahmood, 2021. "Experimental Comparison Between Wire Mesh and Electrical Capacitance Tomography Sensors to Predict a Two-Phase Flow Behaviour and Patterns in Inclined Pipe," Technium, Technium Science, vol. 3(5), pages 49-63, June.
  • Handle: RePEc:tec:techni:ojs:3938
    DOI: 10.47577/technium.v3i5.3938
    as

    Download full text from publisher

    File URL: https://techniumscience.com/index.php/technium/article/view/3938
    Download Restriction: no

    File URL: https://libkey.io/10.47577/technium.v3i5.3938?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:tec:techni:ojs:3938. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Ana Maria Golita (email available below). General contact details of provider: .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.